<br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br /> CHAPTER 4 - Commercial Building Compliance Methods
<br />FORM 400C-01 CENTRAL
<br />Limited and Special Use Buildings Climate Zones 4 5 6
<br />Project Name: Zone:
<br />Address: Building Classification:
<br />City, Zip Code: Building Permit No.:
<br />Builder: Permitting Office:
<br />Owner: Jurisdiction No.:
<br />
<br />LJ hi ~ 'I--
<br />
<br /> UILDING INt-OKMA liON
<br />WAllS ROOF/CEiliNG FLOORS DOORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete CBS) " :;L 'H~ Under Attic 10) ", II 0 Slab-on-Qrade Wood Sinole wall
<br />Wood frame Sinole Assemblv Raised Wood Metal Hie .J.I.(. Double, wall ,Ai :1. It "Lot;
<br />Metal frame In' n ,,(') Other. Raised Concrete Insulated , SinQle, roof
<br />Insulation R-value 15 Insulation R-value Ie; Insulation R-value Other Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br /> AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUlH TYPE
<br />Unitary & Heat Pump Central & Heat Pump Electric
<br /><65,000 Btuth _ SEER r <65,000 Bluth _ HSPF - Resistance ~
<br />~65,OOO BIu/h /J!L EER _IPlV ~65,OOO Btu/h -I- COP J.~ Dedicated Heat Pump
<br />Water cooled _EER _IPlV - Water cooled _COP - Gas
<br />Evaporatively cooled _EER - Evaporatively cooled _COP - Natural 0
<br />PTAC _EER - Electric Resistance _COP - LPG 0
<br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU 0
<br />Gas heat pump _COP - <225,000/300,000 Btuth _ AFUE - Other: 0
<br />Other: - - - ~25,OOO/300,OOO Btuth _E, -
<br />LIGHTING Total Lighting Wattage I J.- 'if 0 · 7;J.. I SIZING CALCULATION I DUCTS R-value Co
<br />Total Conditioned Floor Area /~(J() Watts/sq,ft, Attached 0 Location
<br />
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />Components Section Requirements Check
<br />Operations Manual 102,1 Operations manual will be provided to owner. ")(.
<br />Windows & Doors 406,1 Maximum: ,3 cfm per sq,ft. of window area; Maximum: 1,2 cfm per sq,ft, of door area. >oJ'
<br />Joints/Cracks 406.1 To be caulked, gasketed, weatherstripped or otherwise sealed, ^
<br />Dropped Ceiling Cavity 406,1 Vented: seal and insulate ceiling (no T-bar ceilings), Unvented, no ceiling air barrier: seal and insulate roof and side walls. "'fA
<br />Reheat 407.1 Electric resistance reheat prohibiled. Il4I
<br />Ventilation 409,1 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required, X
<br />HVAC Efficiency 407.1,408.1 Minimum efficiencies - Heating: Tables 4-7,4-8,4-9, Cooling: Tables 4-3, 4-4, 4-5, 4-6, )(
<br />HVAC Controls 407,1 Separate readily accessible manual or automatic thermostat for each system. >-.
<br />HVAC Ducts 410.1 Air duels, fittings. mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated ;.
<br /> and installed in accordance with the criteria of section 410.1.
<br />Balancing 410.1 HVAC distribution system(s) tested and balanced, "-
<br />Piping Insulation 411.1 In accordance with Table 4-11, X
<br />Water Heaters 412,1 Automatic electric storage water heaters $120 gallons and gas & oil fired storage water heaters $75,000 Btuth shall meet
<br /> perfonnance requirements in Table 4-12, Electric >120 gallons: standby loss $.30+27NT. Gas >75,000, Oil >105,000: E. .78, X
<br /> Standby loss $ 1 ,30+114NT, Gas, Oil >155,000: E,.78, Standby loss $ 1,30+95NT,
<br />Swimming Pools 412.1 Spas & heated pools must have covers. Non-commercial pools must have pump timer. Gas spa & pool heaters must M
<br />& Spas have a minimum thermal efficiency of 78%,
<br />Hot Water Pipe 412.1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first 8' of pipe from a storage //11
<br />Insulation tank,
<br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2,5 gpm at 80 psi. Toilets meet 42CFR 6295(k). Public lavatory fixture Nfl
<br /> maximum flow of .5 gpm: or if self-closing valve, .25 gallon circulating, ,5 gallon non-circulating,
<br />Lighting 415,1 Ballasts shall have Power Factors no less than ,90, "
<br />
<br />If required by Florida law, I hereby certify that the system design is in compliance with the Florida Energy Code,
<br />ARCHITECT:
<br />ELECTRICAL SYSTEM DESIGNER:
<br />LIGHTING SYSTEM DESIGNER:
<br />MECHANICAL SYSTEM DESIGNER:
<br />PLUMBING SYSTEM DESIGNER:
<br />
<br />Registration No,
<br />
<br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methodology:
<br />
<br />Detached Buildings <200 sq,ft, 0 Convenience stores <5,000 sq.ft,
<br />Skyboxes/sports stadiums 0 Restaurants <5,000 sq,ft.
<br />Traffic safety control towers 0 Retail stores <5,000 sq.ft.
<br />
<br />o
<br />o
<br />jCl
<br />
<br />Office buildings <5,000 sq.ft.
<br />School buildings <5,000 sq.ft.
<br />Storage buildings <5,000 sq,ft.
<br />
<br />o
<br />o
<br />o
<br />
<br />
<br />~-J-r-d
<br />
<br />Review of plans and specifications covered by this calculation indicates compliance with
<br />the Florida Energy Code. Before construction is completed, this building will be inspected
<br />for compliance in accordance with Sedion 553.908, F.S.
<br />
<br />OWNER AGENT:
<br />
<br />DATE:
<br />
<br />BUILDING OFFICIAL:
<br />DATE:
<br />
|