My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
BIN A-5 PERMIT 3546
Zephyrhills
>
Building Department
>
Building Plans
>
BIN A-5 PERMIT 3546
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2008 9:30:41 AM
Creation date
2/13/2008 3:08:37 PM
Metadata
Fields
Template:
Building Plans
Street #
37943
Location
EILAND BV
Contractor
FPI CONST
Owner
CVS(PREVIOUSLY ECKERDS)
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />3'-3" EXCEPT <br />W1-IERE NOTED. <br />SEE KEYNOTE ill <br />RETAIL <br />CEILING <br /> <br /> <br /> <br />REYEAL <br /> <br />BOTTOM OF CEILING ~ <br /> <br />PARAWASH FIXTURE; <br />NOTE: <br />POP RIVET CEILING AS <br />NEEDED TO SECUR8 <br />PARAWASH FIXTUR8 IN <br />LOCATION SHOWN. (TYP) <br /> <br />RETAIL <br />SIDE <br /> <br />PHARMACY <br />SIDE <br /> <br />- YALANCE <br /> <br />~ ~~f;L~N lhru TOP OF VALANCE <br /> <br />NOTE: <br /> <br />WITHOUT THE BENEFIT OF A FIELD SURVEY, IT IS <br />ASSUMED THAT THE EXISTING EMERGENCY LIGHTING <br />CURRENTLY IN USE IS FULLY OPERATIONAL AND <br />CONFORMS TO ALL APPLICABLE CODES. ANY <br />BROKEN AND/OR INOPERABLE FIXTURES SHALL BE <br />REPAIRED OR REPLACED ACCORDINGLY. <br /> <br />. <br /> <br /> <br />\, <br />L' <br /> <br />RECEIVING <br />AREA <br />(EXISTING) <br /> <br />5 <br />lL.. <br /> <br />0... <br />~ <br /> <br /> <br />0::: <br />W <br />~ <br />> <br />z <br />o <br />() <br /> <br />EMPLOYEE <br />BREAKROOM <br />(EXISTING) <br /> <br />MEN'S <br />RESTROOM . <br />(EXISTING) <br /> <br />WOMEN'S <br />RESTRoo <br />(EXISTING <br /> <br />INSTALL NEW WAITING AREA <br />HANGING GRAPHIC PANELS <br />geV-25121 <br /> <br />-~ <br /> <br />0::: <br />W <br />[;j <br />:2 <br /> <br />INSTALL NEW "PHARMACY 1" <br />HANGING GRAPHIC PANELS <br />#CV-24490 <br /> <br /><;G <br />ELECTRICAL LIGHTING- <br /> <br />SCALE: 1/8"=1'-0" <br />I ,,'REFERENCED NORTH <br />O~ 81 161 <br /> <br />"32 fEETI ~ <br /> <br />EMPLOYEE <br />HALL <br />(EXISTING) <br /> <br />RETAIL CEILING <br /> <br /> <br />WE <br /> <br />TO EXIST. <br />CIRCUIT <br /> <br />3'-,3" EXCEPT <br />W1-IERE NOTED. <br />SEE KEYNOTE CD <br /> <br /> <br />PARAWASH FIXTURE <br />NOTE: <br />POP RIVET CEILING AS <br />NEEDED TO SECURE <br />PARAWASH ~XTURE IN <br />LOCATION SHOWN. (TYP) <br /> <br />RETAIL <br />SIDE <br /> <br />NEW CHECKOUT/PHOTOIAB <br />GRAPHIC PANELS <br /> <br />u..: . <br />. :z: <br />u... - <br />-.:::;;; <br /> <br />. . <br />o O'l <br />I I <br />ex,'i-- <br /> <br />CHECKOUT / <br />PHOTOLAB <br />SIDE <br /> <br />--~ <br /> <br />FRONT WALL J <br /> <br />SECTION AT CHECKOUT/PHOTOLAB GRAPHIC PANELS <br />SCALE: NONE <br /> <br />INSTALL NEW "STATIONERY' HANGING <br />GRAPHIC PANELS #CV-24495 <br /> <br /> <br />INST ALL NEW "GREETING CARDS" <br />(A.G.) HANGING GRAPHIC PANELS <br />gev- 24503 <br /> <br />INSTALL NEW "PHARMACY 2" <br />HANGING GRAPHIC PANELS <br />gev- 24492 <br /> <br />INSTALL NEW PARAWASH LIGHT <br />FIXTURES AS SHOWN. CENTER ON <br />NEW GRAPHIC PANELS. CONNECT <br />TO EXISTING CIRCUIT. <br /> <br />~ ,/'?...... <br />'? ~.