Laserfiche WebLink
<br />FORM 400C-01 <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />HVAC, GLASS AREA, AND LIGHTING: See Chart below. Select and circle the desired combination of glass-to-wall area percentage (GL AREA %) and <br />lighting level (W/SF) based on the type of HVAC system and efficiency. Report the levels installed on the front of the form. <br /> <br /> Table 4C-5 CONVENIENCE BUILDING < 5,000 SF <br /> MAXIMUM ALLOWABLE GLASS AREA "10 AND ALLOWABLE LIGHTING W/SF <br /> Cooling Equipment Capacity ~5,000 Btuth, Room Units, PTACs II Capacity <65,000 Btu/h <br /> EER: 8.9-9.0 EER: 9.1-10.0 EER: 10.1-11.0 EER: 11.1-UP SEER: 10.0-UP <br /> GL AREA I LIGHTING GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING <br /> % W/SF % W/SF % W/SF % W/P.F % W/SF <br />I 15 I 3.1 I 15 3.1 15 3.5 15 3.9 15 3.9 <br />25 2.8 25 3.3 25 3.4 25 3.5 25 3.5 <br /> 35 2.8 35 3.1 35 3.1 <br />Glazing: 45 2.5 45 2.5 <br />Solar Heat Gain Coefficient <;0.87 And Heat Pump And Heat Pump <br /> COP: > ; 3.0 HSPF: > ; 6.8 <br /> 55 3.9 55 I 3.9 <br /> <br />Table 4C-6 RESTAURANT BUILDING < 5,000 SF <br /> MAXIMUM ALLOWABLE GLASS AREA % AND ALLOWABLE LIGHTING W/SF <br /> Cooling Equipment Capacity ~5,000 Btuth, Room Units, PTACs Capacity <65,000 Btuth <br />EER: 8.9-9.0 EER: 9.1-10.0 EER: 10.1-11.0 EER: 11.1-UP SEER: 10.0-UP <br />GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING <br />% W/SF % W/SF % W/SF % W/SF % W/SF <br />30 1.4 30 1.6 30 1.8 30 2.0 30 2.0 <br />35 1.2 35 1.4 35 1.6 35 1.8 35 1.8 <br /> 40 1.2 40 1.4 40 1.6 40 1.6 <br /> ~ I 45 1.2 45 1.4 <br />Glazing: 45 1.4 <br />Solar Heat Gain Coefficient <;0.77 QI 50 1.0 50 1.2 50 1.2 <br />Double Pane And Heat Pump And Heat Pump <br /> COP: > ; 3.0 HSPF: > ; 6.8 <br /> 65 I 1.8 65 1.8 <br /> <br />Table 4C-7 RETAIL BUILDING < 5,000 SF <br /> MAXIMUM ALLOWABLE GLASS AREA % AND ALLOWABLE LIGHTING W/SF <br /> Cooling Equipment Capacity ~5,000 Btuth, Room Units, PTACs Capacity <65,000 Btuth <br />EER: 8.9-9.0 EER: 9.1-10.0 EER: 10.1-11.0 EER: 11.1-UP SEER: 10.0-UP <br />. GL AREA LIGHTING GL AREA LIGHTING GL AREA LIGHTING Gl AREA LIGHTING GL AREA LIGHTING <br />% W/SF "Ic F % W/SF % W/SF % W/SF <br />35 2.6 735 2.8)- 35 2.9 35 3.0 35 3.0 <br />45 2.4 45 2.6 45 2.7 45 2.8 45 2.8 <br /> 55 2.4 55 2.5 55 2.6 55 2.6 <br />Glazing: 1~~C7 And Heat Pump And Heat Pump <br />Solar Heat Gain Coefficient <;0.87 COP: > ; 3.0 HSPF: > ; 6.8 <br /> 65 3.0 65 3.0 <br /> <br />FLORIDA BUILDING CODE - BUILDING <br /> <br />13.169 <br />