My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
VECTOR SECURITY
Zephyrhills
>
Building Department
>
Permits
>
Product Specification Books
>
VECTOR SECURITY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2008 3:02:09 PM
Creation date
2/13/2008 2:58:26 PM
Metadata
Fields
Template:
Building Department
Company Name
LOWES
Building Department - Doc Type
PSB
Address
7921 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Installation <br /> <br />The D192C mounts inside the FACP enclosure. <br />Depending on the configuration of the panel, it <br />may attach using existing mounting holes or with a <br />0137 or 0138 mounting bracket. <br />Using a Class B, Style W, 2-wire circuit, wire the <br />D192C to the FACP according to the Installation <br />Instructions supplied with the module. The D192C <br />requires the following: <br />. 12 V DC auxiliary power <br />. Supervisory zone or point input <br />. Alarm power input of 12 or 24 V DC <br />. Panel common <br />For UL applications, a listed (UTRZ) regulated <br />power supply may be used to power Notification <br />Appliances through the D192C <br /> <br />To comply with NFPA standards: <br /> <br />. The FACP and the power supply must be <br />supervised or installed in the same room not <br />more than 20 feet from the D192C as <br />specified by NFPA <br /> <br />. Wiring between the FACP and the power <br />supply must be in conduit <br /> <br />. Power supply fault conditions must be <br />supervised by a UL-listed relay. <br /> <br />Install according to the Radionics Installation <br />Instructions. Test and maintain equipment according to <br />the Instruction manual, NFPA 72, Local Codes, and the <br />Authority Having Jurisdiction. Failure to follow these <br />instructions may result in a failure to initiate an alarm <br />condition. Radionics is not responsible for improperly <br />installed, tested, or maintained products. <br /> <br />@ 2001 Radionics, a division of Detection Systems, Inc. <br />PO Box 80012, Salinas, CA 93912-0012, USA <br />(800) 538-5807 <br /> <br />Specifications <br /> <br />_III"""'''' ~ . . ,', . '1.""-1$ <br />'~~jo ,~>"' < j-)/"'V:: <br />~ ".~ J"~'*f . ., . ,,'''4 <br /> <br />- <br />Operating Voltage <br /> <br />12 V DC supplied by FACP <br />Auxiliary PONer and/or <br />external power supply <br /> <br />12 V DC supplied by FACP <br />alarm power supply, 12 or 24 <br />V DC supplied by external <br />power supply. Module is rated <br />at 1.8 A @ 12 or 24 V DC <br /> <br />20mA <br /> <br />10mA <br /> <br />1.8A <br /> <br />Alarm Output Voltage <br /> <br />Idle Current <br /> <br />Alarm Current <br /> <br />Maximum Rating <br /> <br />Dimensions <br />(H x W x D) <br /> <br />5 in. x 3 in. x 1.5 in. <br />(12.7 an. x 7.6 em. x 3.8 em.) <br /> <br />Listings and Approvals <br />. Underwriters Laboratories <br />. CSFM <br />. FM <br />. MEA <br /> <br />Ordering Information <br /> <br />. ''k'" 'i;l' ~'~"<'" W~ ' -, ~ ~~:: ~ >-<;;-~~,<,::j:,~~ <br /> ':",,, '~1';l:'. ',', <br />~~~ ,_00;;, ...,,~ I~,'<I. ,c <br />. ~.. ~ , ' <br />. ". ~ - <br />D192C Notification Appliance Circuit Supervision Module <br />D9142F 24 V DC Auxiliary PONer Supply <br />D137 Mounting Bracket <br />D138 Mounting Bracket (for D9124) <br /> <br />~'JnO <br /> <br />CE:UIFICATE N~. A5137 <br />75-07081-000-D 8/01 <br />Specifications D192C <br />L522A Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.