Laserfiche WebLink
<br /> <br />u <br /> <br />r <br /> <br /> <br /> <br />2 x TOP PLATE <br /> <br />I <br />I <br />"" <br />I <br />BLOCKS <br /> r <br /> <br />PACER <br /> <br />2 x P.T. PLATE <br /> <br />. <br /> <br /> <br />1/4" MIN. SPACE <br />TRl USP TR 1 W/3 - 8d <br />COMMON NAILS @ EA <br />TRUSS OR BLOCKING <br />(NOTE: (2) 16d TOE NAILS <br />CAN BE USED IN LIEU OF <br />TRl STRAP) <br />2 x STUD @ 24" O.C. MAX. <br /> <br />SCALE: N.T.S. <br /> <br />TYPICAL INTERIOR NON-BEARING <br /> <br />REV. USP 07-28-04 TH <br /> <br /> <br />NOTE: <br />PLATE LENGTHS MUST BE <br />AT LEAST 8'-0" LONG. TYPICAL <br /> <br />-BOTTOM SPLICE <br />OVER STUD <br /> <br />"T" <br /> <br />CORNER <br /> <br />TYPICAL "T" AND CORNER DETAIL <br /> <br /> <br />SCALE: N.T.S. <br /> <br /> <br /> <br /> <br /> <br /> <br />REV. 9/03 <br /> <br />P.T. PLATE <br />SCALE: N.T.S. <br /> <br />2 - S.P.F. CONST. GRADE TOP PLATE <br />SPLICE MIN 48" APART <br />o NAIL AT BASE 2 ROWS 4" OIC STAGGER <br />W/8d COMMON NAIL <br />@ NAIL AT TOP PLATE 2 ROWS 4" OIC STAGGER <br />W/8d COMMON NAIL <br />@ NAIL OPENING PERIMETER @ 3" O.C. W/8d <br />COMMON NAIL <br />@ NAIL INT. AT 6" O.C. W/8d COMMON NAIL <br />@ STAGGER ALL VERT. JOINTS & NAIL @ 4" O.C. <br />w/8d COMMON NAIL <br />CD NO SPLICE @ HEADER - NAIL SHEATHING TO <br />HEADER W/frd COMMON NAIL@ 4" ole <br />2x4 P.T. BASE PLATE <br /> <br /> <br />-11- If -II <br />II II II <br />II II II <br />II II II <br /> <br />II <br />II <br />II II II <br />11_ lL JI_ <br />FLOOR SY ~MII <br />x8 P .T. SIEL PLAT <br />2 STORY ONLY) <br /> <br />WALL SHEATHING INSTALL. & NAILING SCHED. <br />NO SCALE REV. 5/12/04 <br /> <br /> <br />1 1 <br />:V: TRUSS/JOIST/RAFTER <br />1 1 <br />~--- -------,--, <br />I I (1)USPRT16T <br />: w/7-10d x 1 1/2" TO BOTH <br />__ L _ TRUSS AND DBL. TOP PLATE <br />2 - 2x4 TOP PLATE <br />CONST. GRADE SPF <br />USP SPT 24 w/6-10d <br />TO STUD & TO TOP PLATE <br /> <br />2x4 SPF STUDS @ 16" O.C. <br /> <br /> <br />A <br /> <br />USP SPT 22 w/ 4 -10d TO <br />STUD & 4-10d TO BASE PLATE <br />1/2" x 8" A307 A.B. OR 5/8"x 7" <br />WEDGE ANCH. w/2" WASHER 6" <br />FROM ENDS & JOINTS & @32" O.C. <br />MIN'lw/#3 PT PLATE <br /> <br /> <br />I <br />,- - - - - - - - ""- <br />, <br />, <br />" <br /> <br />I <br />r--------., <br />/ <br />/ <br />/ <br /> <br />: 1 <br />-.1 <br />1 <br />1 <br /> <br />SEE FND PLAN <br />FOR FOOTING <br />SIZE AND REINF. <br /> <br />INTERIOR BEARING <br />w/UPLlFT <br /> <br /> <br />NO SCALE REV. 09/13/04 TH <br />THIS DETAIL REQUIRED ONLY WHEN & WHERE <br />SPECIFICALLY INDICATED BY THIS SYMBOL <br />UPLIFT VALUES - (DOUBLE