<br />Notification Appliance Circuit Supervision Module <br />Specifications <br /> <br />D192C <br /> <br />Features <br /> <br />. Supervises 12 or 24 V DC Notification Appliance <br />Circuits <br /> <br />. Supervised signal silencing switch <br />. Notification appliance circuit rated at 1.8 Amps <br />. Multiple module configurations <br />. Mounts in panel enclosure <br /> <br />Description <br /> <br />The D192C Circuit Supervision Module is an accessory <br />module for use with Radionics Fire Alarm Control <br />Panels (FACPs) and Controll Communicators. The <br />D192C supervises the wiring to remote Notification <br />Appliances in compliance with UL 864 and NFPA 72. <br /> <br />The D192C powers Notification Appliances either from <br />an FACP or from an auxiliary power supply, which <br />allows the use of 12 or 24 V DC Notification Appliances <br />with the appropriate power supply. <br /> <br />The D192C supervises the wiring to Notification <br />Appliances for open circuit, short circuit, or grounded <br />circuit faults. It responds to these conditions by causing <br />a shorted trouble condition on the FACP supervisory <br />zone or point. The panel then provides audible and <br />visual waming at the command center(s). Panel <br />programming may provide Notification Appliance <br />supervision reports to a remote receiver. <br /> <br />In an alarm condition the panel output voltage triggers <br />the D192C to supply power to the Notification <br />Appliances. <br /> <br />The D192C module also filters and stabilizes the output <br />voltage to the Notification Appliances in the event the <br />battery power is interrupted. Several D192C modules <br />can be connected to the same supervisory zone or point <br />of the FACP or control/communicator. <br /> <br />The D192C module has a silence switch to disconnect <br />power to the Notification Appliances during system <br />testing. When this toggle switch is in the Silence (OFF) <br />position, the D192C shorts the supervisory zone or point <br />of the panel, causing a trouble condition. <br /> <br />Notification Appliances used with the D192C module <br />must comply with the following: <br /> <br />. Must be polarized (DC) equipment <br /> <br />. Must match the voltage rating of the alarm power <br />supply <br /> <br /> <br />. Must not exceed the current rating of the alarm <br />power supply <br /> <br />. Combined device current must not exceed 1.8 <br />Amps per D192C module <br /> <br />Application <br />The D192C Module provides a supervised connection <br />point between a Notification Appliance circuit and the <br />FACP. It supervises the Notification Appliance circuit <br />for open, short, and ground condition, any of which the <br />F ACP will report as a trouble condition. <br /> <br />In an alarm situation, the FACP signals the D192C to <br />power the Notification Appliance circuit, either from the <br />F ACP battery or from an auxiliary power supply. <br /> <br />I.. mem:Jer of the <br />30sch Gr~u:J <br /> <br />$ radlonics <br />