My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
01-0022
Zephyrhills
>
Building Department
>
Permits
>
2001
>
01-0022
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 2:43:49 PM
Creation date
9/29/2006 3:07:02 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
01-0022
Building Department - Name
DARWIN,RAYMOND
Address
ASHVILLE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Exception: Receptacles that are not readily accessible and are supplied from a dedicated branch circuit for <br />electric snow-melting or deicing equipment shall be permitted to be installed in accordance with the applicable <br />provisions of Article 426. <br /> <br />..210-11. Branch Circuits Required <br /> <br />Branch circuits for lighting and for appliances, including motor-operated appliances, shall be provided to supply <br />the loads computed in accordance with Section 220-3. In addition, branch circuits shall be provided for specific <br />loads not covered by Section 220-3 where required elsewhere in this Code and for dwelling unit loads as <br />specified in (c)']iC__t"'il <br /> <br />(a) Number of Branch Circuits. The minimum number of branch circuits shall be determined from the total <br />computed load and the size or rating of the circuits used. In all installations, the number of circuits shall be <br />sufficient to supply the load served. In no case shall the load on any circuit exceed the maximum specified by <br />Section 220-4. <br /> <br />(b) Load Evenly Proportioned Among Branch Circuits. Where the load is computed on a <br />volt-amperes/square foot (0.093 m2) basis, the wiring system up to and including the branch-circuit <br />panelboard(s) shall be provided to serve not less than the calculated load. This load shall be evenly proportioned <br />among multioutlet branch circuits within the panelboard(s). Branch-circuit overcurrent devices and circuits need <br />only be installed to serve the connected load. <br /> <br />(c) Dwelling Units. <br /> <br />(1) Small-Appliance Branch Circuits. In addition to the number of branch circuits required by other parts of <br />this section, two or more 20-ampere small-appliance branch circuits shall be provided for all receptacle outlets <br />specified by Section 210..52(b). <br /> <br />(2) Laundry Branch Circuits. In addition to the number of branch circuits required by other parts of this <br />section, at least one additional 20-ampere branch circuit shall be provided to supply the laundry receptacle <br />outlet(s) required by Section 210-52(f). This circuit shall have no other outlets. <br /> <br />(3) Bathroom Branch Circuits. In addition to the number of branch circuits required by other parts of this <br />section, at least one 20-ampere branch circuit shall be provided to supply the bathroom receptacle outlet(s). <br />Such circuits shall have no other outlets. <br /> <br />Exception: Where the 20-ampere circuit supplies a single bathroom, outlets for other equipment within the <br />same bathroom shall be permitted to be supplied in accordance with Section 210-23(a). <br /> <br />FPN: See Examples DI(a), Dl(b), D2(b), and D4(a) in Appendix D. <br /> <br />..210-52. Dwelling Unit Receptacle Outlets <br /> <br />Receptacle outlets required by this section shall be in addition to any receptacle that is part of a lighting fixture <br />or appliance, located within cabinets or cupboards, or located more than 5~ ft (1.68 m) above the floor. <br /> <br />Permanently installed electric baseboard heaters equipped with factory-installed receptacle outlets or outlets <br />provided as a separate assembly by the manufacturer shall be permitted as the required outlet or outlets for the <br />wall space utilized by such permanently installed heaters. Such receptacle outlets shall not be connected to the <br />heater circuits. <br />
The URL can be used to link to this page
Your browser does not support the video tag.