<br />2 x TOP PLATE
<br />
<br />I
<br />I
<br />""
<br />I
<br />BLOCKS
<br /> r
<br />
<br />PACER
<br />
<br />2 x P.T. PLATE
<br />
<br />.
<br />
<br />
<br />1/4" MIN. SPACE
<br />TRl USP TR 1 W/3 - 8d
<br />COMMON NAILS @ EA
<br />TRUSS OR BLOCKING
<br />(NOTE: (2) 16d TOE NAILS
<br />CAN BE USED IN LIEU OF
<br />TRl STRAP)
<br />2 x STUD @ 24" O.C. MAX.
<br />
<br />SCALE: N.T.S.
<br />
<br />TYPICAL INTERIOR NON-BEARING
<br />
<br />REV. USP 07-28-04 TH
<br />
<br />
<br />NOTE:
<br />PLATE LENGTHS MUST BE
<br />AT LEAST 8'-0" LONG. TYPICAL
<br />
<br />-BOTTOM SPLICE
<br />OVER STUD
<br />
<br />"T"
<br />
<br />CORNER
<br />
<br />TYPICAL "T" AND CORNER DETAIL
<br />
<br />
<br />SCALE: N.T.S.
<br />
<br />
<br />
<br />
<br />
<br />
<br />REV. 9/03
<br />
<br />P.T. PLATE
<br />SCALE: N.T.S.
<br />
<br />2 - S.P.F. CONST. GRADE TOP PLATE
<br />SPLICE MIN 48" APART
<br />o NAIL AT BASE 2 ROWS 4" OIC STAGGER
<br />W/8d COMMON NAIL
<br />@ NAIL AT TOP PLATE 2 ROWS 4" OIC STAGGER
<br />W/8d COMMON NAIL
<br />@ NAIL OPENING PERIMETER @ 3" O.C. W/8d
<br />COMMON NAIL
<br />@ NAIL INT. AT 6" O.C. W/8d COMMON NAIL
<br />@ STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C.
<br />w/8d COMMON NAIL
<br />CD NO SPLICE @ HEADER - NAIL SHEATHING TO
<br />HEADER W/frd COMMON NAIL@ 4" ole
<br />2x4 P.T. BASE PLATE
<br />
<br />
<br />-11- If -II
<br />II II II
<br />II II II
<br />II II II
<br />
<br />II
<br />II
<br />II II II
<br />11_ lL JI_
<br />FLOOR SY ~MII
<br />x8 P .T. SIEL PLAT
<br />2 STORY ONLY)
<br />
<br />WALL SHEATHING INSTALL. & NAILING SCHED.
<br />NO SCALE REV. 5/12/04
<br />
<br />
<br />1 1
<br />:V: TRUSS/JOIST/RAFTER
<br />1 1
<br />~--- -------,--,
<br />I I (1)USPRT16T
<br />: w/7-10d x 1 1/2" TO BOTH
<br />__ L _ TRUSS AND DBL. TOP PLATE
<br />2 - 2x4 TOP PLATE
<br />CONST. GRADE SPF
<br />USP SPT 24 w/6-10d
<br />TO STUD & TO TOP PLATE
<br />
<br />2x4 SPF STUDS @ 16" O.C.
<br />
<br />
<br />A
<br />
<br />USP SPT 22 w/ 4 -10d TO
<br />STUD & 4-10d TO BASE PLATE
<br />1/2" x 8" A307 A.B. OR 5/8"x 7"
<br />WEDGE ANCH. w/2" WASHER 6"
<br />FROM ENDS & JOINTS & @32" O.C.
<br />MIN'lw/#3 PT PLATE
<br />
<br />
<br />I
<br />,- - - - - - - - ""-
<br />,
<br />,
<br />"
<br />
<br />I
<br />r--------.,
<br />/
<br />/
<br />/
<br />
<br />: 1
<br />-.1
<br />1
<br />1
<br />
<br />SEE FND PLAN
<br />FOR FOOTING
<br />SIZE AND REINF.
<br />
<br />INTERIOR BEARING
<br />w/UPLlFT
<br />
<br />
<br />NO SCALE REV. 09/13/04 TH
<br />THIS DETAIL REQUIRED ONLY WHEN & WHERE
<br />SPECIFICALLY INDICATED BY THIS SYMBOL
<br />UPLIFT VALUES - (DOUBLE SIDE CONNECTORS-DOUBLES VALUE BELOW)
<br />1 (EACH CONNECTOR) EACH STUD - 462 PLF
<br />
<br />L
<br />
<br />2- ROWS OF
<br />10d @ 4" O/C
<br />MAX.
