<br />EQUIPMENT <br /> <br />The ESL 609 Series Air Duct Smoke Detector consists of three <br />primary elements: a) the sensing head, b) the selected function <br />card, and c) a housing for the detector and function card, <br /> <br />Duct Detector Housing <br /> <br />The base section of the housing that mounts to the duct wall <br />includes: a) integral inlet and exhaust sampling tubes, b) a <br />sensing head mounting base with an automatic-opening continu- <br />ity switch, c) a conduit connection plate with ground screw, d) the <br />detector cover/manifold monitor, and e) the function card com, <br />partment cover. <br /> <br />The 609U01 is an air duct detector enclosure supplied with a <br />611 UD photoelectronic smoke sensing head, The 609U02 is <br />supplied with a 612UD ionization smoke sensing head, <br /> <br />Electrical Function Cards <br /> <br />Any ofthe function cards may be used with the Models 609UO 1 and <br />609U02 duct detector assemblies, All function cards include a <br />local alarm (red) indicator, local test capability, and provision for <br />remote test and remote alarm indicator connections, All models <br />except 609U10 include a remote detector reset capability, All <br />models with auxiliary alarm contacts are Listed as suitable for <br />releasing service applications, <br /> <br />Two-Wire Applications <br /> <br />Three function cards are currently available for two,wire alarm <br />initiating use, Two-wire detectors must be connected to Listed <br />compatible initiating circuits. Two-wire function cards do not in- <br />clude a power-on LED (green), Electrical specifications are shown <br />in Table 1, below, <br /> <br />Tabte1: Electrical Specifications - Two-Wire Function Card Application, Low Voltage DC <br /> <br />:',., ~ "~ti;of-h:;":'i: ~~~p~'~:!!,..:! :"'~;~'. ,Vottage i : Voltage 'Alarm <br />:"M0d8I1' Compatibility Standby Alarm <br />. Ii' , Range ,: ,Range Current Contacts 1 <br />'.,~~~bttr. ' f~b Identifier" ~ Current <br />_~. "~'l ~''''.~''~' ';' ;io~~f! ::;,', ),\,,.,,," Sta.ndby '!:!,Alarm , <br />609U10 SOD 8,5-44 VDC 33 VDC max, 50 uA max, 60 mA max. None <br />609U1l 502 B.5-44 VDC 33 VDC max, 50 uA max, 60 mA max, lA, lC (2 Amp) <br /> 2 <br />609U12 536 8,5-44 VDC 33 VDC max, 50 uA max, 70 mA max, 1A (2 Amp), 2C (10 Amp) <br /> <br />1, Relay contact ratings shown are for a resistive load at 30 VDC or 120 VAC maximum, <br /> <br />2, When the Model609U12 function card is used in a two-wire initiating circuit application. the 10 ampere relay must NOT be programmed <br />for normally operated releasing service, If the relay were to be programmed in this manner, the standby operating current would be <br />increased from 50 microamperes to 10 milliamperes, <br /> <br />Low Voltage, Four-Wire Applications <br /> <br />Seven function cards are currently available for low-voltage, four- <br />wire alarm initiating and releasing service use, or stand-alone <br />releasing service applications, All of the low voltage four-wire <br />function cards can be powered from a nominal 24 VAC source, <br />available in many HV AC applications, Electrical specifications <br />are shown in Table 2, on the following page, <br /> <br />Line or Low Voltage, Four-Wire Applications <br /> <br />Four function cards are currently available for line voltage (i,e" <br />120 V AC nominal), four-wire alarm operation, All four function <br />cards can be field modified for low voltage, four-wire opera- <br />tion by cutting Jumper J12 located In the upper right-hand <br />comer of the function card, below terminals 0 and 1. Four- <br />wire LinelLow voltage function cards INCLUDE a power-On LED <br />(green), Electrical specifications are shown in Table 3, on the <br />following page, <br /> <br />220/240 V AC Function Card <br /> <br />The Model609U25 function card is currently the only function card <br />available for 220/240 VAC, four-wire operation, Electrical speci- <br />fications are shown in Table 3, on the following page, . <br /> <br />Field Programming of the 10 Ampere Contacts for Releasing <br />Service. <br /> <br />As supplied, the two, 10 Ampere rated, Form C auxiliary contacts <br />provided with function cards 609U12, 609U14, 609U22, 609U24. <br />609U25, 609U32. and 609U34 transfer on alarm ONLY, The relay <br />that controls these contacts may be field programmed, by moving <br />jumper J10 from pin PB to P7, to be energized in the normal <br />standby condition, so that the contacts transfer on removal of the <br />sensing head, loss of power to the air duct detector assembly, or <br />alarm of the sensing head, This may be desirable in many <br />releasing service applications, <br />