My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
04-3320
Zephyrhills
>
Building Department
>
Permits
>
2004
>
04-3320
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 3:23:21 PM
Creation date
2/1/2007 11:17:43 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
04-3320
Building Department - Name
E P M C
Address
6943 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />FORM 400C-01 <br />METHOD C <br /> <br />-- <br /> <br />PRESCRIPTIVE REQUIREMENTS LlST* <br /> <br />* All Basic Prescriptive Requirements, designated in the Code by ".1.ABCD" and <br />summarized on the front of this form, must also be met <br /> <br />Detached Commercial Buildings Less than 200 sq.ft. <br /> <br />Table 4C-1 <br /> <br />Glass Area: <br />Overhang: <br /> <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br />Cooling System: <br />Heating System: <br /> <br />No limit. <br />Minimum 1 foot if not under another structure; or <br />No overhang with a glazing Solar Heat Gain Coefficient of 0.48 or less. <br />Minimum insulation level <br />Frame walls - R-11. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level - None. <br />Code minimums as per section 407.1.ABCD.3. <br />Code minimums as per section 408.1.ABCD.3. <br /> <br />Skyboxes or Sports Stadiums <br /> <br />Table 4C-2 <br /> <br />Glass: <br />Overhang: <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br /> <br />Cooling System: <br /> <br />Heating System: <br />Air Distribution: <br /> <br />Lighting: <br /> <br />No limit with glazing Solar Heat Gain Coefficient of 0.48 or less. <br />None required. <br />Minimum insulation level <br />Frame walls - R-11. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level <br />Frame floor- R-19. <br />Concrete floor - None, <br />Minimum equipment efficiency requirements <br />Air cooled -10.0 EER or 10,5 SEER. <br />Water cooled - 11.0 EER. <br />Code minimums as per section 408.1.ABCD,3. <br />A programmable setback shall be installed for in-season use; <br />At least one humidistat control per zone shall be installed for off-season use. <br />EXCEPTION: Installation of a central energy management system. <br />Total connected wattage shall not exceed 1.8 watts per square foot of conditioned space. <br /> <br />Traffic Safety Control Towers <br /> <br />Table 4C-3 <br /> <br />Glass: <br />Overhang: <br /> <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br />Cooling System: <br />Heating System: <br />Lighting: <br /> <br />No limit. <br />Minimum 1 foot if not under another structure; or <br />No overhang with a glazing Solar Heat Gain Coefficient of 0.48 or less. <br />Minimum insulation level <br />Frame walls - R-11. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level - None. <br />Code minimums as per section 407.1.ABCD.3. <br />Code minimums as per section 408.1.ABCD.3. <br />Total connected wattage shall not exceed 2.1 watts per square foot of conditioned space. <br /> <br />General Requirements for Building Packages <5,000 sq.ft. <br /> <br />Table 4C-4 <br /> <br />CUMA TE ZONES 4 5 6 <br /> <br /> <br />I _nO <br /> <br />I u_ <br /> <br />FLOOR: Slab-on-Grade R-O <br />Raised Wood R-19 <br />Raised Concrete R-7 <br />WALL: Masonry R-7 (exterior, adjacent and common) <br />Wood Frame R-11 (exterior, adjacent and common) <br />Metal Frame R-13 (exterior, adjacent and common) <br />ROOF: Insulation above Deck R-19 <br />Insulation in Attic or Dropped Ceiling Cavity R-19 <br />INFIL TRA nON: Code minimums in section 406.1.ABCD.1 <br />DUCTS: Code minimums in section 41 0.1.ABCD.2 <br />DOMESTIC HOT WATER: Code minimums in section 412.1.ABCD.3 <br />LIGHTING CONTROLS: Each space must have the lights divided into at least two "banks" - each one with a manual OnlOff switLtJ; <br />OR Each space must have one occupancy sensor (or other automatic control) to tum the lights on and off. <br /> <br />-2- <br />
The URL can be used to link to this page
Your browser does not support the video tag.