<br />10d @ 8" O/C
<br />
<br />TOP PLATE SPLICE DETAIL
<br />SCALE: N.T.S. 5/6/04
<br />
<br />PRE ENGINEERED WD TRUSSES @ 24" O.C.
<br />INSULATION BAFFLE
<br />BATT OR BLOWN INSULATION MIN. R-19
<br />TRUSS ANCHOR (SEE PLAN)
<br />FIBERGLASS SHINGLE
<br />ROOFING FELT
<br />-APA RATED STRUCTURAL SHEATHING
<br />MIN 7/16" FASTENED TO TRUSSES W/
<br />8d COMMON WIRE NAILS @ 4" O/C
<br />_ _B'pUND_ARIES.~QjC EDGES & 8" O/C FIELD
<br />~ METAL DRIP EDGE
<br />2" X SUBFASCIA
<br />CONT. VENTED ALUM SOFFIT
<br />8" X 8" X 16" K.O. LINTEL BLOCK
<br />W/l #5 DIA. REBAR &
<br />FILLED SOLID W/GROUT
<br />PRECAST "U" LINTEL
<br />(SEE S/2A FOR LINTEL
<br />SIZE & REINFORCEMENT)
<br />FILL CELL -1 #5 DIA. REBAR W/ GROUT
<br />@ ALL LOCATIONS SHOWN ON
<br />FOUNDATION & FLOOR PLANS
<br />ALUM FRAMED WINDOW W/ SCREEN
<br />PRECAST CONC SILL
<br />8" X 8" X 16" CONC. BLOCK
<br />DECORATIVE FINISH
<br />FTG. DOWEL #5 DIA. REBAR
<br />18" IN CONC. -25" EXTEND (ACI 530)
<br />ABOVE SLAB. ALL LOCATIONS
<br />SHOWN ON FOUNDATION PLAN
<br />
<br />
<br />1
<br />1/2" CD DRYWALL :
<br />3/4" P.T. NAILER
<br />1/2" DRYWALL
<br />CURTAIN NAILER
<br />1 X 4 P.T. @ WINDOWS
<br />1 X 8 P.T. @ S.G.D.
<br />
<br />MARBLE STOOL
<br />1 X 2 P.T FURRING
<br />R-3 FOIL INSUL ON EXT
<br />BLOCK WALLS
<br />1 X 4 P.T. BASE NAILER
<br />WOOD BASE
<br />3 1/2" CONC SLAB ~
<br />6 X 6 10/10 W.W.M.
<br />6 MIL VISQUEEN
<br />
<br />TREATED-
<br />CLEAN FILL
<br />
<br />SEE FND. PLAN FOR
<br />FOOTING SIZE AND
<br />REINF.
<br />
<br />TYPICAL WALL SECTION
<br />CONCRETE BLOCK REV. (STEM) 1/18/05 TH
<br />
<br />I I
<br />1 1 ,
<br />:: ~ TRUSS/RAFTER
<br />
<br />~" ,
<br />: 1 /,' /,'" USP H1W20 W/24-10d x 1 1/2"
<br />1 ... ,// TO BOTH TRUSS
<br />__L_ ~ AND DBL. TOP PLATE/STUD
<br />--------- 2-2x4TOPPLATE
<br />CONST. GRADE SPF
<br />
<br />USP SPT24 W/6-10d TO
<br />STUD & TO TOP PLATE
<br />2x4 SPF STUDS @ 16" O.C,
<br />
<br />
<br />A
<br />
<br />USP SPT22 W/4-10d TO
<br />STUD & 4-10d TO BASE PLATE
<br />#3 PT PLATE WI 1/2" x 8" A307 A.B. OR 1/2" dia. x 6"
<br />TITEN H.D. @ 6" FROM CORNERS & JOINTS & @ 32" O.C.
<br />
<br /> 2"x4" P.T. PLATE
<br /> 1/2" x 8" ANCHOR
<br /> BOLT W/ 2" x 1/8" FLAT 12
<br /> WASHER (TYP)
<br />@ @ @
<br />J 32" ~ 32" J
<br />
<br />
<br />SEE F~OOR PLAN
<br />
<br />SEE FND PLAN FOR
<br />FOOTING SIZE AND
<br />REINF.
<br />
<br />
<br />
<br />SCALE: N.T.S.
<br />
<br />
<br />TRUSSES
<br />
<br />USP RT 16
<br />@ 16" O.C.
<br />
<br />-----
<br />-----
<br />
<br />
<br />2 - 2x4 CONST. GR. SP
<br />TOP PLATE. SPLICE
<br />24" APART MIN.
<br />
<br /> UPLIFT CONNECTION CROSS-REFERENCE
<br />USP STRUCTURAL CONNECTORS SIMPSON STRONG-TIE
<br /> UPLIFT LATERAL FASTENERS CONNECTOR UPLIFT LATERAL FASTENERS
<br />CONNECTOR r'~'~'~'yl CAPACITY CAPACITY ~.~.~.~,
<br /> ;11 Y
<br /> MASONRY APPLICATIONS MASONRY APPLICATIONS
<br />HTA16 1500 590 13-10d x 11/2" META16 1450 335 7-10d x 11/2"
<br />HTA20 1500 590 13-10d x 11/2" META20 1450 335 7-10d x 11/2"
<br />HTT16 4290* - 18-16d HTT16 4175* - 18-16d
<br />HTT22 5370* - 32-16d HTT22 5260* - 32-16d Sinkers
<br />LUGT2 1850 16-10d & 5-1&4"X3" LGT2 2150 16-16d Sinkers & 7-
<br />- Wed~e bol s - 1/4"x2 1/4" Titen
<br />L TS19 1390* - 8-10d L TT19 1350* - 8-16d Sinkers
<br />L TTI31 2650* - 18-10d x 11/2" L TTI31 2310* - 18-10d x 11/2"
<br /> FRAME APPLICATIONS FRAME APPLICATIONS
<br />RT7 585 170 10-8d x 11 2" H2.5 415 150 10-8d x 11/2"
<br />RT16 1030 645 16-8d x 1 1 2" Hl0 990 525 16-8d x 11/2"
<br />RT16-2 1030 390 16-8d x 1 1 2" Hl0-2 760 395 12-10d
<br />SPT22 715 260 8-10d SPl 585 - 10-10d
<br />SPT24 1075 260 12-10d SP2 1065 - 12-10d
<br />SPT4 885 - 6-10d x 11/2" SP4 885 - 6-10d x 11/2"
<br />SPTH4 1730 - 12-10d x 11/2" SPH4 1360 - 12-10d x 11/2"
<br />MUGT15 3965 - 22-10d MGT 3965 - 22-10d
<br />LUGT2 2260 - 32-10d LGT2 2050 - 30-16d Sinkers
<br />HTW20 1530 95 20-10d HTS20 1450 - 20-10d
<br />MSTA18 1275 - 14-10d LSTA18 1165 - 14-10d
<br />MSTA24 1305 - 18-10d LSTA24 1235 - 18-10d
<br />MSTA30 1635 - 22-10d LSTA30 1640 - 22-10d
<br />MSTA36 1635 - 22-10d LSTA36 1640 - 24-10d
<br /> HUNG APPLICATIONS HUNG APPLICATIONS
<br />HUS26 1925 - 20-16d HUS26 1550 - 20-16d
<br />THDH26-2 2605 - 30-16d HGUS26-2 2325 - 28-16d
<br />HUS28 2570 - 30-16d HUS28 2000 - 30-16d
<br />THDH210-2 3970 - 58-16d HGUS28-2 3220 - 48-16d
<br />
<br />* CAPACITY IS BASED ON CONCRETE EMBEDMENT, REFER TO MANUFACTURER FOR GROUT FILLED
<br />CMU
<br />NOTES :
<br />1) CONNECTOR CAPACITIES ARE FOR SYP, REFER TO MANUFACTURERS FOR ADDITIONAL
<br />INFORMATION
<br />2) DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH
<br />COULD FORCE THE PLATE OFF THE TRUSS.
<br />
<br />3-12d EA. END
<br />OF BLOCKING
<br />
<br />- - --
<br />- - --
<br />
<br />STRUCTURAL SHEATHING
<br />(MIN. 7/16"). NAIL 3" O.C.
<br />EDGES STAGGERED, & 6" O.C.
<br />INTERIOR.
<br />
<br />#3 PT PLATE W/ 1/2" X 8" A307 A.B.
