My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
06-5451
Zephyrhills
>
Building Department
>
Permits
>
2006
>
06-5451
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:22:01 PM
Creation date
5/9/2007 8:55:56 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
06-5451
Building Department - Name
KIMLEY HORN & ASSOC
Address
5344 9TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
33
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />F-60S <br /> <br />DH100ACDC <br />Four-Wire, Low-Profile, <br />Ion & Photo Duct Smoke Detectors <br /> <br />Section: Conventional Initiating Devices <br /> <br />GENERAL <br />The System Sensor DH100ACDC four-wire duct smoke detec- <br />tors are available as either an ionization or a photoelectronic <br />model. This new design allows for simplified cleaning and main- <br />tenance, or a change in application without removing the duct <br />housing. The DH1 OOACDC samples air currents passing through <br />a duct and gives dependable performance for management of <br />fans, blowers, and air-conditioning systems, preventing the <br />spread of toxic smoke and fire gases through the protected area. <br /> <br />/E.WARNING/'f <br /> <br />Duct smoke detectors have specific limitations. <br />DUCT DETECTORS ARE: <br />· NOT a substitute for an open-area smoke detector. <br />· NOT a substitute for early warning detection. <br />· NOT a substitute for a building's regular fire detection <br />system. <br />REFER TO NFPA 72 and 90A for additional duct smoke <br />detector application information. <br /> <br />FEATURES <br /> <br />. Outside mounting tabs. <br />· Telescoping sampling tube (patent pending). <br />. Built-in reset button. <br />· Interconnectability (patent pending) for multi-fan shutdown (up <br />to ten air handlers)." <br />· Cover tamper trouble signal (patent pending). <br />· Easy to clean. <br />· 24 VAC/DC or 120/240 VAC operation. <br />· High-Low voltage barrier. <br />. Ion or photo models available. <br />· Remote test station option. <br />· Remote sounder option. <br />. Air velocity rating from 500 to 4,000 fVmin (152.4 to 1219.2 <br />m/min). <br />· Equipped with two DPDT Form-C relay contacts. <br />· Easy and quick mounting to round or rectangular ducts from <br />1 to 12 feet (2.54 to 30.48 cm) wide. <br />· Textured cover for convenient visual inspection. <br />· UL 268A listed. <br /> <br />SPECIFICATIONS <br /> <br />Dimensions: 14.375" (36.513 cm) wide x 5.500" (13.970 cm) <br />high x 2.750. (6.985 cm) deep. <br />Shipping weight: 3.75Ibs. (1.7 kg). <br />Operating temperature range: 320F to 1310F (OOC to 550C). <br />Operating humidity range: 10% to 93% relative humidity. <br /> <br />November 16, 1999 <br /> <br />@ <br /> <br /><8> <br /> <br />Approved <br /> <br /> <br />California <br />State Fire <br />Marshal <br />3240-1209:155 <br /> <br />S911 <br /> <br />MARYLAND <br />State Fire Marshal <br />RR8281 <br /> <br /> <br />.. <br />-'10 <br />.2 <br />~ <br />.. <br /> <br />Air duct velocity range: 500 to 4,000 ft/min (152.4 to 1219.2 <br />m/min). <br /> <br />ARCHITECTURAL/ENGINEERING <br /> <br />SPECIFICATIONS <br /> <br />The air-duct smoke detector shall be a System Sensor model <br />DH100ACDC Series Duct Smoke Detector. The detector hous- <br />ing shall be UL listed per UL 268A specifically for use in air- <br />handling systems. The detector shall operate at air velocities of <br />500 to 4,000 feet per minute (152.4 to 1219.2 meters per minute). <br />The unit shall be capable of controlling up to ten (10) air-han- <br />dling systems when interconnected with other detectors. The <br />detector shall be capable of providing a trouble signal in the <br />event that the front cover is removed. It shall be capable of <br />local testing via magnetic switch or remote testing using the <br />RTS451 KEY Remote Test Station. The unit shall be reset by <br />local reset button or remote test station. The duct smoke detec- <br />tor housing shall incorporate an airtight smoke chamber in com- <br />pliance with UL 268A, Standard for Smoke Detectors for Duct <br />Applications. The housing shall be capable of mounting to ei- <br />ther rectangular or round ducts without adapter brackets. An <br />integral filter system shall be included to reduce dust and resi- <br />due effects on detector and housing, thereby reducing mainte- <br />nance and servicing. Sampling tubes shall either be telescop- <br />ing or be easily installed by passing through the duct housing <br /> <br />This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. <br />We cannot cover all specific applications or anticipate all requirements. All specifications are SUbject to change without notice. <br />For more information, contact: <br /> <br />'~'.'] I Security Services, Inc. <br /> <br />One Town Center Road, Boca Raton, FL 33431 <br />Phone: (561) 988-3600 FAX; (561) 988-3675 <br /> <br />DA-46765 - Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.