Laserfiche WebLink
<br />05-30324.05 <br />Page 6 of8 <br /> <br />Test Results: <br /> <br />Paragraph <br /> <br />Title of Test - Test Method <br /> <br />Results <br /> <br />Allowed <br /> <br />Test Specimen #1: H-LC30 48 x 78 (Continued) <br /> <br />2.1.7 <br /> <br />Welded Comer Test <br /> <br />Meets as stated <br /> <br />Meets as stated <br /> <br />2.1.8 <br /> <br />Forced Entry Resistance per AAMA 1302,5-76 <br />Tests A through G No entry . <br /> <br />No entry <br /> <br />Optional Performance <br /> <br />'I <br /> <br />4.3 <br /> <br />Water Resistance per ASTM E 547-00 <br />(with and without screen) <br />WTP =9.0psf No leakage <br /> <br />No leakage <br /> <br />4.4.2 <br /> <br />Uniform Load Structural per ASTM E 330-97 <br />(Measurements reported were taken on the exterior meeting, rail) <br />@ 45.0 psf (positive) 0.04" . 0.179" max. <br />@45.0 psf(negative) 0.06" 0.179" max. <br /> <br />Test Specimen #2: H-LC35 44 x 77 <br /> <br />Optional Performance: <br /> <br />4.4..1 Uniform Load Deflection per ASTM E 330-97 <br />(Measurements rq>orted were taken on, the exterior meeting rail) <br />@35.0psf(positive) 0.44" See Note #2 <br />@ 35.0 psf(negative) 0.46" See Note ~ <br /> <br />. Note #2: The Uniform Load Deflection test is not an A.AMAINWWDA 10111.8.2-97 <br />requirement for. this product designation. The data in this report is for information only. <br /> <br />4.4.2 Uniform Load Structural per ASTM E 330-97 <br />(Measurements reported were t8.ken on the exterior meeting rail) <br />@ 52.5 psf(positive) 0.03" " 0.163" max. <br />@ 52.5 psf(negatjve) 0.03" 0.163" max. . <br />