My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
03-2129
Zephyrhills
>
Building Department
>
Permits
>
2003
>
03-2129
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:08:17 PM
Creation date
12/20/2006 9:40:15 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
03-2129
Building Department - Name
CITY OF Z-HILLS
Address
38545 5TH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
27
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Specifications <br /> <br />Control Panels FS1004 FS502 FS302 <br />Initiating Device Circuits - IDCs Class B 10 I 8 6 I 4 2 I 0 5 3 I 1 <br />(Available combinations shown at right) Class A o 1 2 3 4 5 0 1 2 Three Class BlOCs <br />Notification Appliance Circuits - NACs Class B 4 2 0 2 0 <br />(Available combinations shown at right) Class A 0 1 2 0 1 Two Class B NACs <br />Power Supply 3.0 A expandable to 6.0 A 3.0 amps total 2.0 amps total <br />NAC Voltaae Ratina 24 Vfwr <br /> 1.5 amps each,2.5 amps total 1.5 amps each 1.5 amps each <br />Maximum NAC current for NAC 1 + 2 or 3 + 4 <br /> 5.0 A wi optional transformer 2.5 amps total 1.5 amps total <br />AC Input 120 Vac 60 Hz... 1.6 A wi optional transformer 0.8 amps 0.8 amps <br />230 Vac 50/60Hz... 0.8 A wI optional transformer 0.4 amps 0.4 amps <br />Base Panel Current Draw Standby... 145 mA 120 mA 110 mA <br /> Alarm... 250 mA 170 mA 145 mA <br />Panel Battery Charge Capacity (sealed lead acid Up to two 18 Ah batteries Up to 18 Ah, 7Ah max in cabinet * <br />only) <br />Auxiliary Current 0.5 amps max. May be programmed as resetable. <br />Auxiliary Output 19 to 25.7 Vdc <br />IDC Alarm Current 1.5 mA (Consult detector compatibility list pIn 3100468 for maximum detectors per circuit) <br />IDC Circuit Maximum loop resistance: 13 Ohms; Maximum loop capacitance: 0.03 JlF <br />IDC Operating Voltage 16.3 to 25.7 Vdc <br />UL Detector 10 100 <br />Alarm Contact (normally open) <br />Trouble Contact (Form C) 30 Vdc @ 1 A (resistive load) <br />Supervisory Contact (normally open) <br />Operating Environment Temperature: 32 - 1200 F (0 - 490 C); Humidity: 5 - 93% RH, non-condensing <br />Terminals (wire gauge) 18 - 12 AWG 10.75 mm2 - 2.5 mm2) <br />Asynchronous Serial Communications Maximum resistance: 13 Ohms; Maximum capacitance: 0.03 JiF <br />* If larger batteries are required, use the BC-2 battery cabinet. See installation sheet 3100027 for details. <br /> <br />DACT - FSDACT (mounts in panel) <br />Receivers Supports two receivers with two phone numbers each <br />Communications Protocol Contact to (SIA DC-05), 4/2 (SIA DC-02 P3l <br />Programming Front panel controls or PC with appropriate software <br />Telephone line connection Two RJ31X (plug-to-plug) cords supplied with DACT <br />Telephone lines Two or one loop start lines on the public switched telephone network. Pulse or DTMF. <br />Telephone wall connector RJ31X/CA31X equiv. or RJ38X/CA38X equiv. <br />Communications Compliance Communications Canada CS-03; FCC/CFR 47 Parts 15 & 68; NFPA 72; UL 864; ULC S527cM87 <br />Operating Environment Temperature: 32-1200 F {0_490 CJ; Humidity: 93% RH, non-condensing <br />Current requirements Standby: 40 mA; Alarm: 60 mA <br /> <br />Remote Annunciators FSRSI Remote System Indicator FSRZI-A Remote Zone Indicator <br />Maximum per System All panels: 2 10 zone panel: 4 3 or 5 zone panel: 2 <br />Current Requirements Standby: 12 mA Alarm: 48 mA Standby: 8 mA Alarm 35 mA <br />Voltage Range Minimum: 21 Vdc; Maximum: 25 Vdc <br />Maximum Circuit Capacitance 0.03f.1F <br />Maximum Circuit Resistance 13 Ohms <br />Wire Size 18 - 12 AWG (0.75 mm2 - 2.5 mm2J <br />Mounting ANSI/NEMA OS1-1996 1-3 gang electrical box <br />Operating Environment Temperature: 32 - 1200 F (0 - 490 C); Humidity: 93% RH, non-condensing <br /> <br />Remote Relay Module - FSRRM Configured for Zone Mode Configured for Common Mode <br />Maximum per system 10 zone panel: 4; 3 or 5 zone panel: 2 All panels: 2 <br />Current Requirements Standby: 8 mA; Alarm: 65 mA Standby: 30 mA; Alarm: 41 mA <br />Voltage Range Minimum: 18 Vdc; Maximum: 27 Vdc <br />Maximum Circuit Capacitance 0.03 JlF <br />Maximum Circuit Resistance 13 Ohms <br />Wire Size 18 - 12 AWG (0.75 mm2 - 2.5 mm2) <br />Mounting Single FSRRM mounts in plastic track (included) or up to four FSRRMs in an FSRRM-S11 11" track <br /> or..dered separately. FSRRMs should be installed in an MFC-A or other listed fire alarm enclosure. <br />Operating Environment , Temperature: 32 - 1200 F (0 - 490 C); Humidity: 93% RH, non-condensing <br />Dimensions 2-3/4" W x 3-318" H x 1-112" D (65.9 mm W x 85.7 mm H x 38.1 mm D) <br /> <br />I.sue 2 <br /> <br />EDWARDS SYSTEMS TECHNOLOGY <br /> <br />Literature Sheet #85005-0118 <br />Not to be used for installation purposes. <br />Fot" the most current' literature end update. visit www~e.t.n.t'. <br /> <br />P"ge 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.