<br />SUMMER POINT MULTIPLIERS (SPM) <br /> <br />~r <br />tia: <br />~[ <br /> <br />6A-1 SUMMER OYERHANG FACTORS (SOFI FOR SINGLE AND DOUBLE PANE GLASS. <br />OH RATIO .00-.11 .12-.17 .18-.26 .27-.35 .36-.46 .47-.57 .58-.70 .71-.83 <br />N 1.00 .94 .91 .87 .83 .79 .75 .72 <br />NE/NW 1.00 .94 .91 .85 .79 .72 .68 .63 <br />EIW 1.00 .95 .92 .85 .78 .70 .64 .58 <br />SE/SW 1.00 .93 .90 .81 .72 .62 .55 .49 <br />S 1.00 .91 .87 .77 .67 .57 .50 .45 <br />OH lENGTH' 0 ft 1 ft 1'h ft 2 ft. 3 ft. 3V.ft 41;; ft 5V. ft. <br />'To select bv Ovemano Lenattt no oart of alass shall be more than 8 ft. below the overhana. <br /> <br /> CLIMATE ZONES 4 5 6 <br />.84-1.18 1.19-1.72 1.73-2.73 2.74+ <br />.69 .62 .56 .50 <br />.58 .50 .40 .36 <br />.52 .42 .33 .26 <br />.42 .33 .27 .22 <br />.39 .32 .28 .25 <br />Sv.ft. Q1j,ft 14ft -.20 ft. + <br /> <br />6A-2 WALL SUMMER POINT MULTIPLIERS SPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.4 2.2 <br />2.3 .8 <br />1.9 .7 <br />1.7 .6 <br />1.0 .3 <br />.6 .2 <br /> <br />R-YALUE <br />0-6.9 <br />7-10.9 <br />11-12.9 <br />13-18.9 <br />19-25.9 <br />26& U <br /> <br /> <br /> <br />CONCRETE BLOCK' <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />2.5 .9 <br />1.4 .7 <br />1.0 .6 <br />.8 .4 <br />.4 .3 <br />.2 .2 <br />.1 .1 <br /> <br />STEEL <br />EXT ADJ <br />8.9 2.9 <br />4.1 1.3 <br />3.0 1.0 <br />2.8 0.9 <br />2.4 0.8 <br />1.3 0.4 <br /> <br />6A-3 DOOR SUMMER POINT MULTIPLIERS 6A-4 CEILING SUMMER POINT MULTIPLIERS (SPMI <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF <br /> R-YALUE SPM R-YALUE SPM CEILING TYPE <br />WOOD 7.2 2.4 19-21.9 1.1 10-10.9 3.0 R-YALUE DROPPED EXPOSED <br /> 22-25.9 .9 11-12.9 2.7 10-13.9 3.0 3.3 <br />INSULATED 4.8 1.6 26-29.9 .7 13-18.9 2.4 14-20.9 2.0 2.1 <br /> 30-37.9 .6 19-25.9 1.8 21 & Up 1.4 1.3 <br /> 38 & Ua .4 26-29.9 1.1 <br /> ~O R. Un OQ <br />6A-5 FLOOR SUMMER POINT MULTIPLIERS (SPMI <br />SLAB-ON-GRADE ',t:11f RAISED RAISED WOO[)2 <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wI UNDER ADJ~CENT <br />un CONSTRUCTION FLOOR INSULATION <br />R-YALUE SPM iif. R-YALUE SPM R-YALUE SPM SPM SPM <br />0-2.9 -31.9 0-2.9 -1.0 0-6.9 0.9 -~j.8 5.3 <br />3-4.9 -31.8 3-4.9 -1.7 7-10.9 -1.1 -2.8 2.1 <br />5-6.9 -31.7 5-6.9 -1.7 11-18.9 -to -2.2 1.8 <br />7R.IJn -~11l [Ii' 7 R. Un -17 ii 1Q R. Un -OQ -1.8 1.0 <br /> <br />SPM) <br /> <br /> 6A-? DUCT MULTIPLIERS (OM) <br /> RETURN DUCTS RETURN DUCTS <br /> R-YALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE <br /> SUPPLY DUCTS IN 4.2-5.9 1.14 1.10 <br /> UNCONDITIONED SPACE 6.0-6.6 1.10 1.07 <br /> 6.7 & Ua 1.09 1.06 <br /> SUPPLY DUCTS IN 4.2-5.9 1.10 1.00 <br /> CONDITIONED SPACE3 6.0-6.6 1.07 1.00 <br /> fl. 7 & Un LOll 1.00 <br />6A-8 COOLING SYSTEM MULTIPLIERS (CSMI <br />SYSTEM TYPE COOLING SYSTEM MULTIPLIERS lCSMI <br />Central Units (SEER) Rating 7.5-7.9 8.0-8.4 8.5-8.8 8.9-9.4 9.5-9.9 10.0-10.4 10.5-10.9 11.0-11.4 11.5-11.9 12.0-12.4 <br />CSM .45 .43 .40 '. .38 .36 .34 .32 .31 .30 .28 <br />PTAC & Room Units (EER) Rating 12.5-12.9 13.0-13.4 13.5-13.9 14.0-14.4 14.5-14.9 15.0-15.4 15.5-15.9 16.0-16.4 16.5-16.9 17.0-17.4 17.5 & Ua <br />CSM .27 .26 .25 .24 .24 .23 .22 .21 .21 .20 .19 <br />MINIMUMS: CENTRAL UNITS-AIR COOLED SPLIT SYSTEM 10.0 SEER, SINGLE PKG. 9.7 SEER, GROUND WATER HEAT PUMP 11.0 EER. PTAC--SEE TABLE 6-2 <br /> <br />6A-6 INFILTRATION SUMMER POINT MULTIPLIERS (SPM) <br />INFILTRATION PRACTICE SPM <br />SEE TABLE 6A-21 <br />PRACTICE #1 13.8 <br />PRACTICE #2 10.9 <br /> <br />6A-9 HOT WATER MULTIPLIERS (HWMI <br />SYSTEM TYPE HOT WATER MULTIPLIERS lHWM <br />'. EF .80-.81 .82-.83 .84-.85 .86-.87 .88-.90 .91-.93 .94-.96 .97 & Up <br />Electric ResistanCe HWM 3879 3785 3695 3609 3527 3411 3302 3200 <br />Natural Gas EF .43-.47 I .48-.49 .50-.51 .52-.53 .54-.55 .56-.57 .58-.59 .60-.61 .62-.63 .64-.65 .66 & Up <br />HWM 2974 I 2664 2558 2459 2368 2284 2205 2132 2063 1998 1938 <br />LP Gas HWM 3638 I 3259 3129 3009 2897 2794 2697 2607 2523 2444 2370 <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />-3. <br />