My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
95-5001
Zephyrhills
>
Building Department
>
Permits
>
1995
>
95-5001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 12:02:05 PM
Creation date
6/26/2006 8:18:06 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
95-5001
Building Department - Name
BOLENDER,JOHN
Address
38461 HWY 54E
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
5
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />PRESCRIPTIVE REQUIREMENTS LIST* <br /> <br />-'> <br /> <br />- <br />METHOD C CRECK <br />Detached Commercial Buildings Less than 100 sq.ft. <br />Glass Area: No limit. ./ <br />Overhang: Minimum 1 foot if not under another structure; or y <br /> No overhang with a glazing Shading Coefficient of 0,55 or less. >" <br />Walls: Minimum insulation level <br /> Frame walls - R-11. V <br /> Masonry walls - R-5, V" <br />Roofs/Ceilings: Minimum insulation level- R-19. r/' <br />Floors: Minimum insulation level - None. /" <br />Cooling System: Code minimums as per section 407.1.ABC,3. / <br />Heating System: Code minimums as per section 408.1.ABC.3. ,/ <br />Skyboxes or Sports Stadiums <br />Glass: No limit with glazing Shading Coefficient of 0,55 or less. ./ <br />Overhang: None required, '" <br />Walls: Minimum insulation level <br /> Frame walls - R-11, V' <br /> Masonry walls - R-5. <br />Roofs/Ceilings: Minimum insulation level- R-19. V' <br />Floors: Minimum insulation level <br /> Frame floor- R-19, -- <br /> Concrete floor - None, ,/ <br />Cooling System: Minimum equipment efficiency requirements ,/ <br /> Air cooled - 10,0 EER or 10,5 SEER. <br /> Water cooled - 11.0 EER. <br />Heating System: Code minimums as per section 408,1,ABC.3, <br />Air Distribution A programmable setback shall be installed for in-season use; <br />System: At least one humidistat control per zone shall be installed for off-season use. <br /> EXCEPTION: Installation of a central energy management system, <br />Lighting: Total connected wattage shall not exceed .4 watts per square foot of conditioned space. - <br />Traffic Safety Control Towers <br />Glass: No limit. <br />Overhang: Minimum 1 foot if not under another structure; or <br /> No overhang with a glazing Shading Coefficient of 0.55 or less, <br />Walls: Minimum insulation level <br /> Frame walls - R-11, <br /> Masonry walls - R-5, y'" <br />Roofs/Ceilings: Minimum insulation level- R-19, ,/ <br />Floors: Minimum insulation level - None, p <br />Cooling System: Code minimums as per section 407,1,ABC.3. ./ <br />Heating System: Code minimums as per section 408,1,ABC,3, <br />Lighting: Total connected wattage shall not exceed 2,1 watts per square foot of conditioned space. <br />Supermarkets <br />Glass: No limit. <br />Overhang: None required, <br />Walls: Minimum insulation level - R-5. <br />Roofs/Ceilings: Minimum insulation level- R-10, <br />Floors: Minimum insulation level <br /> Raised floors - R-3, <br /> Slab-on-grade floors - None, <br />Cooling System: Air cooled - 10,0 EER <br /> Water cooled - 11,0 EER, <br />Heating System: Code minimums as per section 408.1 ,ABC,3, <br />Lighting: Total connected wattage shall not exceed 2.3 watts per square foot of conditioned space, <br /> <br />FORM 400C 94 <br /> <br />*AII Basic Prescriptive Requirements, designated in the Code by ".l.ABC" and <br />summarized on the front of this form, must also be met. <br />
The URL can be used to link to this page
Your browser does not support the video tag.