<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br />CHAPTER 4 - Commercial Building Compliance Methods <br /> <br /> <br />CE AL <br />Climate Zones 4 6 <br /> <br /> <br />r-:<- <br /> <br /> BUILDING INFORMATION <br />WALLS ROOF/CEILING FLOORS -DOORS GLASS <br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA <br />Concrete CBS) .N -2'l.&. Under Attic Slab-on-orade leu. Wood Sino Ie wall ''-" 1""3''Z. <br />Wood frame Sinole Assemblv .Il" II JU, Raised Wood Metal .!iil "1..1 Double wall <br />Metal frame ~Q5 4~ Other: Raised Concrete Insulated Sinole roof <br />Insulation R-value Insulation R-value "Z~ Insulation R-value n Other Double, roof <br /> <br /> SYSTEMS INFORMATION <br /> AIR CONDITIONER HEATING SYSTEM HOT WATER <br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUlH TYPE <br />Unitary & Heat Pump 11- SEER 5- Central & Heat Pump Electric <br /><65,000 Btu/h <65,000 Btuth _ HSPF - Resistance 0 <br />2:65,000 Btu/h _EER _IPLV - 2:65,000 Btuth _COP - Dedicated Heat Pump 0 <br />Water cooled _EER _'PLV - Water cooled _COP - Gas <br />Evaporatively cooled _EER - Evaporatively cooled _COP Z &"}'l~ Natural 0 <br />PTAC _EER - Electric Resistance _COP LPG 0 <br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU ~O <br />Gas heat pump _COP - <225,000/300,000 Btuth _ AFUE - Other: N.MJI; 0 <br />Other: ~25,OO0l3oo,Ooo Btu/h E, <br />LIGHTING Total Lighting Wattage '2. q ell:> '2. ~ I SIZING CALCULATION I DUCTS R-value fr, <br /> - : 0 Location Avo.C I...(c <br />Total Conditioned Floor Area 1\ 8~ Watts/sq. ft. Attached <br /> <br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings,) <br />ComDonents Section Reaulrements Check <br />Ooerations Manual 102.1 Operations manual will be orovided to owner. u <br />Windows & Doors 406.1 Maximum: .3 cfm oer so.ft. of window area; Maximum: 1.2 cfm oer so.ft. of door area. I <br />JointslCracks 406.1 To be caulked, oasketed, weatherstriooed or otherwise sealed. " <br />Droooed Ceiling Cavity 406.1 Vented: seal and insulate ceilinotno T-bar ceilings). Unvented, no ceiling air barrier: seal and insulate roof and side walls. " <br />Reheat 407.1 Electric resistance reheat prohibited. ,/ <br />Ventilation . . 409.1 Supplied with readily accessible switch for shut-off and/or volume reduction when ventilation is not required. " <br />HV AC Efficiency 407.1,408.1 Minimum efficiencies - Heating: Tables 4- 7, 4-B, 4-9. Cooling: Tables 4-3, 4-4, 4-5, 4-6. i1' <br />HVAC Controls 407.1 Separate readily accessible manual or automatic thermostat for each system. vi <br />HV AC Ducts 410.1 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated <br /> and installed in accordance with the criteria of section 410.1. aI <br />Balancing 410.1 HVAC distribution system(s) tested and balanced. V <br />Piping Insulation 411.1 In accordance with Table 4-11. <br />Water Heaters 412.1 Automatic electric storage water heaters ~120 gallons and gas & oil fired storage water heaters ~75,OOO Btuth shall meet <br /> performance requirements in Table 4-12. Electric >120 gallons: standby loss ~.30+27Nr. Gas >75,000, Oil >105,000: E, .78, <br /> Standby loss ~ 1.30+114/Vr. Gas, Oil >155,000: E,.7B, Standby loss ~ 1.30+95/Vr. <br />Swimming Pools 412.1 Spas & heated pools must have covers. Non-commercial pools must have pump timer. Gas spa & pool heaters must <br />& Spas have a minimum thermal efficiency of 7B%. <br />Hot Water Pipe 412.1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first 8' of pipe from a storage <br />Insulation tank. <br />Water Fixtures 412.1 Shower head water flow restricted to maximum of 2.5 gpm at BO psi. Toilets meet 42CFR 6295(k). Public lavatory fixture <br /> maximum flow of .5 gpm; or if seif-closing valve...25 gallon circulating, .5 gallon non-circulating. t/ <br />Lighting 415.1 Ballasts shall have Power Factors no less than .90. V <br /> <br />If required by Florida law, I hereby certify ha the syst <br />ARCHITECT: <br />ELECTRICAL SYSTEM DESIGNER: <br />LIGHTING SYSTEM DESIGNER: <br />MECHANICAL SYSTEM DESIGNER: <br />PLUMBING SYSTEM DESIGNER: <br /> <br /> <br /> <br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methodology: <br /> <br />Detached Buildings <200 sq.ft. 0 Convenience stores <5,000 sq. ft. <br />Skyboxes/sports stadiums 0 Restaurants <5,000 sq.ft <br />Traffic safety control towers 0 Retail stores <5,000 sqft. <br /> <br />o <br />o <br /> <br />Office buildings <5,000 sq.ft. <br />School buildings <5,000 sq.ft. <br />Storage buildings <5,000 sq.ft. <br /> <br />o <br />o <br />o <br /> <br /> <br />jf tions covered by the calculation are in compliance with the <br /> <br />PREPARED BY: n .._ ~_ _~_______ DATE11:.1._'1.of_ <br />I hereby cenity that this budding is n c mpliance wilh Ihe Florida Energy Code. <br /> <br />Review 01 plans and specifications covered by this calculation indicates compliance with <br />the Florida Energy CocIe. B e construction completed. this building will be inspected <br />tor compliance In accord a ilh 5 DB. F .S. <br /> <br /> <br />BUILDING OFFICIAL: <br />DATE: <br /> <br />OWNER AGENT: <br /> <br />DATE <br /> <br />FLORIDA BUILDING CODE - BUILDING <br /> <br />13.167 <br />