<br />SYMBOL LEGEND <br /> <br />MOUNTING HEIGHT IS FROM FINISHED FLOOR TO CENTERliNE OF DEVICE OR OUTLET. <br />HEIGHT MAY VARY TO COINCIDE I'v1TH BUILDING CONSTRUCTION. <br /> <br />SYMBOL <br /> <br />() CABLE STUB AT CHECKOUT <br /> <br />::@: <br /> <br />DUPLEX RECEPTACLE OUTLET <br /> <br />t <br /> <br />QUAD RECEPTACLE OUTLET <br /> <br />DESCRIPTIQN <br /> <br />:. GROUND F AUL T CURRENT INTERRUPTER TYPE RECEPTACLE <br /> <br />~ <br />& <br />& <br /> <br />TELEPHONE OUTLET. PROYIDE 1 - l' C. (WlTH PULLWIREj TO 6" ABOYE SUSPENDED CEiliNG. REFER TO <br />TELEPHONE WIRING DIAGRAM FOR FURTHER INFORMATION. ' <br /> <br />DATA <br /> <br />o REFER TO ELECTRICAL NOTES <br />o JUNCTlON BOX <br /> <br />GENERAL NOTES (SHEET E-2 ONLY) <br /> <br />MOUNTING <br />HEIGHT <br /> <br />1. ROUTE THE FOLLOWlNG CIRCUITS THROUGH THE ENERGY MANAGEMENT SYSTEM: <br />A. CEILING RECEPTACLES <br />B. WATER HEATERS <br />C. LIGHTED FIXTURE YALANCES <br />2. ELECTRICAL CONTRACTOR MUST FOLLOW TENANT PANEL SCHEDULE. <br />3. ALL EMPTY CONDUITS MUST HAVE PULLWlRES AND BE TAGGED PROPERLY. <br /> <br />4. ELECTRICAL CONTRACTOR SHALL TIE BACK ALL LOOSE WIRING (INCLUDING LOW YOLTAGE) IN AN ORDERLY <br />FASHION, <br />5. AYOID RUNNING LOW VOLTAGE WIRE OVER HIGH YOLTAGE WIRING OR liGHT FIXTURES. <br />6. WIRING SHALL NOT BE EXPOSED AT THE CHECKOUTS. <br />7. PROVIDE CONDUIT FOR ALL WIRING, INCLUDING BUT NOT LIMITED TO CONTROL, FIRE ALARM, POWER AND <br />COMMUNICA TIONS WlRING. COORDINA TE INSTALLATION AND ROUTING REQUIREMENTS WlTH APPROPRIATE <br />INST ALLER(S). <br /> <br />8. UNDERFLooR OR IN SLAB CONDUIT SHALL BE METAL I'v1TH CONCRETE-TIGHT COMPRESSION FITTINGS WHERE <br />PENETRA TING FLOOR SLAB AND SHALL STUB UP VERTICALLY 90 DEGREES. <br />9. PROYIDE SINGLE GANG PLASTER FLANGES FOR ALL TELEPHONE AND DATA <br />OUTLET LOCATIONS AT SPECIFIED HEIGHT. <br /> <br />10. RE -USE ALL UNUSED EXISTING OUTLETS AND CIRCUITS AS APPLICABLE <br />TO THE NEW MERCHANDISE LAYOUT. RELOCATE THE EXISTING AS <br />REQUIRED. <br /> <br />18' AJJ. <br /> <br />18' A.FJ. <br /> <br />18' AJJ. <br /> <br />NOTE: UNLESS OTHERWISE NOTED ALL OUTLETS & J-BOX~S TO BE LOCATED 18" A.F,F. RECEPTICLES TO BE <br />"LEVlTON" #5262-SG1 (IVORY) REVIEW ELECTRICAL NOTES TO VERIFY CONDITIONS PER ELECTRICAL LEGEND. <br /> <br />I' <br />L' <br /> <br /> <br />~ <br />LL <br /> <br />0.. <br />::> <br /> <br />RECEIVING <br />AREA <br />(EXISTING) <br /> <br />0::: <br />W <br />>- <br />W <br />> <br />Z <br />o <br />() <br /> <br /> <br />EMPLOYEe <br />BREAKROOM <br />(EXISTING) <br /> <br />MEN'S <br />RESTROOM . <br />(EXISTING) <br /> <br /> <br />EWlOYEE <br />HALL <br />(EXISTING) <br /> <br />WOME~'S <br />RESTROOM <br />(EXISTiNG) <br /> <br />C.P.U. <br /> <br />0::: <br />W <br />t;:j <br />~ <br /> <br />~ <br /> <br /> <br />. <br /> <br /><:G <br /> <br />ELE <br /> <br /> <br />TRICAL POWER PLAN <br /> <br />SCALE: 1/8'=1'-0' <br />I /'REFERENCED NORTH <br />Orr214f 81 161 <br /> <br />. ~ <br />I <br />32 FEET <br /> <br />2' "2' 0" l' 0' <br />-0 - 4'-0" - 3'-0' 4'-0" 4'-9' <br /> <br />8'-0' <br /> <br />@ <br /> <br />@\ @@ <br />l@ <br />TO EXIST. <br />CIRCUIT <br /> <br />TO EXIST. 'co <br />CIRCUIT -~ <br /> <br />TO EXIST. <br />CIRCUIT <br /> <br /> <br />TO EXIST. <br />CIRCUIT <br /> <br />TO EXIST. <br />- CIRCUIT <br /> <br />@ <br /> <br />RET AL MEA <br />(MODIFIED) <br /> <br /> <br />TO EXIST. <br />CIRCUIT <br /> <br />18'-0' <br /> <br />6'-6" <br /> <br />EJ) <br /> <br />ELECTRICAL LEGEND NOTES (RETAIL AREA): <br /> <br />fR2\ MAKE CONNECTION FROM FRAGRANCE CALL BUTTON TO AMPLIFIER IN CASH ROOM. WlRING FOR CALL <br />~ BUTTON TO BE INSTALLED IN 1/t EMT CONDUIT. CONDUIT TO RUN VERTICAL IN WALL FROM 6" <br />ABOVE CEILING DOWN TO 48' A.FJ. AND HORZ. IN WALL TO BACK OF FRAGRANCE CASE. FROM 6" <br />ABOVE CEILING RUN WIRING DOWN CASH ROOM WALL INTO CASH ROOM AREA OF A.E.!. AMPLIFIER <br />LEA VING s' -0' WIRE LOOP. LOCA TlON OF CALL BUTTON IS TO BE CENTERED ON FRAGRANCE CASE. <br /> <br />@ PROVIDE DEDICATED DUPLEX OUTLET AT 18' AJ.F. FOR BEVERAGE COOLERS AS FOLLOWS: <br /> <br />* BLG-27HD - ONE CORD, NEMA #L14-20P PLUG SUPPLIED, REQUIRES NEMA #l14-20R RECEPTACLE, <br />208-230/60/1 3-POLE 4-WIRE GROONDING. <br /> <br />* BLG-48HD - ONE CORD, NEMA #L'4-20P PLUG SUPPLIED, REQUIRES NEMA #l14-20R RECEPTACLE, <br />208-230/60/1 3-POLE 4-WIRE GROONDING. <br /> <br />* BLG-74HD - ONE CORD, NEMA 1/l14-20P PLUG SUPPLIED, REQUIRES NEMA 1/l14-20R RECEPTACLE, <br />208-230/60/1 3-POLE 4-WIRE GROONDING. <br /> <br />* BMG-27 - ONE CORD, NEMA IS-1SP PLUG SUPPLIED, REQUIRES NEMA #5-15R RECEPTACLE, <br />-POLE 3- WIRE GROUNDING. <br /> <br />* BMG-48 - ONE CORD, NEMA 15-15P PLUG SUPPliED, REQUIRES NEMA #5-15R RECEPTACLE, 115/60/1 <br />2-POLE 3-WIRE GROUNDING. <br /> <br />* BMG-74 - ONE CORD, NEMA jl14-20P PLUG SUPPLIED, REQUIRES NEMA #l14-20R RECEPTACLE, <br />208-230/60/1 3-POLE 4-WIRE GROUNDING. <br /> <br />TGf-23F - ONE CORD, NEMA #5-15P