Laserfiche WebLink
<br />WINTER POINT MULTIPLIERS (WPM) <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />6A.10 WINTER OYERHANG FACTORS (WOF) <br />J OH RATIO .00-.11 I .12-.17 .18-.26 .27-.35 I .36-.46 I .47-.57 .58-.70 .71-.83 I .84-1.18 1.19-1.72l1.73-2.73 T 2.74+ <br /> SINGLE PANE GLASS <br />N 1.00 1.03 1.05 1.08 1.10 1.13 1.15 1.18 1.20 1.24 1.29 1.34 <br />N8NW 1.00 1.07 1.10 1.15 1.20 1.25 1.30 1.35 1.39 1.50 1.59 1.67 <br />ENJ 1.00 .71 .57 .19 -.20 -.65 -1.05 -1.48 -2.03 -3.01 -4.06 -5.04 <br />SElSW 1.00 .93 .90 .80 .68 .54 .39 .22 .05 -.33 -.71 -1.01 <br />tia: S 1.00 .95 .92 .83 .70 .54 .36 .13 -.13 -.70 -.98 -1.09 <br />~l DOUBLE PANE GLASS <br />N 1.00 1.05 1.07 1.11 1.14 1.18 1.21 1.24 1.28 1.34 1.40 1.47 <br />NElNW 1.00 1.11 1.16 1.24 1.32 1.41 1.48 1.56 1.63 1.80 1.94 2.08 <br />ENJ 1.00 .88 .82 .66 .50 .31 .15 -.03 -.26 -.66 -1.10 -1.50 <br />S8SW 1.00 .95 .92 .85 .76 .65 .54 .41 .28 -.01 -.30 -.52 <br />S 1.00 .96 .94 .87 .78 .65 .51 .33 .13 -.30 -.51 -.60 <br />OH LENGTH* Oft. 1 ft. 1%ft. 2ft. 3ft. 3% ft. 4'/2 ft. 5% ft. 6% ft. 9Y,ft. 14ft. 20ft.+ <br /> 'TO SELECT BY OVERHANG LENGTH. NO PART OF GLASS SHALL BE MORE THAN 8 FT. BELOW THE OVERHANG. <br /> <br />6A.11 WALL WINTER POINT MULTIPLIERS WPM <br /> <br />FRAME <br /> <br />WOOD <br />EXT ADJ <br />6.8 5.3 <br />2.5 2.1 <br />2.0 1.8 <br />1.8 1.6 <br />.1.1 1.0 <br />.7 .7 <br /> <br />R.YALUE <br />0-6.9 . <br />7-10.9 <br />11-12.9 <br />13-18.9 <br />19-25.9 <br />26&U <br /> <br />STEEL <br />EXT ADJ <br />9.4 6.7 <br />4.4 3.3 <br />3.3 2.6 <br />3.0 2.4 <br />2.6 2.2 <br />1.4 1.2 <br /> <br /> <br />CONCRETE BLOCK' <br />INT. INSULATION <br />NORMAL WT. <br />EXT ADJ <br />6.0 3.1 <br />3.8 2.3 <br />2.9 1.9 <br />2.3 1.5 <br />1.5 1.1 <br />.8 .7 <br />.5 .5 <br /> <br /> <br />6A.12 DOOR WINTER POINT MULTIPLIERS 6A-13 CEILING WINTER POINT MULTIPLIERS IWPM) <br />DOOR TYPE EXTERIOR ADJACENT UNDER ATTIC SINGLE ASSEMBLY CONCRETE DECK ROOF <br /> R.YALUE WPM R.YALUE WPM CEILING TYPE <br />WOOD 7.6 5.9 19-21.9 1.0 10-10.9 1.8 R.YALUE DROPPED EXPOSED <br /> 22-25.9 .9 11-12.9 1.6 10-13.9 1.2 1.3 <br />INSULATED 5.1 4.0 26-29.9 .7 13-18.9 1.5 14-20.9 .7 .7 <br /> 