<br />SECTION 2 <br /> <br />ATTACHED & FREE-STANDING COVERS AND UTILITY SHEDS <br /> <br />Table 2.1.1 Allowable Roof Beam Spans for Carports, Patio Covers, <br />Screen Rooms, and other Open Buildings with Solid Roofs <br />Aluminum Alloy 6063 T -6 <br /> <br />** <br /> <br />Wind Zone = 102 MPH I 110 MPH 120 MPH I 125 MPH I 140 MPH <br />ADDlied Load = 17# / Sa. Ft. I 20# / Sa. Ft. I 23# / Sa, Ft. I 26# / Sa, Ft. I 32# / Sa. Ft. <br />Load Width 2" x 3" x 0.045 Hollow <br />5' 6'-6" S'.11 " C-- S'-7" '/ S'-3" 4'-9" <br />6' S'-11" S'-S" "'5"~1" 4'-9" 4'-4" <br />7' S'-6" S'-1" 4'-9" 4'-S" 3'-11" <br />8' S'-2" 4'-9" 4'-S" 4'-2" 3'-9" <br />9' 4'-10" 4'-S" 4'-2" 3'-11" 3'-6" <br />10' 4'-7" 4'-3" 3'-11" 3'-8" 3'-4" <br />11' 4'-4" 4'-0" 3'-9" 3'-6" 3'-2" <br />12' 4'-2" 3'-10" 3'-7" 3'-S" 3'-1" <br />Load Width 2" x 3" x 0.050 Hollow Tilt <br />5' 7'-4" 6'-9" 6'-4" S'-11" S'-4" <br />6' 6'-8" 6'-2" S'-9" S'-S" 4 '-11" <br />7' 6'-3" S'-9" S'-4" S'-O" 4'-6" <br />8' S'-10" S'-4" 4'-11" 4'-8" 4'-3" <br />9' S'-6" S'-1" 4'-8" 4'-S" 3'-11" <br />10' S'.2" 4'-9" 4'-6" 4'-2" 3'-9" <br />11' 4'-11" 4'-7" 4'-3" 4'-0" 3'-7" <br />12' 4'-9" 4'-4" 4'-1" 3'-10" 3'-5" <br />Load Width 2" x 4" x 0.050 Hollow Tilt <br />5' 9'-0" 8'-4" 7'-9" 7'-4" 6'-7" <br />6' 8'-3" 7'-7" 7'-1" 6'-8" 6'-0" <br />7' 7'-8" 7'-0" 6'-7" 6'-2" 5'-7" <br />8' 7'-2" 6'-7" 6'-2" 5'-9" 5'-2" <br />9' 6'-9" 6'-2" S'.9" S'-S" 4 '-11" <br />10' 6'-5" 5'-11" 5'-6" 5'-2" 4'-8" <br />11' 6'-1" 5'-7" 5'-3" 4'-11" 4'-5" <br />12' S'-10" S'-4" S'-O" 4'-9" 4'-3" <br />Load Width 2" x 4" x 0.036" x 0,100" Self Matina Beam <br />5' 11 '-4" 10'-6" 9'-9" 9'-2" 8'-3" <br />6' 10'-4 " 9'-7" 8'-11" 8'-5" 7'-7" <br />7' 9'-7" 8'-10" 8'-3" 7'-9" 6'-11" <br />8' 8'.11" 8'-3" 7'-9" 7'-3" 6'--7" <br />9' 8'-6" 7'-10" 7'-3" 6'-10" 6'.2" <br />10' 8'-0" 7'-S" 6'-11" 6'-6" 5'-10" <br />11' 7'-8" 7'-1" 6'-7" 6'-2" S'.7" <br />12' 7'-4" 6'-9" 6'-4" 5'-11" 5'-4" <br />Load Width 2" x 5" x 0.050" x 0.100" Self Matina Beam <br />5t 14 '-1" 12'-11" 12'-1" 11 '_So 10'-3" <br />6' 12'-10" 11'-10" 11'-1" 10'-5" 9'-4" <br />7' 11'-11" 10'-11" 10'-3" 9'-7" 8'-8" <br />8' 11'-1" 10'-3" 9'-7" 8'-11" 8'-1" <br />9' 10'-6" 9'-8" 9'-0" 8'-6" 7'-8" <br />10' 9'-11" 9'-2" 8'-7" 8'-1" 7'-3" <br />11' 9'-6" 8'-9" 8'-2" 7'-8" 6'-11" <br />12' 9'-1" 8'-4" 7'-10" 7'-4" 6'-7" <br /> <br />Example: <br />,For 2" x 4" x 0.038" x 0.100" Self-Mating Beam; Beam span between uprights use load width to enter table!. <br />For 12' Roof Panel + 2' Overhang; Load Width = LW = 12' /2 + 2' O,H. = 8' ; Enter table on left at 8' read allowable <br />span under required load: Thus for 100 M.P.H. wind loadllive load or 17 #/Sq. Ft. and Load Width = 8'-0" <br />Maximum Beam Span for 2" x 4" x O,OSO" x 0.100" = I 11'-1" I <br />Spans do not include length of knee brace, Add horizontal length of knee brace to above spans for total beam <br />spans. <br />."Note: <br />For small covers 2" x 2" beams may be used. (see table 3,1.1 for spans) <br /> <br />Lawrence E. Bennett, P.E. <br />CIVIL ENGINEER - DEVELOPMENT CONSUL TANT <br />P.O. BOX 4368, SOUTH DAYTONA, FL 32121 <br />TELEPHONE (904) 767-4774 <br />FAX (904) 767-6556 <br /> <br />SEAL <br /> <br />PAGE <br /> <br />2-20 <br /> <br />@ COPYRIGHT 2000 <br />NOT TO BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN PERMISSION OF LAWRENCE E, BENNETT, P.E, <br />