PLUG SUPPLIED, REQUIRES NEMA #5-15R RECEPTACLE, 115/60/1 <br />2-POLE 3- WIRE GROUNDING. <br /> <br />VERIFY EXACT LOCATION AND TYPE OF COOLER/FREEZER I'v1TH TENANT SHEET #F -1 PRIOR TO ROUGH-IN AND <br />INSTALLATION. <br /> <br />fR4\ PROVIDE A STANDARD DUPLEX OUTlET MOUNTED ON RETAIL SIDEWALLS 4' A.FJ. OUTLET TO BE USED FOR <br />\.::.J PLUG WHICH IS PROVIDED WlTH SHELVING KICKPLA TE. COORDINATE EXACT LOCATION I'v1TH FINAL CVS <br />MERCHANDISE PLAN (F-1). RELOCATE EXISTING OUTLETS IF ALREADY PRESENT. <br /> <br />~ PROYIDE DUPLEX OUTLET AT 84' AJJ. (MOUNTED SIDEWAYS) FOR LIGHTED FIXTURE HEADERS. <br />~ RELOCATE EXISTING OUTLETS IF ALREADY PRESENT. <br /> <br />2' - 0' <br /> <br />. . . :r:::' <br /> <br /> <br /> <br />MANAGER'S <br />OFFICE <br />(RELOCA TED) <br /> <br />31'-8' <br /> <br /> <br />TO EXIST. <br />CIRCUIT <br /> <br />SEE DETAIL 2/A-5 <br />FOR MANAGERS <br />OFFICE ELECTRICAL <br />LA YOUT. <br /> <br />TO EXIST. <br />CIRCUIT <br /> <br />. <br /><J:> <br />I <br />Ln <br /> <br />15'-2" <br /> <br />R2 9' <br /> <br />8'-1' <br /> <br />TO EXIST. <br />CIRCUIT <br /> <br />@ <br /> <br />. <br /><D <br />I <br />-"" <br />t'0 <br /> <br />TO EXIST. <br />CIRCUIT <br /> <br />. <br />N <br />I <br />'"" <br /> <br /> <br />TO EXIST. <br />- CIRCUIT , , <br />53 -1 <br /> <br />SEE DETAIL 4 /E-3 <br />FOR HANGING <br />LIGHTED SIGNS. <br /> <br />TO EXIST. <br />CIRCUIT <br /> <br />-"" <br />I <br />Ln <br /> <br />~I <br />36'W1 <br />I <br /> <br />81 <br /> <br />CHECKOUT <br />(NEW) <br /> <br />;.r, <br />I <br /> <br />I <br />I <br />I <br />I <br /> <br /> <br />-" <br />J 5 '[ UASON <br />CAT~ <br />PHOTOlAB I' <br />(NEW) <br /> <br />I <br />I <br /> <br />T <br />C <br />T <br /> <br />o <br />CD <br /> <br />6'-6" <br /> <br />fR12\ PROVIDE FLUSH MOUNTED CEILING DUPLUX RECEPTACLE WlTH WHITE COVERPLA TE FOR NEW <br />\.:..Y LIGHTED HANGING SIGNS. <br /> <br />JR2t.. PROVIDE FLUSH MOUNTED DUPLEX (LE'v1TON #5262-SGW CEILING RECEPTACLE) WITH WHITE <br />'(5' COVERPLA TE (VERIFY I'v1TH PROJECT MANAGER PRIOR TO BIDDING) <br /> <br />@ RELOCATE EXlSTING/ PROYIDE NEW DUPLEX AT 18' A.FJ. FOR NEW FLM/CLM COOLERS. <br /> <br />@ MOUNT DUPLEX AT 60' A.FJ. FOR PRICE CHECKER, ON EXISTING COLUMN OR WALL. <br /> <br />@ <br /> <br />@ <br />@ <br />@ <br />@ <br /> <br /> <br />DES I <br />GRG <br /> <br />PROYIDE PO~R POLE MODEL #25DTP-4 AS MFG'D. BY WlREMOLD W/ALL COMPONENTS FOR A <br />COMPLETE AND STATIONARY INSTALLATION. POWER POLES