<br />OR 1/2" dia. X 6" TITTEN H.D. @ 6"
<br />FROM CORNERS & JOINTS @ 32" O.C.
<br />
<br />-------------...
<br />,
<br />
<br />I
<br />'I
<br />, I
<br />',~
<br />\..._--------------
<br />
<br />
<br />SEE FND PLAN F
<br />FOOTING SIZE AND
<br />REINF.
<br />
<br />
<br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THE
<br />STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH THE
<br />FLORIDA BUILDING CODE, SECTION 1606 FOR 120 M.P.H. 3 SECOND
<br />GUST, EXPOSURE "B" WIND ZONE (2001 EDITION).
<br />
<br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE
<br />DATE IS SIGNED AND SEALED.
<br />
<br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION OF THIS
<br />DRAWING ONLY.
<br />
<br />INTERIOR SHEARWALL @ TRUSSES
<br />STEP-DOWN, WALL TO TRUSS
<br />
<br />NO SCALE REV. 9/03
<br />
<br />THIS DETAIL REQUIRED ONLY WHEN & WHERE
<br />SPECIFICALLY INDICATED BY THIS SYMBOL
<br />
<br />SHEAR CAP. 260#lIN.FT.
<br />
<br />It)
<br />o
<br />o C\/ .g
<br />.....J t'- CQ lJ.. 0 '.
<br />.....J I.!) Pd 0 LlJ 0
<br />~O) ~a~
<br />I 1.0 ffi g: g:j
<br /><( ~ CI... CIl I
<br />0<.0 ~:c~
<br />a: M CI...~ CI...
<br />O..-i ~o ~
<br />ri~ Q~~
<br />I I :.J.J::J
<br />::r:~ ~:Jo
<br />U u..: f-lLJ U,.. LUN
<br /><( ~-
<br />I.JJ CI:: I ::l:
<br />co <l:f-O
<br />o<.Oco~~~
<br />-1<.O~~<I:~
<br />-1..-iO)ViUz
<br />001.0 lLJ::l::J
<br />9;;I.ONO .CI::
<br />...... ~ O~ 0
<br />I <( <:: Z 'I
<br />U <l;- "-
<br />0...... CIlffi Q
<br />010 ~LUf-
<br />~..-i - Z U
<br />(Y)~ ~ai5
<br />x I <I:~~
<br />o UJ CI:: CI...
<br />COz OOw
<br />. 0 lLJ &l cr:
<br />O::r: [{J z >-
<br />a.: Cl. ~ i3 ~
<br /><0
<br />
<br />~
<br />o
<br />Z
<br />00::
<br />OW
<br />(j)W
<br />ZZ
<br /><:0
<br />Oz
<br />W
<br />
<br />
<br />
<br />o
<br />oM
<br />Z
<br />o
<br />(j)
<br />a:::
<br />W
<br />>
<br />
<br />10
<br />o
<br />o
<br />C';-J if)
<br />cj Z
<br />~ 0
<br />~ (j)
<br />~ >
<br />o W
<br />UJ a:::
<br />:::>
<br />(f)
<br />~
<br />
<br />w
<br />:::E ::l:
<br />. "- ~ p
<br />W lLJ 0 Ll... u...
<br />O~~:::!:Z
<br />:::! - 0 ::J
<br />I-x~cr:o
<br />o ::J Ll... U
<br />Oa:ozu
<br />Z&~~<(
<br /><1:0<1:5
<br />w1i:!fE~z
<br />t I"i <I: <:: CI:: 0
<br />'-JOuJ<l:O
<br /><: LlJ os:: CIl 0
<br />1-5;::6~
<br />o ::J lLJ-w
<br />og~ffi~
<br />u... t5 j2 ~ fE
<br />W~Qoo
<br />o CIl CI:: f-
<br />0:::: 12 zoos::
<br />_ ~ 1i: U
<br />........ lLJ ~ lLJ 0
<br />=:)~o~~
<br />::J ...J - CI::
<br />O'o...Jvio
<br />(j)CIl~...J'
<br />...J LlJ ...J 0
<br />~ ~ ~ ~
<br />
<br />U)
<br />-I
<br />-I
<br />
<br />-
<br />
<br />:c
<br />
<br />>-~
<br />0::-
<br />0>
<br />1--1--
<br />zU)
<br />wW
<br />>0::
<br />zO
<br />-0
<br />"'0
<br />~~
<br />00
<br />00
<br />1-1
<br />~ CO ~
<br />1000
<br />~C()~
<br />~ I-- ~
<br />L.() 0 ~
<br />oM -I ::>
<br />
<br />i
<br />L1) 00 N
<br />~ L1) N
<br />N I'- ....-1
<br />~ ~ ~
<br />
<br />w w l.l,J
<br />0... 0... ~
<br />!