\ <br />~ <br /> <br /> <br /> <br />)~ PATCH AND P.NT E"STlNG <br />II PHARMACY YALANCE AT AREA OF <br />REMOVED CANOPY AS REQUIRED. <br /> <br />~ <br /> <br />PHARMACY <br />(EXISTING) <br /> <br />. . <br /> <br />-I <br /> <br /> <br />tAN <br /> <br /> <br />r <br /> <br /> <br /> <br />LIGHTING FIXTURE SCHEDULE <br />ALL FiXTURES SHALL BE PURCHASED THROUGH: WIEDENBACH-BROWN CO. (888) 230-1569 <br />REFER TO ELECTRICAL SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT NECESSARILY BE REFLECTED IN CATALOG NUMBER AND/OR DESCRIPTION IN THIS SCHEDULE <br /> <br />MARK SYMBOL DESCRIPTION MOUNTING VOLT VA LAMPS BALLASTS <br /> <br />~ 2X4 RECESSED TROFFER RECESSED 120 98 4-F032/835/XP/ECO 1-QT4X32/120LP <br />A ~ METALUX/CVS "A" (SYLVANIA #21763) (SYLVANIA #49537) <br /> <br />RECESSED WALL WASHER 4' 120 70 2-F40W-3500K-BIAXIAL <br />B METALUX/CVS "B" RECESSED (SYLVANIA #20585) <br /> <br /> 0 TRACK FIXTURE SURF ACE, 120 39 1-39W- H.5CMH 1-39E <br />F HALO/L5300-39-SC-PL CEILING <br />PP 0 POWER POLE SURF ACE, 120 <br />WIREMOLD H25DTP-4 CEILING <br />PP-1 0 POWER POLE SURF ACE, 120 <br />WIREM OLD H25DPT - 4ACT CEILING <br />PP-2 0 POWER POLE SURFACE, 120 <br />WIREMOLD HNP620-2-12-8B CEILING <br /> <br />REPLACE ALL DAMAGED AND STAINED CEILING <br />TILES THROUGHOUT STORE AS PER PROJECT <br />MANAGER, <br /> <br />INSTALL NEW AISLE MARKERS AFTER <br />FIXTURING. <br /> <br />CLEAN ALL DIFFUSERS THROUGHOUT STORE <br />AS PER PROJECT MANAGER <br /> <br />ALL HANGING GRAPHIC PANELS ARE TO BE <br />HUNG Wl1l1 THE BOTTOM OF THE GRAPHIC AT <br />8'-0" A.FJ. <br /> <br /> <br />INSTALL NEW "BEAUTY 2" HANGING <br />GRAPHIC PANELS f/CV-24483 <br /> <br /> <br />MANAGER'S <br />OFf1CE <br />(RELOCA TED) <br /> <br />INSTALL NEW "BEAUTY CENTER" <br />HANGING GRAPHIC ARCH f/CY33605 <br /> <br />INSTALL NEW "BEAUTY 1" HANGING <br />GRAPHIC PANELS #CV-24482 <br /> <br /> <br />INSTAll NEW 2 X , LIGHT FIXl1JRE ~ <br />INSIDE AREA OF NEW BEAUTY <br />ARCH GRAPHIC. <br /> <br />INSTALL NEW SPOTLIGHT AT NEW <br />BEAUTY CONSULT A TION CENTER. <br /> <br />PATCH AND PAINT WALLS AT AREAS OF <br />REMOVED GRAPHICS, MIRRORS, PAINTED <br />BANDS, ETC. AS REQUIRED. <br /> <br />INSTALL NEW <br />POWER POLE <br />AS SHOWN <br /> <br />PP-1 <br /> <br />'2 ~,~ <br />PSI <br /> <br /> <br />NO MODIFICATIONS ARE PROPOSED TO THE EXISTING <br />EMERGENCY LIGHTING SYSTEM IN THIS SCOPE OF <br />WORK. IT IS ASSUMED THAT THE EXISTING <br />EMERGENCY LIGHTING SYSTEM PRESENTlY IN USE <br />MEETS ALL CODE REQUIREMENTS, AND IS FULLY <br />OPERA TlONAL. <br /> <br />INSTALL NEW "HEALTH" HANGING <br />GRAPHIC PANELS f/CV-24486 <br /> <br />Ell:> <br />~ <br /> <br /> <br />INSTALL NEW "GROCERY'" <br />HANGING GRAPHIC PANELS <br />geY-24487 <br /> <br />. <br />co <br />I <br />1-0 <br /> <br />, 5' - 2" <br /> <br />RETAL AREA <br />(MODIFIED ) <br /> <br />. <br />N <br />I <br />-co <br /> <br /> <br /> <br />INSTALL NEW "1-HOOR <br />PHOTO. HANGING SIGN. <br />SEE DETAIL 4/E-3. <br /> <br /> <br />. <br />co <br />I <br />-Ll') <br /> <br />9'-2" <br /> <br /> <br />o <br /> <br />INSTALL NEW <br />PO\liER POLES <br />AS SHOWN <br /> <br /> <br />31'-8" <br /> <br />53'-'. <br /> <br /> <br />INSTALL NEW <br />"THANK YOU. <br />HANGING GRAPHIC <br />PANELS ICV-24481 <br /> <br />ENTRANCE <br />(EXISTING) <br /> <br />8 <br /> <br />INSTALL NEW "GREETING <br />CARDS" HANGING SIGN. <br />SEE DETAIL 4/E-3. <br /> <br />INSTALL NEW PARAWASH LIGHT <br />FIXTURES AS SHOWN. CENTER ON <br />NEW GRAPHIC PANELS. CONNECT <br />TO EXISTING CIRCUIT. <br /> <br /> <br />INSTALL NEW "CHECKOUT" HANGING <br />GRAPHIC PANELS #CV-24496 <br /> <br />B <br /> <br />o <br /> <br />CI-ECKOUT <br />(NEW) <br /> <br />INSTALL NEW HANGING TRIANGLE <br />GRAPHIC IICV92378. <br /> <br />PHOTOLAB <br />(NEW) <br /> <br />~-6" <br /> <br /> <br />INSTALL NEW HANGING GRAPHIC <br />PANELS #CV-85110. <br /> <br /> <br />INSTALL NEW <br />POWER POLE <br />AS SHOWN <br /> <br />9'-2" <br /> <br /> <br />INSTALL NEW GRAPHICS PANEL <br />#CV92374. <br /> <br />PP-2 <br /> <br />'1xJ <br />I <br />in <br /> <br /> <br /> <br /> <br />INSTALL NEW GRAPHIC PANEL <br />/jCV92376. <br /> <br />INSTALL NEW "BEVERAGES" <br />HANGING GRAPHIC PANELS <br />#CV-24489 <br /> <br />INSTALL (2) NEW GRAPHIC PANELS <br />/jCY92375. <br /> <br /> <br />DESI <br />GRG <br /> <br />! <br />I <br />I <br /> <br />REMARKS/NOTES <br /> <br />COORDINATE LOCATION W/ <br />INTERIOR GRAPHICS. REF. A-4 <br /> <br /> <br />~~\ <br /> <br /> <br />PROVIDE WITH L973 CANOPY ADAPTER. <br /> <br />\ <br />\ <br />\ <br />AOR: ROBERT J. GEHR, A.I.A., NCARB <br />ST ATE OF FLORIDA SEAL #AR0092168 <br />LARSON DESIGN GROUP, INC. <br />1000 COMMERCE PARK DR. <br />SUITE 201 <br />WILLlAMSPORT, PA 17701 <br />TEL (570) 323-6603 <br />FAX (570) 323-9902 <br /> <br />PROVIDE STATIONARY INSTALLATION. <br /> <br />PROVIDE STA TlONARY INSTALLATION. <br /> <br />PROVIDE STATIONARY INST ALLA TlON. <br /> <br />CONSUL TANT: <br /> <br />LIGHT FIXTURE MARKINGS LEGEND <br /> <br />LIGHT FIXTURES LABELED E= EXISTING FIXTURE TO REMAIN <br />LIGHT FIXTURES LABELED ER= EXISTING FIXTURE RELOCATED <br /> <br />KEYNOTE <br /> <br />ill COORDINATE ALL PARAWASH FIXTURE (TYPE <br />'B') LOCATIONS WITH ARCHITECTURAL PLANS <br />TO ENSURE FIXTURES ARE CENTERED ON <br />WALL GRAPHICS, RELOCATE ANY EXISTING <br />LIGHT FIXTURES, HVAC DIFFUSERS, SPEAKERS, <br />ETC. THAT INTERFERE WITH PROPOSED <br />LOCA TlONS OF NEW LIGHT FIXTURES. MOVE <br />AS MINIMALLY AS POSSIBLE. <br /> <br />Plans, maps, specifications, studies, <br />and reports not containing a red <br />ink seal imprint accompanied by an <br />original signature by the licensed <br />Drofessional may have been <br />lraudulently altered and shall not <br />be considered an original copy. All <br />information should be disregarded <br />unless verified by the professional <br />whose signature appears above. <br />Copyright Protected 2003, <br />Larson Design Group, Inc. <br /> <br />GENERAL NOTES <br /> <br /> <br />1. CUT AND POP RIVET CEILING GRID AS REQUIRED. <br /> <br />pharmacy <br />STORE NUMBER: 0651 <br /> <br />2. ROUTE THE FOLLOWING CIRCUITS THROUGH THE <br />ENERGY MANAGEMENT SYSTEM: A. ALL RETAIL <br />AREA LIGHTING CIRCUITS. B. SIGNS AND EXTERIOR <br />LIGHTING CIRCUITS. C. ALL LIGHTING CIRCUITS IN <br />PHARMACY, D. PHOTOLAB, AND CHECKOUT <br />AREAS. <br /> <br />3. REFER TO ARCHITECTURAL FOR EXACT <br />LIGHTING FIXTURE LOCATIONS, UNLESS <br />OTHERWISE NOTED. <br /> <br />37943 EILAND BLVD <br />ZEPHYRHILLS, FL 33541 <br />PROJECT TYPE: <br />00048 ACQUISITION(#0115) <br /> <br />4. ALL FIXTURES SHALL BE SECURELY <br />SUPPORTED IN ACCORDANCE W1TH NEC <br />ARTICLES 410-15, 410-16. AND 370-13. <br />ALL RECESSED INCANDESCENT FIXTURES <br />SHALL COMPLY WITH NEC ARTICLE <br />410-65C. <br /> <br /> <br /> <br />~ RET~L AND PHARMACY AREA LIGHTING <br />TO BE S\^i1TCHED AT THE MAIN PANEL, <br /> <br />6. ALL RECESSED LIGHT FIXTURES TO BE <br />SUPPORTED INDEPENDENTLY FROM <br />CEILING GRID. (CHAIN SUPPORTS) <br /> <br />7. INSTALL "PARAWASH" FIXTURES AS <br />SHOWN. CUT AND POP RIVET GRID AS <br />NEEDED. (TYPICAL) SEE DETAIL 1 /E-1 <br />ON THIS SHEET. <br /> <br />REVISIONS: <br /> <br />ROOM FINISH SCHEDULE <br /> <br />STORE SET-UP MANAGER: <br />LAYOUT COORD.: <br />PROJECT ARCHITECT: <br />PLANNING MGR: <br /> <br />ROOM NAME <br /> <br />CEIL. HGT, <br /> <br />RJG <br />CS <br />SAB AJM ABB RLW <br /> <br />REMARKS <br />@AS REQUIRED <br />@AS REQUIRED <br />@AS REQUIRED <br /> <br />CEIL <br /> <br />RETAIL AREA <br />CHECKOUT <br />PHOTO lAB <br /> <br />@ <br />@ <br />@ <br /> <br />DRAWING BY: <br /> <br />DRAWING SCALE <br />TITLE: <br /> <br />AS SHOWN <br /> <br />ELECTRICAL <br />LIGHTING PLAN <br /> <br />GENERAL; <br /> <br />-REPLACE ALL BURNED OUT LAMPS AND BALLASTS. <br />-REPLACE ALL STAINED OR DAMAGED CEILING TILES. <br />-CLEAN ALL HYAC DIFFUSERS. <br />-REPAIR OR REPLACE ALL DAMAGED OR INOPERABLE EXISTING EXIT SIGNS AND <br />EMERGENCY LIGHTING, AS REQUIRED. <br />-RELOCATE ALARM SENSORS, CONTROLS, SECURITY CAMERAS, ETC., AS <br />REQUIRED/DIRECTED BY PROJECT MANAGER. <br />-REPAIR OR REPLACE ALL DAMAGED SPRINKLER ESCUTCHEONS, IF APPLICABLE. <br /> <br />SHEET NUMBER: <br /> <br />E-1 <br /> <br />OUTLINE: - <br />REVIEW: <br />FINAL: 9/1/04 <br />REVISION <br /> <br />I PERMITI <br />
The URL can be used to link to this page
Your browser does not support the video tag.