Laserfiche WebLink
<br />FORM 400C-Ol <br />METHOD C <br /> <br />Detached Commercial Buildings Les~ t~an 200 sq.ft. <br /> <br />Glass Area: <br />Overhang: <br /> <br />Walls: <br /> <br />Roofs/Geilings: <br />Floors: <br />Cooling System: <br />Heating System: <br /> <br />PRESCRIPTIVE REQUIREMENTS LIST* <br /> <br />'All Basic Prescriptive Requirements, designated in the Code by ".l.ABCD" and <br />summarized on the front of this form, must also be met. <br /> <br />CUMA TE ZONES 4 5 6 <br /> <br />No limit. <br />Minimum 1 foot if not un~~r.another structure; or <br />No overhang with a gla2:ing Solar Heat Gain Coefficient of 0.48 or less, <br />Minimum insulation level <br />Frame walls - R-ll. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level - None. ' . <br />Code minimums as per section 407.1.ABCD.3. <br />Code minimums as per section 408. f.ABCD,3. <br /> <br /> CHECK <br /> , . , <br />Table'4C-l <br /> - <br /> - <br /> , ' - <br /> - <br /> - <br /> . ' - <br /> - <br /> , . <br /> - <br /> - <br />Table 4C-2 <br /> <br />Skyboxes or Sports Stadiums <br /> <br />Glass: <br />Overhang: <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br /> <br />Cooling Sy.stE/m: <br /> <br />Heating System: <br />Air Distribution: <br /> <br />Lighting: <br /> <br />No limit with glazing Solar Heat Gain Coefficient of 0.48 or less. <br />None required. <br />Minimum insulation level <br />Frame walls- R-l1. <br />Masonry walls :R-S. <br />Minimum insulation level- R-19. <br />. Minimum insulation level <br />Frame floor - R-19. <br />Concrete floor - None. <br />Minimum equipment efficiency requirements <br />Air cooled - 10.0 EER or 10.5 SEER. <br />Water cooled - 11.0 EER. <br />Code minimums as per section 408.1,ABCD.3. <br />A programmable setback shall be installed for in-season use; <br />At least one humidistat control per zone shall be installed for off-season use. <br />EXCEPTION: Installation of a central energy management system. <br />Total connected wattage shall not exceed 1.8 watts per square foot of conditioned space. <br /> <br />Traffic Safety Confrol Towers <br /> <br />Glass: <br />Overhang: <br /> <br />Walls: <br /> <br />Roofs/Ceilings: <br />Floors: <br />Cooling System: <br />Heating System: <br />Lighting: <br /> <br />Table 4C-3 <br /> <br />No limit. <br />Minimum 1 foot if not under another structure; or <br />No overhang with a glazing Solar Heat Gain Coefficient of 0.48 or less. <br />Minimum insulation level <br />Frame walls - R-l1. <br />Masonry walls - R-5. <br />Minimum insulation level- R-19. <br />Minimum insulation level - None. <br />Code minimums as per section 407.1.ABCD,3, <br />Code minimums as per section 408.1.ABCD.3. <br />Total connected wattage shall not exceed 2.1 watts per square foot of conditioned space. <br /> <br />General Requirements for Building Packages <5,000 sq.ft. <br /> <br />!:?labCor'l-Grade R-O <br />Raised Wood R-19 <br />RaiS6d Concrete R-7 <br />. , r,..-lasonry R-7 (exterior, adjacent and common) <br />Wood Frame R-ll (exterior, adjacent and common) <br />Metal Frame R.13 (exterior, adjacent and common) <br />Insulation above Deck R-19 <br />Insulation in Attic or Dropped Ceiling Cavity R-l 9 <br />INFILTRATION: Code minimums in section 406,l,ABCD, 1 <br />DUCTS: Code minimums in section 41 0.1.ABCD.2 <br />DOMESTIC HOT WATER: Code minimums in section 412.1,ABCD,3 <br />LIGHTING CONTROLS: Each space must have the lights divided into at I.east two "banks" _ each one with a manual On/Off switch; <br />OR Each space must have one occupancy sensor (or other automatic control) to turn the Iights.on and off. <br /> <br />FLOOR: <br /> <br />WALL: <br /> <br />ROOF: <br /> <br />13.168 <br /> <br />Table 4C-4 <br /> <br />~ <br /> <br />~ <br /> <br />~ <br />~ <br /> <br />;, <br />~ <br /> <br />FLORIDA BUILDING CODE - BUILDING <br />