SIDE CONNECTORS-DOUBLES VALUE BELOW) <br />1 (EACH CONNECTOR) EACH STUD - 462 PLF <br /> <br />L <br /> <br />2- ROWS OF <br />10d @ 4" O/C <br />MAX. <br />10d @ 8" O/C <br /> <br />TOP PLATE SPLICE DETAIL <br />SCALE: N.T.S. 5/6/04 <br /> <br />PRE ENGINEERED WD TRUSSES @ 24" O.C. <br />INSULATION BAFFLE <br />BATT OR BLOWN INSULATION MIN. R-19 <br />TRUSS ANCHOR (SEE PLAN) <br />FIBERGLASS SHINGLE <br />ROOFING FELT <br />-APA RATED STRUCTURAL SHEATHING <br />MIN 7/16" FASTENED TO TRUSSES W/ <br />8d COMMON WIRE NAILS @ 4" O/C <br />_ _B'pUND_ARIES.~QjC EDGES & 8" O/C FIELD <br />~ METAL DRIP EDGE <br />2" X SUBFASCIA <br />CONT. VENTED ALUM SOFFIT <br />8" X 8" X 16" K.O. LINTEL BLOCK <br />W/l #5 DIA. REBAR & <br />FILLED SOLID W/GROUT <br />PRECAST "U" LINTEL <br />(SEE S/2A FOR LINTEL <br />SIZE & REINFORCEMENT) <br />FILL CELL -1 #5 DIA. REBAR W/ GROUT <br />@ ALL LOCATIONS SHOWN ON <br />FOUNDATION & FLOOR PLANS <br />ALUM FRAMED WINDOW W/ SCREEN <br />PRECAST CONC SILL <br />8" X 8" X 16" CONC. BLOCK <br />DECORATIVE FINISH <br />FTG. DOWEL #5 DIA. REBAR <br />18" IN CONC. -25" EXTEND (ACI 530) <br />ABOVE SLAB. ALL LOCATIONS <br />SHOWN ON FOUNDATION PLAN <br /> <br /> <br />1 <br />1/2" CD DRYWALL : <br />3/4" P.T. NAILER <br />1/2" DRYWALL <br />CURTAIN NAILER <br />1 X 4 P.T. @ WINDOWS <br />1 X 8 P.T. @ S.G.D. <br /> <br />MARBLE STOOL <br />1 X 2 P.T FURRING <br />R-3 FOIL INSUL ON EXT <br />BLOCK WALLS <br />1 X 4 P.T. BASE NAILER <br />WOOD BASE <br />3 1/2" CONC SLAB ~ <br />6 X 6 10/10 W.W.M. <br />6 MIL VISQUEEN <br /> <br />TREATED- <br />CLEAN FILL <br /> <br />SEE FND. PLAN FOR <br />FOOTING SIZE AND <br />REINF. <br /> <br />TYPICAL WALL SECTION <br />CONCRETE BLOCK REV. (STEM) 1/18/05 TH <br /> <br />I I <br />1 1 , <br />:: ~ TRUSS/RAFTER <br /> <br />~" , <br />: 1 /,' /,'" USP H1W20 W/24-10d x 1 1/2" <br />1 ... ,// TO BOTH TRUSS <br />__L_ ~ AND DBL. TOP PLATE/STUD <br />--------- 2-2x4TOPPLATE <br />CONST. GRADE SPF <br /> <br />USP SPT24 W/6-10d TO <br />STUD & TO TOP PLATE <br />2x4 SPF STUDS @ 16" O.C, <br /> <br /> <br />A <br /> <br />USP SPT22 W/4-10d TO <br />STUD & 4-10d TO BASE PLATE <br />#3 PT PLATE WI 1/2" x 8" A307 A.B. OR 1/2" dia. x 6" <br />TITEN H.D. @ 6" FROM CORNERS & JOINTS & @ 32" O.C. <br /> <br /> 2"x4" P.T. PLATE <br /> 1/2" x 8" ANCHOR <br /> BOLT W/ 2" x 1/8" FLAT 12 <br /> WASHER (TYP) <br />@ @ @ <br />J 32" ~ 32" J <br /> <br /> <br />SEE F~OOR PLAN <br /> <br />SEE FND PLAN FOR <br />FOOTING SIZE AND <br />REINF. <br /> <br /> <br /> <br />SCALE: N.T.S. <br /> <br /> <br />TRUSSES <br /> <br />USP RT 16 <br />@ 16" O.C. <br /> <br />----- <br />----- <br /> <br /> <br />2 - 2x4 CONST. GR. SP <br />TOP PLATE. SPLICE <br />24" APART MIN. <br /> <br /> UPLIFT CONNECTION CROSS-REFERENCE <br />USP STRUCTURAL CONNECTORS SIMPSON STRONG-TIE <br /> UPLIFT LATERAL FASTENERS CONNECTOR UPLIFT LATERAL FASTENERS <br />CONNECTOR r'~'~'~'yl CAPACITY CAPACITY ~.