<br />Climate Zanes 4' 5 6
<br />
<br />TABLE &C.1 : PRESCRIPTIVE REOUIREMENTS FOR SMALL ADDITIONS (600 Sq, Fland Lell), RENOVATIONS TO EXISTING BUILDINGS AND SITE-lNSTALLED COMPONENTS OF MANUFACTURED HOMES
<br />
<br /> MINIMUM INSULATION
<br /> COMPONENT INSULATION tNST ALLED
<br /> Cancrete R-5 'RS'
<br />~ Frame, 2' x 4' R.11
<br />...I Frame, 2' x 6' R-19
<br />~ Camman, Frame R.11
<br /> Camman, Masanry R.3
<br />~ Under Attic R-30 R-3o
<br />z Single Assembly; enclased R.19
<br />;:j
<br />W S.ingle Assembly; Opened R-10
<br />u Cammon, Frame R-11
<br />UJ Slab-on.grade No. Minimum 0
<br />a:: Raised Waad R.11
<br />9 Raised Cancrete R.5
<br />LL Camman, Frame R.11
<br />I- "l2.-(.
<br />u In unconditioned space R-6
<br />:l
<br />0 In conditioned space No minimum
<br />
<br /> MINIMUM INSTALLED
<br /> EQUIPMENT EFFICIENCY EFFICIENCY
<br />i Central AlC . Splll SEER '" 10.0 SEER 10
<br /> -
<br />:J .Single Pkg, SEER '" 9,7 a~!:A '"
<br />~ -
<br />Room unit or PT AC EER 8,5" i:EA '"
<br /> . . -
<br /> Electric Resistance ANY
<br />i Heat pump. Spill HSPF '" 6,8 HSPF II ~
<br />~ . Single Pkg, HSPF '" 6,6 HSPF . -
<br />:I: Room unit ar PTHP COP '" 2,7" HSPFI Ii
<br />~ -
<br /> COP
<br />a.. Gas, natural ar propane
<br />U) AFUE '" .78 AFUE '"
<br /> -
<br /> Fuel Oil AFUE '" .78 AFUE '" -
<br />a: Electric Resistance EF '" ,88 EF...'
<br />...~ -
<br />~~ Gas; Natural ar L.P. EF '" .54 EF .. -
<br /> Fuel Oil EF '" .54 EF ..
<br />
<br />"See Table 6.3. 6.7
<br />
<br />TABLE 6C-2: PRESCRIPTIVE Rl:QUIREMENTS FOR GLASS AREAS IN ADDITIONS ONLY
<br />
<br />Maximum percentage glass to lloar area allowed is selected by type, overhang length, and shading coefticient. Maxlmum% = Installed % -
<br />GLASS TYPE, OVERHANG, AND SHADING COEFFICIENT REQUIRED FOR GLASS PERCENT AGE ALLOWED
<br />UP TO 20% UP TO 30% UP TO 40% UP TO 50%
<br />Single Double Single Double Single Double Single Double
<br />OH.SC OH.SC OH-SC OH.SC OH-SC OH.SC OH-SC OH-SC
<br />1'-1,0 0'. ,90 2'.1,0 1', ,90 3'- 1,0 2'. ,90 4'.1,0 3'. .90
<br />0'- .86 1'- _86 0'. .70 2'. ,86 .. 1'. ,70 3'. ,86 2'. .70
<br /> 0'. .65 1'. ,65 0'. ,50 2'. ,65 1'- .50
<br /> 0'- ,45 1'- ,45 0'. ,40
<br /> 0'. ,35 "
<br />Shading coefficients (SC) may be obtained from the manulacturer, Single clear SC = 1,0, double clear SC = .90, and single tint SC .. .86.
<br />TABLE 6C-3 I MINIMUM REQUIREMENTS FOR ALL PACKAGES
<br />COMPONENTS SECTION REQUtREMENTS CHECK
<br />Exterlar Jo.lnts & Cracks 606,1 To be caulked, gasketed, weather-stripped or otherwise sealed, V
<br />Interlar Jalnts & Cracks 606,1 All openings In interior surfaces af ceilings and exterior walls must be sealed. \;""
<br />Sale & Tap Plates 606,1 Sole plates amI penetrations tnrougn top plates of exterior walls mustoe sealeif, ..vI\-
<br />Inflltratlan BarrIer 606,1 Infiltration barrier must be Installed in exterior walls 8. raiseif wood floors. .........-
<br />Fireplaces 606.1 Fireplaces must have flue dampers, glass doors and outside combustion air intakes, 1>JA.
<br />Exhaust Fans 606,1 Exhaust fans vented to unconditioned space shall have dampers, except for combustion
<br /> devices with integral exhaust ductwork, Nit
<br />Cambustlo.n 606,1 Combustion space and water heating systems must be provided with outside combustion air,
<br />Heating except for direct vent appliances, -Ur
<br />Water Heaters 612,1 Compty with efficiency requirements in Table 6,", Switch or clearly marked circuit breaker (electric)
<br /> or cutoff (gas) must be provided, External or buill-in heat trap required, /<J1'r
<br />SwimmIng 612.1 Spas & heated pools must have covers (except solar heated), Non-commercial pools must have a
<br />Po.o.ls & Spas pump timer. Gas spa & pool heaters must have minimum thermal efficiency 01 78%, foJfr
<br />Hat Water PIpes 612,1 Insulation is required for hot water circulating systems, (including heat recovery units) and the first NA
<br /> , 8' of piping from the water heater (or until piping enters an Insulated wall or slab).
<br />Sho.wer Heads 612,1 Waler flow must be restricted to no more than 3 gallons per minute at 80 PSIG, Nit
<br />HV AC Duct 610,1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached,
<br />Canstructlan, sealed, insulated and Installed in accordance with the criteria of Section 610,1, Ducts in attics must be ./
<br />Insulation & Installatlo.n insulated to a minimum of R-6, Air handlers shall not be installed in attics unless in mechanical closets,
<br />HV AC Co.ntrals 607,1 Separate readily accessible manual or automatic thermostat lor each system, ,.JA-
<br />
<br />GENERAL DIRECTIONS:
<br />1. On Table 6C.l ind'lCale the R.value of \he insulation being added to each component and the enlciency levels 01 the equipment being instaBed, All R,valueS and elficiencles inslaned must meet or exceed the minimum values
<br />fisted, Components and equipment neither being added nor renovated may be left blank,
<br />2, ADDITIONS ONLY, Determine \he percentage of ~ gtass.lo conditioned floor area in \he addition as Iollows, To1al\he areas 01 all glass windows. sliding glass doors and glass door panels, DcuIlIo \he .rea of aft non,
<br />vertical rool glass and add " to the previous total. When glass In existing exterior wans is being removed or enclosed by \he addition. an amount equal to the to1al area oIlhis glass may be subtracted !rom \he IOlal glass area,
<br />Divide the adjusted glass area total by \he concItioned floor area 01 \he addition, Multiply by 100 to get the percent, Find the largest glass percentage under whiCh your calculated percentage 'altt On Table 6C,2, PraSCriptives I
<br />are given by the type 01 glass (Single or Double pane) and \he ovemang (00) paired with a shading coeIIicient (SC), For a given glass type and overhang, \he minimum shading coell'ocient allowed is specified, AClua' glass
<br />windows and doors previously In tha exterior wans 01 the house and being rainstaned In the addition. do not have to comply with the ovemang and shading coelf'lcient requirements on Table 6C,2. AI new glass in the addition
<br />must meelthe requlrement for one 01 the options In the glass percentage category you 1ndicaIed, The overhang (00) distance is measured perpendicularly trom the lace of \he glad 10 . point directly under \he outermost edge
<br />of \he ovemang,
<br />3, RENOVATIONS ONLY, Replacemenl glass needs to meet the tollowing requirements, Any glass type and shading coefficient may be used for glass areas which are under at least a Iwo loot ovemanil and whose lowest
<br />edge does not extend further than Bleet Irom \he overhang, Glass areas being renovated that do not meet this criteria musl be either single,pane tinted. doubIe'pane clear or double,pane tinted,
<br />4, Complete the Inlormation requested on :he top hall of page 1,
<br />5, Read -Minimum Requirements for Small Additions and Renovations', Table 6C,3. and check all applicable items,
<br />6, Read. sign and date the "Owner/Agent" certification ~atement on page 1,