My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
VECTOR SECURITY
Zephyrhills
>
Building Department
>
Permits
>
Product Specification Books
>
VECTOR SECURITY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2008 3:02:09 PM
Creation date
2/13/2008 2:58:26 PM
Metadata
Fields
Template:
Building Department
Company Name
LOWES
Building Department - Doc Type
PSB
Address
7921 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />08130 <br /> <br />Release Module <br /> <br />Specifications <br /> <br />Features <br /> <br />. Two Form C, 5 Amp rated contacts <br /> <br />. Supervised disable switch for system testing <br /> <br />. Easy to install <br /> <br />. Remote control of fire system devices <br /> <br />. Instant or delayed relay activation and restoral <br /> <br />. Compatible with D8112, 08112E & G Series, 09112, <br />D9112B1, D7212, D7212B1, D7412, and D9412 control/ <br />communicators <br /> <br />. Relay closure follows indicating circuit duration <br /> <br />Description <br /> <br />The D8130 Release Module is an accessory for Radionics <br />Rre Alarm Control/Communicators. The 08130 is suitable <br />for release applications commonly found in NFPA 72 Local <br />Fire Alarm Installations. <br /> <br />Two independent Form C dry contacts, each rated at 5 Amps, <br />connect low voltage circuits to magnetic door holders, pilot <br />relays, or contractor units, for release function control. Contact <br />activation on alarm is jumper selectable to be either instant <br />or delayed by ten seconds. If the delay option is selected, a <br />ten second delay also occurs upon restoral. <br /> <br />The control/communicator indicating output activates the <br />contacts of the D8130. A red" ALARM INPUT' LEO is provided <br />on the 08130 module to indicate contact activation. The <br />duration of the contact activation follows the programmed <br />indicating circuit time. If the user silences the alarm output, <br />the 08130 contacts are deactivated. Latching features must <br />be provided for pilot relays or contractor units requiring <br />release control beyond the programmed indicating device <br />time or after manual silencing of the indicating circuits. <br /> <br />Disable Switch <br /> <br />To facilitate fire alarm installation testing, the 08130 Module <br />contains a supervised disable switch that prevents release <br />operation. An amber "OISABLE" LEO is provided on the <br />D8130 to indicate when the switch is in the OISABLE position. <br />The D8130 is connected to any unused protective zone or <br />point of the control/communicator to supervise module <br />disabling. A trouble is indicated on the controVcommunicator <br />when the 08130 switch is in the DISABLE position, and a <br />restoral is sent when the switch is retumed to the NORMAL <br />position. When the contacts are activated with the switch in <br />the NORMAL position, no trouble indications are sent to the <br />control/communicator. <br /> <br /> <br />D8130 Release Module <br /> <br />Release Contact Outputs <br /> <br />A normally open (NO) terminal, a normally closed (NC) <br />terminal, and a common (COM) terminal are provided for <br />each 08130 release contact. Silk screened markings on the <br />edge of the circuit board clearly identify each terminal. In the <br />inactive state of the contact, the NC terminal has continuity <br />with the COM terminal. In the active state of the contact, the <br />NO terminal has continuity with the COM terminal. <br /> <br />Application <br /> <br />The D8130 Release Module is used as a control/ <br />communicator accessory to provide system control functions <br />commonly required in NFP A 72 fire alarm installations. Typical <br />applications are releasing fire doors, emergency exit doors, <br />stairwell doors, elevator recall, smoke exhaust functions, and <br />HV AC control. <br /> <br />Installation <br /> <br />The 08130 Release Module mounts in the control/ <br />communicator enclosure or in a separate approved enclosure. <br />Up to four modules can be installed using the mounting <br />locations provided. A D138 Mounting Bracket is required to <br />mount the D8130 in the D9124. <br /> <br />Install, test and maintain this device according to the <br />Installation Guide, NFPA 72, Local Codes and the Authority <br />Having Jurisdiction. Failure to follow these procedures may <br />result in failure of the device to operate properly. Radionics <br />is not responsible for devices that are improperly installed, <br />tested and maintained. <br /> <br />Wiring to Control/Communicator <br /> <br />Four wires from the D8130 module common (1 COM), <br />altemate alarm output(2 ALT ALRM), +12 VDC (3 AUX PWR), <br />and protective point (4 SWITCH SUPERVISION POINT) <br />terminals connect to the controVcommunicator. These wires <br />connect to the terminal block on the D8130. <br /> <br />~ Radonics. <br />
The URL can be used to link to this page
Your browser does not support the video tag.