~.~.~, <br /> ;11 Y <br /> MASONRY APPLICATIONS MASONRY APPLICATIONS <br />HTA16 1500 590 13-10d x 11/2" META16 1450 335 7-10d x 11/2" <br />HTA20 1500 590 13-10d x 11/2" META20 1450 335 7-10d x 11/2" <br />HTT16 4290* - 18-16d HTT16 4175* - 18-16d <br />HTT22 5370* - 32-16d HTT22 5260* - 32-16d Sinkers <br />LUGT2 1850 16-10d & 5-1&4"X3" LGT2 2150 16-16d Sinkers & 7- <br />- Wed~e bol s - 1/4"x2 1/4" Titen <br />L TS19 1390* - 8-10d L TT19 1350* - 8-16d Sinkers <br />L TTI31 2650* - 18-10d x 11/2" L TTI31 2310* - 18-10d x 11/2" <br /> FRAME APPLICATIONS FRAME APPLICATIONS <br />RT7 585 170 10-8d x 11 2" H2.5 415 150 10-8d x 11/2" <br />RT16 1030 645 16-8d x 1 1 2" Hl0 990 525 16-8d x 11/2" <br />RT16-2 1030 390 16-8d x 1 1 2" Hl0-2 760 395 12-10d <br />SPT22 715 260 8-10d SPl 585 - 10-10d <br />SPT24 1075 260 12-10d SP2 1065 - 12-10d <br />SPT4 885 - 6-10d x 11/2" SP4 885 - 6-10d x 11/2" <br />SPTH4 1730 - 12-10d x 11/2" SPH4 1360 - 12-10d x 11/2" <br />MUGT15 3965 - 22-10d MGT 3965 - 22-10d <br />LUGT2 2260 - 32-10d LGT2 2050 - 30-16d Sinkers <br />HTW20 1530 95 20-10d HTS20 1450 - 20-10d <br />MSTA18 1275 - 14-10d LSTA18 1165 - 14-10d <br />MSTA24 1305 - 18-10d LSTA24 1235 - 18-10d <br />MSTA30 1635 - 22-10d LSTA30 1640 - 22-10d <br />MSTA36 1635 - 22-10d LSTA36 1640 - 24-10d <br /> HUNG APPLICATIONS HUNG APPLICATIONS <br />HUS26 1925 - 20-16d HUS26 1550 - 20-16d <br />THDH26-2 2605 - 30-16d HGUS26-2 2325 - 28-16d <br />HUS28 2570 - 30-16d HUS28 2000 - 30-16d <br />THDH210-2 3970 - 58-16d HGUS28-2 3220 - 48-16d <br /> <br />* CAPACITY IS BASED ON CONCRETE EMBEDMENT, REFER TO MANUFACTURER FOR GROUT FILLED <br />CMU <br />NOTES : <br />1) CONNECTOR CAPACITIES ARE FOR SYP, REFER TO MANUFACTURERS FOR ADDITIONAL <br />INFORMATION <br />2) DO NOT DRIVE NAILS THROUGH THE TRUSS PLATE ON THE OPPOSITE SIDE OF THE TRUSS, WHICH <br />COULD FORCE THE PLATE OFF THE TRUSS. <br /> <br />3-12d EA. END <br />OF BLOCKING <br /> <br />- - -- <br />- - -- <br /> <br />STRUCTURAL SHEATHING <br />(MIN. 7/16"). NAIL 3" O.C. <br />EDGES STAGGERED, & 6" O.C. <br />INTERIOR. <br /> <br />#3 PT PLATE W/ 1/2" X 8" A307 A.B. <br />OR 1/2" dia. X 6" TITTEN H.D. @ 6" <br />FROM CORNERS & JOINTS @ 32" O.C. <br /> <br />-------------... <br />, <br /> <br />I <br />'I <br />, I <br />',~ <br />\..._-------------- <br /> <br /> <br />SEE FND PLAN F <br />FOOTING SIZE AND <br />REINF. <br /> <br /> <br />TO THE BEST OF THE ENGINEER'S KNOWLEDGE AND BELIEF, THE <br />STRUCTURAL PLANS AND SPECIFICATIONS COMPLY WITH THE <br />FLORIDA BUILDING CODE, SECTION 1606 FOR 120 M.P.H. 3 SECOND <br />GUST, EXPOSURE "B" WIND ZONE (2001 EDITION). <br /> <br />THIS DRAWING AND DESIGN IS VALID FOR 12 MONTHS AFTER THE <br />DATE IS SIGNED AND SEALED. <br /> <br />SIGNED AND SEALED FOR THE STRUCTURAL PORTION OF THIS <br />DRAWING ONLY. <br /> <br />INTERIOR SHEARWALL @ TRUSSES <br />STEP-DOWN, WALL TO TRUSS <br /> <br />NO SCALE REV. 9/03 <br /> <br />THIS DETAIL REQUIRED ONLY WHEN & WHERE <br />SPECIFICALLY INDICATED BY THIS SYMBOL <br /> <br />SHEAR CAP. 260#lIN.FT. <br /> <br />It) <br />o <br />o C\/ .g <br />.....J t'- CQ lJ.. 0 '. <br />.....J I.!) Pd 0 LlJ 0 <br />~O) ~a~ <br />I 1.0 ffi g: g:j <br /><( ~ CI... CIl I <br />0<.0 ~:c~ <br />a: M CI...~ CI... <br />O..-i ~o ~ <br />ri~ Q~~ <br />I I :.J.J::J <br />::r:~ ~:Jo <br />U u..: f-lLJ U,.. LUN <br /><( ~- <br />I.JJ CI:: I ::l: <br />co <l:f-O <br />o<.Oco~~~ <br />-1<.O~~<I:~ <br />-1..-iO)ViUz <br />001.0 lLJ::l::J <br />9;;I.ONO .CI:: <br />...... ~ O~ 0 <br />I <( <:: Z 'I <br />U <l;- "- <br />0...... CIlffi Q <br />010 ~LUf- <br />~..-i - Z U <br />(Y)~ ~ai5 <br />x I <I:~~ <br />o UJ CI:: CI... <br />COz OOw <br />. 0 lLJ &l cr: <br />O::r: [{J z >- <br />a.: Cl. ~ i3 ~ <br /><0 <br /> <br />~ <br />o <br />Z <br />00:: <br />OW <br />(j)W <br />ZZ <br /><:0 <br />Oz <br />W <br /> <br /> <br /> <br />o <br />oM <br />Z <br />o <br />(j) <br />a::: <br />W <br />> <br /> <br />10 <br />o <br />o <br />C';-J if) <br />cj Z <br />~ 0 <br />~ (j) <br />~ > <br />o W <br />UJ a::: <br />:::> <br />(f) <br />~ <br /> <br />w <br />:::E ::l: <br />. "- ~ p <br />W lLJ 0 Ll... u... <br />O~~:::!:Z <br />:::! - 0 ::J <br />I-x~cr:o <br />o ::J Ll... U <br />Oa:ozu <br />Z&~~<( <br /><1:0<1:5 <br />w1i:!fE~z <br />t I"i <I: <:: CI:: 0 <br />'-JOuJ<l:O <br /><: LlJ os:: CIl 0 <br />1-5;::6~ <br />o ::J lLJ-w <br />og~ffi~ <br />u... t5 j2 ~ fE <br />W~Qoo <br />o CIl CI:: f- <br />0:::: 12 zoos:: <br />_ ~ 1i: U <br />........ lLJ ~ lLJ 0 <br />=:)~o~~ <br />::J ...J - CI:: <br />O'o...Jvio <br />(j)CIl~...J' <br />...J LlJ ...J 0 <br />~ ~ ~ ~ <br /> <br />U) <br />-I <br />-I <br /> <br />- <br /> <br />:c <br /> <br />>-~ <br />0::- <br />0> <br />1--1-- <br />zU) <br />wW <br />>0:: <br />zO <br />-0 <br />"'0 <br />~~ <br />00 <br />00 <br />1-1 <br />~ CO ~ <br />1000 <br />~C()~ <br />~ I-- ~ <br />L.() 0 ~ <br />oM -I ::> <br /> <br />i <br />L1) 00 N <br />~ L1) N <br />N I'- ....-1 <br />~ ~ ~ <br /> <br />w w l.l,J <br />0... 