<br />FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
<br />CHAPTER 4 - Commercial Building Compliance Methods
<br />
<br />l""IS~. ()()T
<br />
<br />Zone:
<br />Building Classification:
<br />Building Permit No.:
<br />Permitting Office:
<br />Jurisdiction No,:
<br />
<br />
<br />CENTRAL
<br />Climate Zone 6
<br />
<br />t
<br />
<br /> BUILDING INFORMATION
<br />WALLS ROOF/CEILING FLOORS DO.ORS GLASS
<br />TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA TYPE U AREA
<br />Concrete (CBS) L/JI ~frf') Under Attic Slab-on-orade 'Qf.n Wood Sinclle wall .J 71,)"-
<br />Wood frame Sinole Assemblv .[.5 '''f",n Raised Wood Metal t;J -'7.1 Double wall
<br />Metal frame LIX rJ^ Other: Raised Concrete Insulated Sinale roof
<br />Insulation R-value I ~'Z./l 51 Insulation R-value "'7.'" Insulation R-value /") Other Double, roof
<br />
<br /> SYSTEMS INFORMATION
<br /> AIR CONDITIONER HEATING SYSTEM HOT WATER
<br />TYPE EFFICIENCY TONS TYPE EFFICIENCY BTUlH TYPE
<br />Unitary & Heat Pump & SEER ~ Central & Heat Pump Electric
<br /><65,000 Btu/h <65.000 Btu/h _ HSPF - Resistance 0
<br />~65,OOO Btu/h _EER _'PLV - ~65.0oo Btu/h _COP - Dedicated Heat Pump 0
<br />Water cooled _EER _'PLV - Water cooled _COP - Gas
<br />Evaporatively cooled _'EER - Evaporatively cooled _COP 18m Natural 0
<br />PTAC _EER - Electric Resistance _COP LPG 0
<br />Chiller _COP _IPLV - Gas/Oil (circle one) HRU 0
<br />Gas heat pump _COP - <225,000/300,000 Btu/h _AFUE - Other: N~Nt! 0
<br />Other: ~225.000/300,OOO Btu/h E,
<br />LIGHTING Total Lighting Wattage ~B'D /.9 I SIZING CALCULATION I DUCTS R-value r..
<br /> - ''It-/) - 0 Location AtJlJ. C'lr
<br />Total Conditioned Floor Area Watts/sq, It, Attached
<br />
<br /> PRESCRIPTIVE MEASURES (Must be met or exceeded by all buildings.)
<br />Comoonents Section ReQuirements Check
<br />ODe rations Manual 102,1 Operations manual will be provided to owner, ,/
<br />Windows & Doors 406,1 Maximum: ,3 cfm oer so,ft, of window area; Maximum: 1.2 clm oer sq,ft, of door area, {/
<br />Joints/Cracks 406,1 To be caulked, aasketed, weatherSlripped or otherwise sealed, ,J
<br />Dropped Ceiling Cavity 406.1 Vented: seal and insulate ceiling (no T-bar ceilings), Unvented, no ceilino air barrier: seal and insulate roof and side walls, II
<br />Reheat 407,1 Electric resistance reheat prohibited, t/
<br />Ventilation - 409,1 Supplied with readily accessible switch tor shut-off and/or volume reduction when ventilation is not required, i/
<br />HV AC Efficiency 407,1,408,1 Minimum efficiencies - Heating: Tables 4-7, 4-8, 4-9, Cooling: Tables 4-3, 4-4, 4-5. 4-6, r/
<br />HV AC Controls 407,1 Separate readily accessible manual or automatic thermostat lor each system, y
<br />HV AC Ducts 410,1 Air ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated
<br /> and installed in accordance with the criteria of section 410,1. V
<br />Balancing 410,1 HVAC distribution system(s) tested and balanced, v'
<br />Piping Insulation 411.1 In accordance with Table 4-11,
<br />Water Heaters 412..1 Automatic electric storage water heaters :;;120 gallons and gas & oil fired storage water heaters :;;75,000 Btu/h shall meet
<br /> performance requirements in Table 4-12, Electric> 120 gallons: standby loss :;;,30+27 NT. Gas> 75,000, Oil> 105,000: E, .78,
<br /> Standby loss:;; 1.30+114/VT. Gas, Oil >155,000: E,.78, Standby loss oS l,30+951Vr,
<br />Swimming Poois 412,1 Spas & heated pools must have covers, Non-commercial pools must have pump timer. Gas spa & pool heaters must
<br />& Spas have a minimum thermal efficiency of 78%,
<br />Hot Water Pipe 412,1 Piping heat loss is limited to the levels in Table 4-11 for circulating systems and the first 8' of pipe from a storage
<br />Insulation tank,
<br />Water Fixtures 412,1 Shower head water flow restricted to maximum 012,5 gpm at 80 psi. Toilets meet 42CFR 6295(k), Public lavatory fixture
<br /> maximum flow of ,5 gpm; or if self-closing valve,,25 gallon circulating, ,5 gallon non-circulating, t/
<br />Lighting 415,1 Ballasts shall have Power Factors no less than ,90, V
<br />
<br />
<br />Compliance with Chapter 4 was demonstrated by a Prescriptive Measures methodology:
<br />
<br />Detached Buildings <200 sq,ft 0 Convenience stores <5,000 sq,lt
<br />Skyboxes/sports stadiums 0 Restaurants <5,000 sqft,
<br />Trattic safety control towers 0 Retail stores <5,000 sq,lt
<br />
<br />
<br />
<br />o
<br />!i
<br />
<br />Office buildings <5,000 sq,lt,
<br />School buildings <5,000 sq,ft,
<br />Storage buildings <5,000 sq,lt,
<br />
<br />o
<br />o
<br />o
<br />
<br />5 covered by the calculation are in compliance with Ihe
<br />
<br />DATEJl.~.(Jf
<br />
<br />OWNER AGENT:
<br />
<br />DATE
<br />
<br />Review of plans and specifications covered by this calculation indicates compliance with
<br />lhe Florida Energy Code. Belore construction IS mpleted, this building will be inspected
<br />for compliance In accordance wilh ~;iqf}s53 : F.S.
<br />
<br />BUILDING OFFICIAL: _~
<br />
<br />DATE: