Laserfiche WebLink
<br />I. <br /> <br />PLUMB NG NOTES <br /> <br />i <br />1. GENERAL NOTES ARE APPLICABLE TO ALL PLUMBING IWORKING DRAWINGS. <br />I <br />I <br />2. THE WORK SHALL BE EXECUTED IN STRICT CONFORMITY WITH BASE BUILDING SPECIFICATION AND WITH THE LATEST EDITION OF <br />THE PREVAILING LOCAL PLUMBING AND BUILDING COQES AND ALL LOCAL REGULATIONS THAT MAY APPLY. IN CASE OF CONFLICT <br />BETWEEN THE CONTRACT DOCUMENTS AND A GOVERNING CODE OR ORDINANCE THE MORE STRINGENT STANDARD SHALL APPLY. <br /> <br />3. ALL PLUMBING WORK SHALL BE COORDINATED WITH ALL OTHER TRADES BEFORE PROCEEDING WITH INSTALLATION. <br /> <br />4. NO CHANGES ARE TO BE MADE IN PLUMBING LAYOUT WITHOUT WRITTEN PERMISSION BY THE ARCHITECT. <br /> <br />5. NO PIPING SHALL RUN EXPOSED IN SALES OR FINISHED AREAS. <br /> <br />6. PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND FOR PAYING RELATED FEES. <br /> <br />7. INSTALL BALL VALVES ON ALL BRANCH SUPPLY L1NE~. <br /> <br />8. FOLLOW POI STANDARDS FOR WATER HAMMER ARRESTORS. <br /> <br />9. ALL FIXTURES TO BE SUPPLIED & INSTALLED BY PLUMBING CONTRACTOR, EXCEPT THE PHOTO LAB SINK; <br />OWNER SUPPLIES & PLUMBING CONTRACTOR INSTAllS. <br /> <br />10. SANITARY SEWER PIPING SHOWN IS BASED ON 0.25" PER FOOT FALL FOR ALL PIPiNG. <br />COORDINA TE BUILDING SEWER LOCATION AND INVERT ELEVATION WITH CIVIL DRAWINGS. <br />11. TRAP SEAL PRIMERS ARE TO BE PROVIDED AT NO ADDITIONAL COST TO OWNER IF REQUIRED BY LOCAL BUILDING CODE OFFICIALS. <br /> <br />12. PROVIDE BACKFLOW PREVENTER AS REQUIRED BY LOCAL AUTHORITIES. <br />13. PROVIDE ACCESS DOORS TO ALL INACCESSIBLE VAL~S AND CLEAN-OUTS. MOUNT SHUT-OFF VALVES NO HIGHER THAN 12'-0" AFF. <br /> <br />I" <br />L. <br /> <br /> <br />LUMBING PLAN <br /> <br />SCALE: 1/S.=1'-0. <br />I ,,/'REFERENCED NORTH <br />o~1 <br /> <br />'~2 FEd ~ <br /> <br />-~ <br />8 <br /> <br />16P' <br /> <br /> <br />5 <br />lL.. <br /> <br />Q... <br />:::> <br /> <br />;0 <br />o <br />r <br />r <br />I <br />c <br />-0 <br />o <br />o <br />o <br />;0 <br /> <br />i <br /> <br /> <br />RECBVING <br />AREA <br />(EXISTING) <br /> <br />0:: <br />W <br />GJ <br />> <br />z <br />o <br />o <br /> <br />B <br />, I <br />\ I <br />\ , <br />\../ <br /> <br />. . <br /> <br />(G <br /> <br />EJ) <br /> <br />ITEM <br /> <br />PF-1 <br /> <br />PF-2 <br /> <br />PF-3 <br /> <br />SLOPE <br /> <br />1" PUMPED SANITARY LINE, <br />ABOVE FINISHED CEILING. <br /> <br />1" PUMPED <br />SANITARY LINE, ~ <br />UP TO ABOVE <br />FINISHED CEILING. <br /> <br />1" PUMPED SANITARY <br />LINE, DOWN FROM ABOVE <br />FINISHED CEILING. <br />CONNECT TO EXISTING <br />SANITARY LINE AT OLD <br />SINK LOCATION. <br />~EE FLOOR PLAN) <br /> <br /> <br />SLOPE <br /> <br />INSTALL NEW J J <br />GATE VALVE <br />INSTALL NEW <br />CHECK VALVE <br /> <br />SINK PUMP RISER DETAIL <br />SCALE: NTS <br /> <br />REf AL AREA <br />(MODIFIED ) <br /> <br />DESCRIPTION <br /> <br />MANUF ACTURER <br /> <br />WATER HEATER <br /> <br />EXISTING <br /> <br />SINK PUMP <br /> <br />HRC, INC. <br /> <br />PHOTO-LAB <br />SINK <br /> <br />FURNISHED BY <br />MILLWORK SUPPLIER, <br />INSTALLED BY <br />PLUMBER <br /> <br />PF-3 <br /> <br /> <br />NOTE: <br />VERIFY ALL WORK AND MEASUREMENTS <br />IN FIELD BETWEEN PROJECT MANAGER <br />AND GENERAL CONTRACTOR PRIOR TO <br />ANY WORK BEING DONE. <br /> <br />NOTE!: <br />ALL NEW PLUMBING LINES SHALL BE <br />OR IN FINISHED CHASEWAYS. <br />CONCEALED ABOVE EXISTING CEILING <br /> <br />W <br /> <br />1" <br /> <br />1-1/2" <br /> <br />1-1/2" <br />POLY- <br />PROPEL YNE <br />PIPE <br /> <br />1-1/2" <br /> <br />3/4" C.W, FROM <br />EXISTING SUPPLY <br /> <br />3/4" C.W. LINE (OVERHEAD) <br /> <br />1/2" HW <br /> <br /> <br />8 sE?~ON~STIC WATER RISER DETAIL <br /> <br /> <br />~ <br /> <br /> <br />CHECKOUT <br />(NEW) <br /> <br /> <br />PLUMBING FIXTURE SCHEDULE <br />cw HW REMARKS AND SPECIFICATIONS <br /> <br />v <br /> <br />3/4" 3/4" EXISTING - RELOCATE. <br /> <br />MODEL UMD-70 <br /> <br />PF-3 <br /> <br />1/2" CW <br /> <br />1/2" CW <br /> <br />PF-1 <br /> <br />PROPERLY CAP-OFF <br />OR EXTEND ALL <br />EXISTING PLUMBING <br />AS REQUIRED. <br /> <br />1" PUMPED SANITARY <br />LINE, DOWN FROM ABOVE <br />FINISHED CEILING. <br />CONNECT TO EXISTING <br />SANITARY LINE AT OLD <br />SINK LOCA nON. <br /> <br />MANAGER'S <br />OFFlCE <br />(RELOCA TED) <br /> <br />~ <br /> <br />LEGEND <br /> <br />SANITARY SEWER <br /> <br />DOMESTIC COLD WATER <br /> <br />- - - - DOMESTIC HOT WATER <br /> <br />o <br /> <br />SEE 1/P-1 FOR <br />SINK PUMP DETAIL <br /> <br />1" PUMPED SANITARY LINE, <br />ABOVE FINISHED CEILING. <br /> <br />NOTE!: <br />RE-USE EXISTING SANITARY <br />LINE ABOVE CEILING, IF EXISTING. <br /> <br />1" PUMPED SANITARY LINE, <br />UP TO ABOVE FINISHED CEILING. <br /> <br />1-1 /2" SANITARY VENT, <br />TIE 10 EXISTING VENT LINE. <br /> <br /> <br />~ <br /> <br />1/2" 1/2" <br /> <br />SINK: FIAT MODEL DL-1, DROP-IN SINK WITH ACCESSORY BRASS FAUCET HA1 AND ACCESSORY COYER HA6. PLUMBER TO <br />PROVIDE ALL PIPING, TRAPS, ETC. PROVIDE PVC DISHWASHER DRAIN (OR APPROVED MATERIAL) CONNECTION AND ''y" CLEANOUT <br />AT SINK DRAIN. SILVER SPONGE TO BE CONNECTED TO DISHWASHER DRAIN w/ PVC PLUMBING. <br /> <br />G ELBOW - TURNED DOWN <br />0 ELBOW - TURNED UP <br />I><l GATE VALVE <br />101 BALL VALVE <br />N CHECK VALVE <br />H::>G SHUT -OFF VALVE <br />IN VERTICAL LINE <br />SJl T & P RELIEF VALVE <br /> <br />~~,{1..0 <br />. A.J1d -<\;;.~ <br />I III. ~~f<. . 1) <br />L..{,_\I\ I ~\IUV j \9 <br />j r"' '(L~1 , ~..y\ <br />\ '> (...'IV <br />.. I\> (1P <br />t"~ J <br /> <br /> <br />DES I <br />GRG <br /> <br /> <br />~~~ <br /> <br />\ <br /> <br />\ <br />AOR: ROBERT J. GEHR, A.I.A., NCARB <br />ST ATE OF FLORIDA SEAL #AR0092168 <br />LARSON DESIGN GROUP, INC. <br />1000 COMMERCE PARK DR. <br />SUITE 201 <br />WILLlAMSPORT, PA 17701 <br />TEL (570) 323-6603 <br />FAX (570) 323-9902 <br /> <br />CONSUL TANT: <br /> <br />Plans, maps, specifications, studies, <br />and reports not containing, a red <br />ink seal imprint accompanied by an <br />original signature by the licensed <br />Qrofessional may have been <br />traudulently altered and shall not <br />be considered an original copy. All <br />information should be disregarded <br />unless verified by the professional <br />whose signature appears above. <br />Copyright Protected 2003, <br />Lorson Design Group, Inc. <br /> <br /> <br />I <br /> <br />pharmacy <br />STORE NUMBER: 0651 <br /> <br />37943 EILAND BLVD <br />ZEPHYRHILLS, FL 33541 <br />PROJECT TYPE: <br />00048 ACQUISITION(#0115) <br /> <br /> <br /> <br />REVISIONS: <br /> <br />STORE SET-UP MANAGER: <br />LAYOUT COORD.: <br />PROJECT ARCHITECT: <br />PLANNING MGR: <br />DRAWING BY: <br /> <br />RJG <br />CS <br /> <br />SAB AJM ABB RLW <br /> <br />c) , i~ \l"l <br /> <br />DRAWING SCALE <br />TITLE: <br /> <br />AS SHOWN <br /> <br />PLUMBING PLAN <br /> <br />SHEET NUMBER: <br /> <br />P-1 <br /> <br />OUTLINE: - <br />REVIEW: <br />FINAL: 9/1/04 <br />REViSION <br /> <br />I PERMITI <br />