Laserfiche WebLink
<br />609 Series Air Duct Smoke Detectors <br /> <br />Table 4: Contents of Pre-packaged Duct Detector Models <br /> <br />Pre-packaged Model Number <br />609U01 <br />609U02 <br />609U01,11 <br />609U02-11 <br />---- <br />609U01-24 <br /> <br />609U02-24 <br /> <br />1---- 611 UD Photoelectronic <br /> <br />G09U24 1 <br />609U24 <br />---- <br /> <br />611 UD Photoelectronic 609U31, <br />--- -,...---,- u____ _ --- -, -'--_______, __.... ..___...__,...1 <br /> <br />Ji <br />_=::::J <br /> <br />609U01-31 <br /> <br />609U02-31 <br /> <br />612UD Ionization <br /> <br />612UD Ionization <br /> <br />609U31 <br /> <br />1_ For electrical specifications of function cards, see Tables on previous pages, <br /> <br />Accessories <br /> <br />All function cards provide for remote alarm indicator and/or remote <br />test capability when used in conjunction with the ESL 606 Series <br />accesories: Model 606U1 Remote Alarm Indicator or Model 606U2 <br />Remote Test and Alarm Indicator, All four-wire function cards <br />include an extra terminal to facilitate connection of a local or remote <br />detector alarm reset switch for use with the ESL Model 609URS <br />Reset Switch or Model 606U3 Remote Alarm Indicator with Remote <br />Test and Reset. See Table below for additional accessories, <br /> <br />-- - <br /> <br />Description <br /> <br />Remote Indicator <br /> <br />Remote Indicator with Keyed Remote Test <br /> <br />Remote Indicator with Keyed Remote Test <br />and Reset <br /> <br />Inlet Sampling Tube Extension-2 ft. <br />Inlet Sampling Tube Extension-4 ft. <br />-- <br />Inlet Sampling Tube Extension-S ft. <br />Test Tool <br /> <br />Powel Supervision Unit 12 VDC systems <br />Power Supervision Unit 220 V AC systems <br />Local Reset Switch, N/C with 6" Leads <br /> <br />Replacement Parts <br />r __~~~el Number '-___ Descrlpt~on__,___J <br />620010228 Foam Filter] <br />~-------._------_.__._.__.- -----------------.-- . <br /> <br />672200068 Round Duct Mounting Gasket <br /> <br />66S090S4A <br /> <br />Relay - 10 Amp <br /> <br />Sentrol, Inc. <br />Corporate Headquarters: <br />12345 SW Leveton Drive <br />Tualatin, OR 97062 <br />503-692-4052 <br />Technical Suppa"': 800-648,7424 <br />Bulletin 2269-8S6 December 1994 U.S. and Can..da: 800-547.2556 <br />Appearances and details subject to change without notice, <br /> <br />t:5l: <br /> <br />A Product of Sentrol, Inc. <br /> <br />PRODUCT DATA <br />Dimensions: <br />Length: 16,5 in, (42 cm) <br />Width: 5,5 in, (14 cm) <br />Depth: 4,0 in, (10 cm) <br />Integral sampling tubes extend the width by 5,5 inches and require two <br />holes of 2 inches diameter for clearance <br />Weight: ," <br />Maximum weight is 7S,75 oz, (2,23 kg,) <br />Operating Temperature Range: <br />0-50aC, 32-1200F <br />Operating Duct Air Velocity Range: <br />300-2000 fl./min, when the 612UD is installed within the duct hOllsing <br />300-4000 ft./min, when the 611 UD is installed within the duct housing <br /> <br />SPECIFICA TrONS <br />This Air Duct Detector shall be either an ESL Model 609U01 Photoelec- <br />tronic Detector, Enclosure assembly or an ESL Model609U02 Ionization <br />Detector, Enclosure assembly, <br /> <br />The base of the enclosure and the manifold shall be constructed of solid <br />structural foam, and shall incorporate an air-tight smoke chamber in <br />compliance with UL268A, Standard for Smoke Detectors for Duct Appli- <br />cations, The detector enclosure shall be equipped with an integral <br />mounting base capable of accomodating either a photelectronic or ioniza- <br />tion detector head and shall be capable of local testing via a magnetic <br />switch, The clear covers for the enclosure shall be constructed of Lexan,@ <br /> <br />The detector shall operate at air velocities of aDO feet per minute to 2000 <br />feet per minute utilizing a 612UD sensing head, and 300 - 4000 feet per. <br />minute utilizing a 611 UD sensing head, The duct detector shall be <br />capable of interfacing directly with ESL 606 Series Remote Stations. <br />which shall provide for local alarm indication and test functions, Local or <br />Remote Reset capability shall be provided for utilizing the Models <br />609URS or 606U3 respectively, <br /> <br />An integral filter system shall be included to reduce dust and residue <br />accumulation which could cause adverse effects on the sensing head <br />and the enclosure, A UNIOUE air flow monitor shall be included to <br />indicate the presence of air flow through the detector, Air duct detector <br />shall comply with the requirements of UL268A without the attachment of <br />any sampling inlet or exhaust tube(s), Extension sampling tubes, where <br />required, shall be easily installed after the housing is mounted to the duct <br />by passing them through the duct detector enclosure, <br /> <br />Distributed By: <br />