0... ~ <br />! <br />I <br />I <br />! <br /> <br />~ <br />Q) <br />.0 <br />C I <br />~ C ..d: <br />(5 g ~ <br />c :) <br /><f. ~ :If <br />Q) ., ~ <br />E .~ ~ <br /> <br />~~& <br /> <br />I <br />I <br /> <br />-1 <br />-1 <br />~ <br />:2 <br />UJ <br />f- <br />r../) <br />1.0 <br />o <br />o <br /> <br />~ <br /> <br />o <br /> <br /> <br /> <br />o <br />'<:t <br />....., <br />~ <br />~ <br />(01"- <br />~~ <br />irlU? <br />-10) <br />d~ <br />~~ <br /> <br /> (V) c:: a.: <br />....-.. 0 <br />if) W c:: <br /> 0 LlJ zO <br />.....J z u <br /> 0<( 'W <br />~ C\J () ~ ~ <br /> >- 0 <br /> z :r: <br />W 0 J- 0<( en <br />0 ::J <br /> ~~ <br />.....J e::: 0 00 <br />.....J W c:: <br /> Z U LL. <br /><: a ::J I- <br />3: oz <br /> LL J- ow <br /> W c::en <br />~ o...Zz <br />2 >< ::c woo <br />W C::u- <br />I- a <.!J Wz~ <br />~ a:lw> <br />if) I- 1= 15 <br />--- Z 0::: ~fi<( <br /> >- 3 9 <br /> Z >- <(W c:: <br /> ~:r:o <br /> ~ Q.. zl-ri <br /> :s I- ...J <br /> ::J <( <br /> -.J 0 Cl.oc:: <br /> ~~~ <br /> Q. () :r:-W <br /> f-3u <br /> <br />SHEET NO. <br /> <br />Cl. <br />Cl:: <br />o <br />() <br />w <br />:2 <br />o <br />::r: <br />(f) <br />::J <br />1.0 <br />o <br />o <br />N <br /> <br />8-6 (8) <br /> <br />LAST PLOT <br />DATE: April 11, 2005 <br /> <br />@) <br /> <br />I <br />, <br />I <br />I <br />NOTE: IT IS THE CONTRACTORS RESPONSIBILITY TO REVIEW ALl <br />DRAWINGS BEFORE CONSTRUCTION BEGINS, DANSCO , <br />ENGINEERING. llC IS RESPONSIBLE FOR THE STRUCTlJRAl ! <br />INTEGRITY OF THIS PROJECT ONLY. A.'W DISCREPANCY BETWEEN <br />FiElD CONDITIONS. OTHER DESIGN PROFESSIOMlS' SHOP DR~WI~GS, <br />CONTRACTORS' BUILDING METHODS, AND THESE SIGNED AND *EALED <br />DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF DA.NSCO i <br />ENGINEERING, LlC PRIOR TO THE COMMENCEMENT OF CONST~UCTION, <br /> <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />, <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />, <br />, <br />, <br />, <br /> <br /> <br />, <br />, <br />/ <br /> <br />" <br />, <br />, <br />, <br />, <br />\ <br />\ <br />\ <br />\ <br />\ <br />\ <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />/ <br />/ <br />/ <br />, <br />, <br /> <br />INTERIOR BEARING <br />w/UPLlFT @ 4" STEP-DOWN <br /> <br />NO SCALE REV. 9/24/04 TH <br />THIS DETAIL REQUIRED ONLY WHEN & WHERE <br />SPECIFICALLY INDICATED BY THIS SYMBOL <br />UPLIFT VALUES - (DOUBLE SIDE CONNECTORS-DOUBLES VALUE BELOW) <br />1 (EACH CONNECTOR) EACH STUD - 1075 LBS. PER TRUSS <br />UPLIFT CAP 410 PLF (ANCHOR BOLTS) <br /> <br />I <br /> <br />PLACE SEAL HERE DE #250$88 <br /> <br />------ <br />