<br />210.52(F): <br /> <br />210.52(H): <br /> <br />230.70(A)(I): <br /> <br />422.31(B): <br /> <br />Electrical Notes <br />2002 Electrical Code <br />Dave Carr Construction <br /> <br />In dwelling units, at least one receptacle outlet shall be installed for the laundry. <br /> <br />In dwelling units, hallways of3.0 m (10 ft) or more in length shall have at least one <br />receptacle outlet. <br /> <br />As used in this sub-section, the hall length shall be considered the length along the <br />centerline of the hall without passing through a doorway. <br /> <br />The service disconnecting means shall be installed at readily accessible location either <br />outside of a building or structure or inside nearest the point of entrance of the service <br />conductors. <br /> <br />For permanently connected appliances rated over 300 volt-amperes or 118 hp, the branch- <br />circuit switch or circuit breaker shall be permitted to serve as the disconnecting means <br />were the switch or circuit breaker is within sight from the appliance or is capable of being <br />locked in the open position. <br /> <br />11/13/02 <br />1:00 PM <br />