Laserfiche WebLink
<br />FORM,600A-2004R <br /> <br />EnergyGauge@ 4.5.2 <br /> <br />FLORIDA ENERGY EFFICIENCY CODE <br />FOR BUILDING CONSTRUCTION <br /> <br />Florida Department of Community Affairs <br />Residential Whole Building Performance Method A <br /> <br />US1531SK- SIESTA KEY -1531 S.F. LIVING AREA3uilder: u.S. HOMES <br />iQ323 ln~ ,~ PlCI ~20; O(}~ + 1'1<a Perm~tting Office: c~ or 2--ep~rh\ \l <br />2..epn"1,h'i\l5, \4:.- Permit Number: 710tp <br />i-en(""'C...~ ~ Jurisdiction Number: (p \ \ ~OO <br />Central <br /> <br />New construction or existing New <br />Single family or multi-family Multi-family <br />NUmber of units, if multi-family 2 <br />NUmber of Bedrooms 2 <br />Is this a worst case? Yes <br />Conditioned floor area (fF) 1531 fF <br />Glass type 1 and area: (Label reqd. by 13-104.4.5 ifnot default) <br />a. U-factor: Description Area <br />(or Single or Double DEFAULT) 7a(Sngle Default) 153,0 fF <br />b. SHGC: <br />(or Clear or Tint DEFAULT) <br />8. Floor t)1les <br />a. Slab-On-Grade Edge Insulation <br />b. Raised Wood, Post or Pier <br />c. N/A <br />9. Wall types <br />a. Concrete, Int Insul, Exterior <br />b, Concrete, Int Insul, Adjacent <br />c. N/A <br />d. N/A <br />e. N/A <br />10. Ceiling types <br />a. Under Attic <br />b. N/A <br />c. N/A <br />I 1. Ducts <br />a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft <br />b. N/A <br /> <br />Project Name: <br />Address: <br />Cityl State: <br />Owner: <br />Climate Zone: <br /> <br />I. <br />2. <br />3. <br />4. <br />5. <br />6. <br />7. <br /> <br />7b. <br /> <br />(Clear) 153.0 ft2 <br /> <br />r-------- <br />12. Cooling systems <br />a. Central Unit <br /> <br />Cap: 28.8 kBtuIhr <br />SEER: 13,00 <br /> <br />R=O.O, 134.0(p) ft <br />R= 11.0, 124.0ft2 <br /> <br />R=4.1, 390.0 ft2 <br />R=4,1, 1668.0 ft2 <br /> <br />R=30.0, 828.0 ft2 <br /> <br />b. N/A <br /> <br />c, N/A <br /> <br />13. Heating systems <br />a. Electric Heat PUmp <br /> <br />Cap: 27,8 kBtuIhr <br />HSPF: 8.00 <br /> <br />b. N/A <br /> <br />c, N/A <br /> <br />14. Hot water systems <br /> <br />a, Electric Resistance <br /> <br />Cap: 40.0 gallons <br />EF: 0.92 <br /> <br />b, N/A <br /> <br />c. Conservation credits <br />(HR-Heat recovery, Solar <br />DHP-Dedicated heat pump) <br />15. HVAC credits <br />(CF-Ceiling fan, CV-Cross ventilation, <br />HF-Whole house fan, <br />PT -Programmable Thermostat, <br />MZ-C-Multizone cooling, <br />MZ-H-Multizone heating) <br /> <br />PT, _ <br /> <br />Glass/Floor Area: 0.10 <br /> <br />Total as-built points: 15651 <br />Total base points: 17367 <br /> <br />PASS <br /> <br /> <br />I hereby certify that the plans and sp <br />this calculation are in compliance <br />Code. <br />PREPARED BY: <br /> <br />DATE: <br /> <br />I hereby certify that this buildin , <br />with the Florida Energy Code. <br /> <br />OWNER/AGENT: <br /> <br />DATE: <br /> <br /> <br />Review of the plans and <br />specifications covered by this <br />calculation indicates compliance <br />with the Florida Energy Code. <br />Before construction is completed <br />this building will be inspected for <br />compliance with Section 553.908 <br />Florida Statutes, I' / J 5) <br /> <br />BUILDING OFFICIAL: AJ( <br /> <br />DATE: /D'-lS--en <br /> <br />and areas, see Summer & Winter Glass output on pages 2&4, <br />EnergyGauge@ (Version: FLRCSB v4.5,2) <br />