<br />I
<br />I
<br />!
<br />
<br />~
<br />Q)
<br />.0
<br />C I
<br />~ C ..d:
<br />(5 g ~
<br />c :)
<br /><f. ~ :If
<br />Q) ., ~
<br />E .~ ~
<br />
<br />~~&
<br />
<br />I
<br />I
<br />
<br />-1
<br />-1
<br />~
<br />:2
<br />UJ
<br />f-
<br />r../)
<br />1.0
<br />o
<br />o
<br />
<br />~
<br />
<br />o
<br />
<br />
<br />
<br />o
<br />'<:t
<br />.....,
<br />~
<br />~
<br />(01"-
<br />~~
<br />irlU?
<br />-10)
<br />d~
<br />~~
<br />
<br /> (V) c:: a.:
<br />....-.. 0
<br />if) W c::
<br /> 0 LlJ zO
<br />.....J z u
<br /> 0<( 'W
<br />~ C\J () ~ ~
<br /> >- 0
<br /> z :r:
<br />W 0 J- 0<( en
<br />0 ::J
<br /> ~~
<br />.....J e::: 0 00
<br />.....J W c::
<br /> Z U LL.
<br /><: a ::J I-
<br />3: oz
<br /> LL J- ow
<br /> W c::en
<br />~ o...Zz
<br />2 >< ::c woo
<br />W C::u-
<br />I- a <.!J Wz~
<br />~ a:lw>
<br />if) I- 1= 15
<br />--- Z 0::: ~fi<(
<br /> >- 3 9
<br /> Z >- <(W c::
<br /> ~:r:o
<br /> ~ Q.. zl-ri
<br /> :s I- ...J
<br /> ::J <(
<br /> -.J 0 Cl.oc::
<br /> ~~~
<br /> Q. () :r:-W
<br /> f-3u
<br />
<br />SHEET NO.
<br />
<br />Cl.
<br />Cl::
<br />o
<br />()
<br />w
<br />:2
<br />o
<br />::r:
<br />(f)
<br />::J
<br />1.0
<br />o
<br />o
<br />N
<br />
<br />8-6 (8)
<br />
<br />LAST PLOT
<br />DATE: April 11, 2005
<br />
<br />@)
<br />
<br />I
<br />,
<br />I
<br />I
<br />NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALl
<br />DRAWINGS BEFORE CONSTRUCTION BEGINS, DANSCO ,
<br />ENGINEERING. llC IS RESPONSIBLE FOR THE STRUCTlJRAl !
<br />INTEGRITY OF THIS PROJECT ONLY. A.'W DISCREPANCY BETWEEN
<br />FiElD CONDITIONS. OTHER DESIGN PROFESSIOMlS' SHOP DR~WI~GS,
<br />CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND *EALED
<br />DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF DA.NSCO i
<br />ENGINEERING, LlC PRIOR TO THE COMMENCEMENT OF CONST~UCTION,
<br />
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />,
<br />\
<br />\
<br />\
<br />\
<br />\
<br />\
<br />,
<br />,
<br />,
<br />,
<br />
<br />
<br />,
<br />,
<br />/
<br />
<br />"
<br />,
<br />,
<br />,
<br />,
<br />\
<br />\
<br />\
<br />\
<br />\
<br />\
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />I
<br />/
<br />/
<br />/
<br />,
<br />,
<br />
<br />INTERIOR BEARING
<br />w/UPLlFT @ 4" STEP-DOWN
<br />
<br />NO SCALE REV. 9/24/04 TH
<br />THIS DETAIL REQUIRED ONLY WHEN & WHERE
<br />SPECIFICALLY INDICATED BY THIS SYMBOL
<br />UPLIFT VALUES - (DOUBLE SIDE CONNECTORS-DOUBLES VALUE BELOW)
<br />1 (EACH CONNECTOR) EACH STUD - 1075 LBS. PER TRUSS
<br />UPLIFT CAP 410 PLF (ANCHOR BOLTS)
<br />
<br />I
<br />
<br />PLACE SEAL HERE DE #250$88