My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
03-2129
Zephyrhills
>
Building Department
>
Permits
>
2003
>
03-2129
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:08:17 PM
Creation date
12/20/2006 9:40:15 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
03-2129
Building Department - Name
CITY OF Z-HILLS
Address
38545 5TH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Ordering Information <br /> <br />Part Number Description I Shin Wt.lb. (kll.) <br />Control Panels <br />EST-FS1004* Conventional Fire Alarm Control Panel-10 Class B lOGs and 4 Class B NACs 30.5 (13.8) <br />(Pairs of IDCs and NACs convertible to single Class A circuits), 120 Vac <br />EST-FS1004-2 Conventional Fire Alarm Control Panel -10 Class B lOGs and 4 Class B NACs 30.5 (13.8) <br />(Pairs of IDCs and NACs convertible to single Class A circuits), 230 Vac. Grey cabinet. <br />EST-FS502* Conventional Fire Alarm Control Panel - 5 Class BlOCs and 2 Class B NACs 18.5 (8.4) <br />(Pairs of lOGs and NACs convertible to single Class A circuits), 120 Vac <br />EST-FS502-2 Conventional Fire Alarm Control Panel - 5 Class BlOCs and 2 Class B NACs 18.5 (8.4) <br />(Pairs of IDCs and NACs convertible to single Class A circuits), 230 Vac. Grey cabinet. <br />EST -FS302* Conventional Fire Alarm Control Panel - 3 Class BlOCs and 2 Class B NACs, 120 Vac 18.0 (8.2) <br />EST -FS302*-2 Conventional Fire Alarm Control Panel - 3 Class BlOCs and 2 Class B NACs, 230 Vac 18.0 (8.2) <br />FSTRIM35* Semi-flush trim ring for FS302 and FS502 1.7 (0.8) <br />FSTRIM 10* Semi-flush trim ring for FS1004 2.2 (1.0) <br />* Insert "G" for Gray cabinet or "R" for Red cabinet. Insert "GP' for French language (grey cabinets, 120 volt models only). <br />Related Items <br />XTRA3A 120 Expander Transformer, 120 Vac - For FS1004* only 4.0 (1.8) <br />XTRA3A230 Expander Transformer, 230 Vac - For FS1004*-2 only 4.0 (1.8) <br />FSCDF35 Electrical terminal shield for 3 & 5 IDC panels. Required for all installations in Canada 1.0 (0.5) <br />FSCDF10 Electrical terminal shield for 10 IDC panels. Required for all installations in Canada 2.0 (0.9) <br />EOL3.6-1.1 Required UL listed End of Une Resistors - One 3.6K Ohm and one 1.1 K Ohm. 0.1 [0.5) <br />One required for each IDC configured as combination waterflow and supervisory. <br />EOL-P1 Required ULC End of Line Resistor Plate - includes one 1.1K, 3.6K and 4.7K Ohm resistor 1.0 (0.5) <br />Off Premises Communications <br />FSDACT Digital CommunicatorlModemlLCD module (Mounts in control panel) 1.0 (0.5) <br />CTM4.7 City Tie Module (Requires 4" square or 2-gang North American electrical box) 1.0 (0.5) <br />RPM Reverse Polarity Module (Requires MFC-A or other listed fire alarm enclosure) 3.0(1.4) <br />Remote Annunciation <br /> Remote System Indicator -Includes LEOs for display of Power, Alarm, Supervisory, Trouble <br />FSRSI and Ground Fault, trouble sounder and silence/lamp test switch. Single gang trim plate 0.3 (0.1) <br />included, multi-gang plates ordered separately. Mounts in a single or multi-gang North <br /> American electrical box. <br /> Remote Zone Indicator -Includes LEOs for five IDCs. <br />FSRZI-A Single gange trim plate included, multi-gang plates ordered separately. 0.3 (0.1) <br /> Mounts in single or multi-gang North American electrical box. <br />FSAT2 Annunciator Trim Plate, 2 gang with FireShield Logo 0.1 (0.05) <br />FSAT3 Annunciator Trim Plate, 3 gang with FireShield Logo 0.1 (0.05) <br />Remote Relay Module <br />FSRRM Remote Relay Module - Five Form C relays. Configurable for IDCs 1-5, or 6-10, or common 0.4 (0.2) <br />system indications. Requires MFC-A or other listed fire alarm enclosure. <br />FSRRM-S11 11" Mounting track. Holds up to 4 FSRRMs. 0.4 to.2) <br />Accessories <br />MFC-A Multi-function Cabinent (fire alarm accessory enclosure) 7.0 (3.2) <br />BC-2 Grey Battery Cabinet (holds two 18 Ah batteries) 12.0 (5.4) <br />BC-2R Red Battery Cabinet (holds two 18 Ah batteries) 12.0 (5.4) <br />Batteries <br />12V4 4Ah Sealed Lead Acid Battery - 12 Vdc (2 required) 5.0 (2.3) <br />12V6 6.5 Ah Sealed Lead Acid Battery - 12 Vdc (2 required) 6.0 (2.7) <br />12V10 10 Ah Sealed Lead Acid Battery - 12 Vdc (2 required) 10.0 (4.5) <br />12V17 17 Ah Sealed Lead Acid Battery - 12 Vdc (2 required) 13.0 (5.9) <br /> <br />,i. <br /> <br />EDWARDS SYSTEMS TECHNOLOGY <br /> <br />It isour intention to keep 1he product information current and accurate. We can not cover specific applications or anticipate all requirements. <br />All specifICations are subject to change wilhout notice. For more Information or questions relative to this Specification Sheet, contact EST. <br /> <br />o!:! 2IIl2 EST <br />Page e of e <br /> <br />Literature She.t #850015-0t 18 <br />Not to be u.ed for Installation purpoa..a. <br />For the most current literature end updat.. visit. .WWW...t.net. <br /> <br />PriIlIadin U.S.A. <br />18.ue 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.