30-37.9 .6 19-25.9 1.1 21 & Uo .4 .3 <br /> 38 & Uo .4 26-29.9 .6 <br /> ::10 R. lJn A <br />6A.14 FLOOR WINTER POINT MULTIPLIERS IWPM) <br />SLAB.ON-GRADE li;!;i RAISED IIi RAISED WOOJ)2 <br />EDGE INSULATION CONCRETE POST OR PIER STEM WALL wI UNDER ADJACENT <br /> CONSTRUCTION FLOOR INSULATION <br />R.Y AL-lJE WPM R.YALUE WPM }}:; R.YALUE WPM WPM WPM <br />0-2.9 2.5 0-2.9 4.0 0-6.9 7.9 1.8 5.3 <br />3-4.9 -1.7 iii 3-4.9 1.8 7-10.9 2.1 .7 2.1 <br />5-6.9 -2.4 5-6.9 1.1 11-18.9 1.5 .5 1.8 <br />7&UO 7)7 iii 7&Uo A ~n Q 3 10 <br /> <br />WPM) <br /> <br /> 6A.16 DUCT MULTIPLIERS 10M) <br /> RETURN DUCTS RETURN DUCTS <br /> R.Y ALUE IN UNCONDITIONED SPACE IN CONDITIONED SPACE <br /> SUPPLY DUCTS IN 4.2-5.9 1.14 1.10 <br /> 6.0-6.6' 1.10 1.07 <br /> UNCONDITIONED SPACE 6.7 & Uo 1.09 1.06 <br /> SUPPLY DUCTS IN 4.2-5.9 1.10 1.00 <br /> CONDITIONED SPACE' 6.0-6.6 1.07 1.00 <br /> RnlJn 10R 100 <br />6A-17 HEATING SYSTEM MULTIPLIERS IHSMl <br />SYSTEM TYPE HEATING SYSTEM MULTlPLlERSIHSMl <br />Central Heat HSPF 6.40-6.79 6.80.6.89 6.90-7.39 7.40-7.89 7.90-8.39 8.40-8.89 8.9-9.39 9.4-9.89 <br />Pump Units HSM .53 .50 .49 .46 .43 .41 .38 .36 <br /> HSPF 9.90-10.39 10.40-10.89 10.90-11.39 11.40-11.89 11.90-12.39 12.40 & uo <br /> HSM .34 .33 .31 .30 .29 .28 <br />PTHP COP 2.50-2.69 2.70-2.89 2.90-3.09 3.10-3.29 3.30-3.49 3.50-3.69 3.70-3.89 3.90-4.19 <br /> HSM .40 .37 .34 .32 .30 .29 .27 .26 <br />Electric Strio 1.0 <br />Gas & LP Gas 1.0 (See Table 6A-1 8 for Credit Multiolier\ <br /> MINIMUMS: CENTRAL UNITS-AIR SOURCE SPLIT SYSTEM 6.8 HSPF. SINGLE PKG. 6.6 HSPF. WATER SOURCE 3.8 COP. GROUND WATER SOURCE 3.4 COP, PTHP SEE TABLES 6.6 TO 6.8. <br /> <br />6A.15 INFILTRATION WINTER POINT MULTIPLIERS (WPM) <br />INFILTRATION PRACTICE WPM <br />SEE TABLE 6A.21 <br />PRACTICE #1 6.2 <br />PRACTICE #2 4.1 <br /> <br />1 FOR MULTIPLIERS FOR OTHER TYPES OF CONCRETE BLOCK CONSTRUCTION SEE SECTION 2.1 OF APPENDIX C. 2 MULTIPLIERS FOR OTHER TYPES OF RAISED WOOD ASSEMBLIES SEE <br />SECTION 3.1 OF APPENDIX C. 3 DUCTS IN CONDITIONED SPACE NEED TO BE INSULATED ONLY TO THE R-VALUE NECESSARY TO PREVENT CONDENSATION. <br /> <br />.5. <br /> <br />--_.._._.._,~---_. - -----.-- <br />