Laserfiche WebLink
<br />PRESCRIPTIVE REQUIREMENTS L1ST* <br />-All Basic Prescriptive Requirements, designated in the Code by ".1.ABCD" and <br />summarized on the front of this form. must also be met. <br /> <br />CLIMATE ZONES 4 5 6 <br /> <br />FORM 400C-01 <br />METHOD C <br />Detached Commercial Buildings Less than 200 sq.ft. <br />. '; .' ., <br /> <br />Glass Area: <br />Overhang: <br /> <br />Walls: <br /> <br />Roofs/C eilings: <br />Floors: ' <br />Cooling System: <br />Heating System: <br /> <br />Tabh!'4C~1 <br /> <br />No limit. <br />Minimum 1 foot if not un~~r.another structure; or <br />No overhang with a glazing Solar Heat Gain Coefficient of 0.48 or less. <br />Minimum insulation level <br />Frame walls - R-11. <br />Masonry walls - R-5, <br />Minimum insulation level- R-19. <br />Minimum insulation level - None. ' , <br />Code minimums as per section 407,1.ABCD.3. <br />Code minimums as per section 408.f.ABCD,3. <br /> <br />Skyboxes or Sports Stadiums <br /> <br />Table 4C-2 <br /> <br />Glass: <br />Overhang: <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br /> <br />Cooling Systl}m: <br /> <br />Heating System: <br />Air Distribution: <br /> <br />Lighting: <br /> <br />No limit with glazing Solar Heat Gain Coefficient of 0.48 or less. <br />None required. <br />Minimum insulation level <br />Frame walls - R-11. <br />Masonry walls :'R-5. <br />Minimum insulation level- R-19. <br />. Minimum insulation level <br />Frame floor- R-19. <br />Concrete floor - None. <br />Minimum equipment efficiency requirements <br />Air cooled - 10,0 EER or 10.5 SEER. <br />Water cooled - 11.0 EER. <br />Code minimums as per section 408.1.ABCD.3. <br />A programmable setback shall be installed for in-season use; <br />At least one humidistat control per zone shall be installed for off-season use. <br />EXCEPTION: Installation of a central energy management system. <br />Total connected wattage shall not exceed 1.8 watts per square foot of conditioned space. <br /> <br />Traffic Safety Con(rol Towers <br /> <br />Glass: <br />Overhang: <br /> <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br />Cooling System: <br />Heating System: <br />Lighting: <br /> <br />Table 4C-3 <br /> <br />No limit. <br />Minimum 1 foot if not under another structure; or <br />No overhang with a glazing Solar Heat Gain Coefficient of 0.48 or less. <br />Minimum insulation level <br />Frame walls - R-11. <br />Masonry walls - R-5. <br />Minimum insulation level - R-19. <br />Minimum insulation level - None, <br />Code minimums as per section 407.1.ABCD,3. <br />Code minimums as per section 408.1.ABCD.3. <br />Total connected wattage shall not exceed 2.1 watts per square foot of conditioned space. <br /> <br />General Requirements for Building Packages <5,000 sq.ft. <br /> <br />~Iabcon-Grade R-O <br />~aised Wood R-19 <br />Raised Concrete R-7 <br />., tvlasonry R-7 (exterior, adjacent and common) <br />Wo6d Frame R-11 (exterior, adjace'nt and conimoni <br />Metal Frame R-13 (exterior, adjacent and common) <br />Insulation above Deck R-19 <br />Insulation in Attic or Dropped Ceiling Cavity R-19 <br />INFILTRATION: Code minimums in section 406.1.ABCD.1 <br />DUCTS: Code minimums in section 410.1.ABCD,2 <br />DOMESTIC HOT WATER: Code minimums in section 412.1,ABCD,3 <br />LIGHTING CONTROLS: Each space must have the lights divided into at least two "banks" - each one with a manual On/Off switch; <br />OR Each space must have one occupancy sensor (or other automatic control) to turn the Iights.on and off. <br /> <br />FLOOR: <br /> <br />WALL: <br /> <br />ROOF: <br /> <br />13.168 <br /> <br />Table 4C-4 <br /> <br />CHECK <br /> <br />~ <br /> <br />~ <br /> <br />-1L- <br />-1L- <br /> <br />~ <br />--L- <br /> <br />FLORIDA BUILDING CODe - BUILDING <br />