TO BE FLUSH-MOUNTED TO TOP OF <br />GONDOlA BEHIND ENDCAP. PROVIDE JUNCTlON BOX 6' ABOVE CEILING FOR POWER POLE <br />CONNECTION. <br /> <br /> <br />MOUNT DUPLEX AT 84' AJJ. FOR LIGHTED SHELVES <br /> <br />AOR: ROBERT J. GEHR, A.I.A., NCARB <br />STATE OF FLORIDA SEAL #AR0092168 <br />LARSON DESIGN GROUP, INC. <br />1000 COMMERCE PARK DR. <br />SUI TE 201 <br />WILLlAMSPORT, PA 17701 <br />TEL (570) 323-6603 <br />FAX (570) 323-9902 <br /> <br />MOUNT DUPLEX AT +84' A.FJ OR ON FLOOR FOR LIGHTED SHELVES AT "FACE" AND/OR 'SALON' <br />FIXTURES. <br />MOUNT QUAD ON FLOOR FOR LIGHTED SHELVES AT S.S.C.U.'S. <br /> <br />PROVIDE DUPLEX OUTLET AND DATA LINE. ROUTE ELECTRICAL AND DATA TO NEW CONSULTATION <br />TABLE AS REQUIRED. <br /> <br />fR34\ PROVIDE PO~R POLE MOOEL #NP620-2-12-88 AS MFG'D. BY WlREMOLD W/ALL COMPONENTS <br />\:.:7 FOR A COMPLETE AND STATIONARY INSTALLATION. PROVIDE JJNCTlON BOX 6' ABOVE CEILING <br />FOR POWER POLE CONNECTION. MOUNT BOXES AND ROUTE ELECTRICAL THRU NEW POWER POLE <br />AS REQUIRED. <br /> <br />CONSUL TANT: <br /> <br />B PROVIDE PO~R POLE MODEL #25DTP-4ACT AS MFG'D. BY WIREMOLD W/ALL COMPONENTS FOR A <br />'(J COMPLETE AND STATIONARY INSTALLATION. POWER POLES TO BE FLUSH-MOUNTED TO TOP OF <br />GONDOLA BEHIND ENDCAP. PROYIDE JUNCTION BOX 6' ABOVE CEILING FOR POWER POLE <br />CONNECTION. ROUTE ELECTRICAL AND OATA THRU NEW POWER POLE AS REQUIRED. <br /> <br />Plans, maps, specifications, studies, <br />and reports not containinq a red <br />ink seol imprint accompanied by an <br />original signature by the licensed <br />orofessional may have been <br />fraudulently altered and shall not <br />be considered an original copy. All <br />information should be disregarded <br />unless verified by the professional <br />whose signature appears above. <br />Copyright Protected 2003, <br />Larson Design Group, Inc. <br /> <br /> <br />pharmacy <br />STORE NUMBER: 0651 <br /> <br />37943 EILAND BLVD <br />ZEPHYRHILLS, FL 33541 <br />PROJECT TYPE: <br />00048 ACQUISITION(#0115) <br /> <br />REVISIONS: <br /> <br />STORE SET-UP MANAGER: <br />LAYOUT COORD.: <br />PROJECT ARCHITECT: <br />PLANNING MGR: <br />DRAWING BY: <br /> <br />RJG <br />CS <br /> <br /> <br /> <br />SAB AJM ABB RL W <br /> <br />DRAWING SCALE <br />TITLE: <br /> <br />AS SHOWN <br /> <br />ELECTRICAL <br />POWER PLAN <br /> <br />SHEET NUMBER: <br /> <br />E-2 <br /> <br />OUTLINE : - <br />REVIEW: <br />FINAL: 9/1/04 <br />REVISION <br /> <br />I PERMIT I <br />