Laserfiche WebLink
<br />Form 400C-94 <br />Limited and Special Use Buildings <br /> <br />Project Name: <br />Address: <br />City, Zip Code: <br />Builder: <br />Owner: <br /> <br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />CHAPTER 4 - Commercial Bui/ding Compliance Methods <br />Administered by the Department of Community Affairs <br /> <br /> <br />ALL CLIMATE ZONES <br /> <br />.335"~C7 <br /> <br />Zone: <br />Building Classification: <br />Building Permit No,: <br />Permitting Office: <br />Jurisdiction No.: <br /> <br />~ <br />~S <br /> <br /> <br /> BUILDING INFORMATION <br />WALLS ROOF/CEILING FLOORS DOORS GLASS <br />TYPE U AREA TYPE ~U I AREA TYPE U AREA TYPE U AREA TYPE U AREA <br />Concrete (CBS) Under Attic ..~I 7.z.z.. Slab-an-grade C! ~f#5" Wood Single, wall <br />Wood frame Single Assembly I I Raised Wood Metal Double, wall . '8/ 15 <br />Metal frame .13~ RIO Other: I I Raised Concrete Insulated ,II'} #'t. Single, roof <br />Insulation R-value II Insulation R-value I/VI Insulation R-value Other Double roof <br /> <br /> SYSTEMS INFORMATION <br />AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUlH 'TYPE <br />Unitary & Heat Pump Central & Heat Pump '::Iectric <br /><65,000 Btu/h SEER - <65,000 Btu/h - HSPF - Resistance 0 <br />~65.000 Btu/h 1~..rEER - IPLV - ~65,000 Btu/h - COP - Dedicated Heat Pump 0 <br />Water cooled - EER - IPLV - Water cooled - COP - Gas <br />Evaporatively cooled - EER - Evaporatively cooled - COP - Natural 0 <br />PTAC - EER -- Electric Resistance - COP - LPG 0 <br />Chiller - COP - IPLV - Gas/Oil (cirlce one) HRU 0 <br />Other: - - - <225.000/300,000 Btu/h - AFUE - Other: 0 <br /> ~225,000/300.000 Btu/h E. <br />LIGHTING Total Lighting Wattage 1"00 2.1/1 I SIZING CALCULATION El I DUCTS R-value <br /> = = ~.O <br />Total Conditioned Floor Area ~ (,5'" Watts/sq.ft. Attached <br /> <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded bv all buildinas.) <br />Components Section Requirements Check <br />Windows 406,1 Maximum of .37 cfm per linear foot of operable sash crack, v <br />Doors 406,1 Maximum of 1,25 cfm per square foot of door area, or <br />Joints/Cracks 406,1 To be caulked, gasketed. weatherstripped or otherwise sealed. ,/ <br />Reheat 407.1 Electric resistance reheat prohibited, ....- <br />Ventilation 409,1 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. ....... <br />HVAC Efficiency 407,1.408,1 Minimum efficiencies - Heatinq: Tables 4-7,4-8.4-9. Coolinq: Tables 4-3,4-4,4-5,4-6, y <br />Transport Enerqy 410.1 Minimum of 8.0. ,/ <br />Balancinq 410.1 HVAC distribution system(~ tested and balanced. ... <br />HVAC Controls 407.1 Separate readily accessible manual or automatic thermostat for each system. or <br />HVAC Ducts 410,1 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attachecl. sealed. insulated <br /> and installed in accordance with the criteria of section 410,1, v <br />Operations Manual 102.1 Operations manual will be provided to owner. v <br />Pipinq insulation 411.1 In accordance with Table 4-11, ,/ <br />Water heaters 412,1 Automatic electric storage water heaters <;120 gallons and gas & oil fired storage water heaters $75.000 Btu/h shall <br /> meet performance requirements in Table 4-12. Electric >120 gallons: standby loss $.30+27NT Gas> 75,000, ./ <br /> Oil >105,000: Et ,78. Standby loss <; 1.30+114NT Gas, Oil >155,000: Et .78. Standby loss $ 1:30+95NT' <br />Swimming Pools 412,1 Spas & heated pools must have covers, Non-commercial pools must have pump timer. Gas spa & pool heaters must <br />& Spas have a minimum thermal efficiency of 78%, <br />Hot Water Pipe 412,1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first 8' of pipe from a storage <br />Insulation tank, <br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2,5 gpm at 80 psi, Toilets maximum 3.5 gallon/flush, Public lavatory <br /> fixture maximum flow of .5 gpm; or if self-closing valve, .25 gallon circulating, ,5 gallon non-circulating. <br />Liqhtinq 415,1 Ballast Efficacy Factors (BEF) shall meet the levels in Table 4-15, V' <br /> <br />If required by Florida law. I hereby certify that the system design is in compliance with the Florida Energy Code. <br />ARCHITECT: <br />ELECTRICAL SYSTEM DESIGNER: <br />LIGHTING SYSTEM DESIGNER: <br />MECHANICAL SYSTEM DESIGNER: <br />PLUMBING SYSTEM DESIGNER: <br /> <br /> <br />Registration No. <br /> <br />"---------- -._-- --.. ---._--- <br /> <br />~--._- ---- -.-.-------- <br /> <br />Y.#e:lOhOd1~ <br /> <br />~om Ii nce with Chapter 4 was demonstratedoa Prescriptive Measures methodology: <br />Detached commencal buildings Skyboxes or sports stadium buildings <br />less than 100 square feet that are used seasonally <br /> <br /> <br />D TraffiC safety <br />control towers <br /> <br />D Supermarkets <br /> <br />I hereby certify that the plan <br />compliance with the Flor' <br />PREPARED BY: <br />I hereby certify that this <br />OWNER AGENT: <br /> <br />red by the calculation are in Review of plans and specifications covered by this calculation indicates compliance <br />. _with the Florida Energy Code <br />DATE: C, -3-~ inspected for compliance <br />Florida Energy Code BUILDING OlIC~ <br />DATE: DATE:... __ <br /> <br />