My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
98-7818
Zephyrhills
>
Building Department
>
Permits
>
1998
>
98-7818
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/4/2009 3:16:26 PM
Creation date
8/25/2006 6:54:28 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
98-7818
Building Department - Name
DONS,AGGIE
Address
38604 PRETTY POND
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />TABLE 6B-1 <br /> <br />MINIMUM REQUIREMENTS <br /> <br />COMPONENTS PACKAGES FOR NEW CONSTRUCTION <br /> A B C 0 E F <br />Max. %01 glass to Roor Area 15% 15% 20% 20% 25% 25% <br />Type Double Clear (DC) Single Tint (ST) Single Tint (ST) Single Tint (ST) Double Tint (DT) Double Tint (DT) <br />Overhang 2' 1'4" 2' 2' 2' 2' <br />Masonry EXTERIOR AND ADJACENT MASONRY WALLS R-5 <br /> COMMON MASONRY WALLS R-3 EACH SIDE_ <br />Wood EXTERIOR, ADJACENT, AND COMMON WOOD FRAME <br />Frame WALLS R-11 <br />CEILINGS CEILINGS UNDER ATTIC R-30. FRAME COMMON CEILINGS R-11_ <br /> (NO SINGLE ASSEMBLY CEILINGS ALLOWED) <br />Slab-On-Grade R-O <br />Raised Wood R-11 (ONLY STEM WALL CONSTRUCTION ALLOWED EXCEPT PACKAGE D) <br />Raised Concrete R-5 <br />DUCTS R-6 R-6 R-6 R-6 R-6 R-6 <br />SPACE COOLING (SEER) 12.0 10,0* 10.0* 12.0 10.0* 10.9 <br />Elect. (HSPF) STRIP 6.8* 6.8* 7.4 6.8* 7.6 <br />Gas/Oil (AFUE) MINIMUM OF .73 (Direct heating) or _78 (Central) <br />Electric EF _90 EF .90 EF .90 EF .90 NOT ALLOWED EF .90 <br />Resistance ** (SEE BELOW) <br />Gas & Oil ** MINIMUM EF OF .54 NATURAl GAS ONLY <br /> (SEE BELOW) <br />Other Any of the following are allowed: dedicated heat pump, <br /> heat recovery unit or solar system. <br /> <br />IT <br />Climate Zones 4 5 6 <br /> <br />~. <br /> <br />TO BE INSTALLED <br /> I I % <br />DC: 0 DT: jg] <br /> , FEET <br />EXT: R= <br />ADJ: R= <br />COM: R= <br />EXT: R= I I <br />ADJ: R= /1 <br />COM: R= <br />UNDER ATTIC: R = 30 <br />COMMOM: R= <br />R= C' <br />R= <br />R= <br />R= (." CONDo 0 <br />SEER = /O,ev <br />COP= _orHSPF=~ <br />AFUE = <br />EF= t '7/ <br />EF= <br />DHP: B EF= - <br />HRU: <br />SOLAR: 0 EF=_ <br /> <br />Single package units minimum SEER=9.7, HSPF = 6.6. <br />Minimum efficiencies for gas and electric hot water systems apply to to 40 gallon water heaters. Refer to Table 6-12 for minimum Code efficiencies for oil water heaters and other sizes. <br /> <br />DESCRIPTION OF BUIlDING COMPONENTS USTED <br />Percent of Glass to Roor Area: This percentage is calculated by dividing the total 01 all glass areas by the total conditioned floor area <br />Overhang: The overhang is the distance the roof or soffit projects out horizontally from the face of the glass. All glass areas shall be under an overl1ang of at least the prescribed length with the following exceptions: 1) glass <br />on the gabled ends of a house and 2) the gtass in the lower stories 01 a multi-story house. <br />Wall, Ceiling and Floor Insulation Values: The R.values indicated represent the minimum acceptable insulation level added to the structural components of the wall, ceiling or floor. The R-value of the structural building <br />materials shall not be included in this calculation. "Common' components are those separating conditioned tenancies in a multilamily building. "Adjacent" components separate conditioned space from unconditioned but <br />enclosed space. 'Exterior' components separate conditioned space from unconditioned and unenclosed space. <br />Roor: Slab-orrgrade floors wilhoul edge insulation are acceptable. Raised wood floors shall have continuous stem walls with insulation placed on the stem wall or under the floor except Package D. <br />Ducts: "CONDO indicates that the ducts must be installed within the conditioned space: that is, the ductwori< shall be located on the conditioned side of the insulation. Ducts in conditioned space are acceptable for any <br />prescriptive package. <br />Space Cooling System: Cooling systems shall have a Seasonal Energy Efficiency Ratio (SEER) for central units or Energy Efficiency Ratio (EER) for room units or PT AC's equal to or greater than the prescribed value. <br />Electric Space Heating Option: Heat pump systems shall be rated with a Healing Seasonal Perfonnance Factor (HSPF) equal to or greater than the prescribed HSPF. Heat pump systems may contain electric strip backups <br />meeting the criteria 01 section 608.1.ABC.3.2.1.2. No electric resistance space heat is allowed lor these packages. <br />Electric ResislanCe Hot Water Option: For packages designated "Not Allowed". an electric resistance hot water system may be installed only in conjunction with one of the "Other Hot Water System Options -. See below. <br />Other Hot WaterSyslem Options: Any dedicated heat pump, heat recovery unit, or solar hot water system may be installed. Solar systems must have an EF of 1.5 or higher. Electric resistance systems having an EF 01 .88 <br />or greater. or natural gas systems with EF .54 or greater may be used in conjunction with these systems. <br /> <br />TABLE 6B-2\ MINIMUM REQUIREMENTS FOR ALL PACKAGES <br />COMPONENTS SECTION REQUIREMENTS CHECK <br />Exterior Joints & Cracks 606.1 To be caulked, gasketed, weather-stripped or otherwise sealed. )( <br />Exterior Windows & Doors 606.1 Max .3 cfmlsq.ft. window area; .5 cfm/sq.ft. door area. )( <br />Sole & Top Plates 606.1 Sole plates and penetrations throuqh top plates of exterior walls must be sealed. I' <br />Recessed Lighting 606.1 Type IC rated with no penetrations (two alternatives allowed). )( <br />Multi-story Houses 606.1 Air barrier on perimeter of floor cavity between floors. bfI <br />Exhaust Fans 606.1 Exhaust fans vented to unconditioned space shall have dampers, except for combustion f <br /> devices with intearal exhaust ductwork. <br />Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) ~ <br /> or cutoff (cas) must be orovided. Extemal or built-in heat trao reauired. <br />Swimming 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a Iplf <br />Pools & 50as oumo timer. Gas soa & 0001 heaters must have minimum thermal efficiencv of 78%. <br />Hot Water Pipes 612.1 Insulation is required for hot water circulating systems (including heat recovery units)_ i ~ <br />Shower Heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. I X. <br />HV AC Duct 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, I <br />Construction, sealed, insulated and installed in accordance with the criteria of Section 610_1. Ducts in attics must be ^ <br />Insulation & Installation insulated to a minimum of R-6. Air handlers shall not be installed in attics unless in mechanical closets. \, <br />HV AC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system_ I /, <br /> <br />-2- <br />
The URL can be used to link to this page
Your browser does not support the video tag.