Laserfiche WebLink
<br /> <br />Ordering Information <br /> <br />Model Description <br />08125 07212,08112,09112,09412, <br /> 09124 Expansion Module <br />09127Urr Point of Protection Transponder <br /> <br />Electrical Specifications <br /> <br />Operating Nominal12 VOC supplied by <br />Voltaae controVcommunicator <br />Operating 50 mA per 08125 module plus <br />Current 0.5 mA per 09127Urr module <br /> <br />Operational Data <br /> <br />Each 08125 expansion module monitors the 09127 POP ITs <br />over a two-conductor supervised data expansion loop. Off- <br />normal sensor loops (open or shorted), missing, and extra <br />POP ITs are quickly identified by device address and the <br />information relayed to the controVcommunicator. <br /> <br />Each 09127 provides one supervised point of protection. <br />Normally open and/or normally closed contacts may be <br />connected on the same sensor loop. A 33k.Q EOl resistor <br />is provided to be installed at the furthest point on the loop <br />for proper supervision. <br /> <br />wiring Information <br /> <br />(i) ....II1_LOOP <br /><<l._o~- <br />G> . ...111.-n:H ILOCK <br /> <br />1UIIIINAL <br />COIIIlECTOIl8 <br /> <br />. AUX POWEll <br /> <br />- <br /> <br />__A" <br />ANALD_our <br /> <br />-~I <br />e e _il_~l'l <br /> <br />mmmm-=- =:--- <br /> <br />Specifications <br /> <br />The contractor shall furnish and install the 09127 POPIT <br />expansion modules as indicated on the plans. Each <br />POPIT shall provide a supervised sensor loop for initiating <br />devices and identify the device status in off-nonnal <br />conditions. Each POPlT shall be assigned a device <br />address as indicated on the plans and annunciate at the <br />specified locations. The POP ITs shall connect to a 2-wire <br />data expansion loop from a 08125 installed in the controV <br />communicator enclosure. <br /> <br />The 08125 module shall be used for 09124, 09112, <br />09412 or 08112 controVcommunicators and provide <br />supervision for up to 63 or 120 09127 POP ITs on each <br />of up to two modules. <br /> <br />The 08125 module shall be used for 07212 controV <br />communicators and provide supervision for up to 40 <br />09127 POP ITs. <br /> <br />Specified Radionics control/communicators shall be <br />capable of providing device point identification to a remote <br />Radionics 06500 receiver using the Modem II reporting <br />format. All wiring shall be in accordance with the <br />manufacturer's instructions and follow all applicable <br />codes. <br /> <br />Dimensions <br /> <br />08125/08125X: 5" l x 3" W X 3/4" 0 <br /> <br />09127urr: 3 3/16" l x 1 1/2" W x 7/8" 0 <br /> <br />a> <br /> <br />a> <br /> <br />™ The Radionics logo is a registered trademark of Radionics, Salinas, CA, U.S.A. <br />@ 1995.1996 Radionics, Salinas, CA, U.S.A. All rights reserved. <br /> <br />Radionics, 1800 Abbott Street, Salinas, CA, 93901 U.S.A. <br /> <br />~ Radionics.' <br />