<br />. ..210-8. Ground-Fault Circuit-Interrupter Protection for Personnel <br /> <br /> <br />FPN: See Section 215-9 for ground-fault circuit-interrupter protection for personnel on feeders. <br /> <br />(a) Dwelling Units. All 1 25-volt, single-phase, 15- and 20-ampere receptacles installed in the locations <br />specified below shall have ground-fault circuit-interrupter protection for personnel. JrE.-.:ar~. <br /> <br />1. Bathrooms. IlC_tar9. <br /> <br />2. Garages, and also accessory buildings that have a floor located at or below grade level not intended as <br />habitable rooms and limited to storage areas, work areas, and areas of similar use. <br /> <br />Exception No.1: Receptacles that are not readily accessible. <br /> <br />Exception No.2: A single receptacle or a duplex receptacle for two appliances located within dedicated <br />space for each appliance that, in normal use, is n~t easily moved from one place to another, and that is cord- <br />and plug-connected in accordance with Section 400-7(a)(6), (a)(7), or (a)(8). :jC.....iiJ1 <br /> <br />Receptacles installed under the exceptions to Section 210-8(a)(2) shall not be considered as meeting the <br />requirements of Section 21 0-52(g). <br /> <br />3. Outdoors. <br /> <br />Exception: Receptacles that are not readily accessible and are supplied by a dedicated branch circuit for <br />electric snow-melting or deicing equipment shall be permitted to be installed in accordance with the applicable <br />provisions of Article 426. ,~~ <br /> <br />4. Crawl spaces. Where the crawl space is at or below grade level. <br /> <br />5. Unfinished basements. For purposes of this section, unfinished basements are defined as portions or areas <br />of the basement not intended as habitable rooms and limited to storage areas, work areas, and the like. <br /> <br />Exception No.1: Receptacles that are not readily accessible. <br /> <br />Exception No.2: A single receptacle or a duplex receptacle for two appliances located within dedicated <br />space for each appliance that, in normal use, is not easily moved from one place to another, and that is cord- <br />and plug-connected in accordance with Section 400-7(a)(6), (a)(7), or (a)(8).rc~ii'1 <br /> <br />Receptacles installed under the exceptions to Section 21 0-8(a)(5) .shall not be considered as meeting the <br />requirements of Section 21 0-52(g). <br /> <br />6. Kitchens. Where the receptacles are installed to serve the countertop surfaces. lI~t':'~i <br /> <br />7 . Wet bar sinks. Where the receptacles are installed to serve the countertop surfaces and are located within <br />6 ft (1.83 m) of the outside edge of the wet bar sink. Receptacle outlets shall not be installed in a face-up <br />position in the work surfaces or countertops. Jc~~ <br /> <br />(b) Other than Dwelling Units. A11125-volt,single-phase, 15- and 20-ampere receptacles installed in the <br />locations specified below shall have ground-fault circuit-interrupter protection for personnel. <br /> <br />1. Bathrooms..'C~~,. <br /> <br />2. Rooftops IlC~a'd <br />