<br />FLORIDA ENERGY EFFICIENCY CODE
<br />FOR BUILDING CONSTRUCTION
<br />
<br />Florida Department of Community Affairs
<br />Residential Whole Building Performance Method A
<br />
<br />. u, S, 1531S, K- .SIESTA KEY -1531 S.F. LIVING AREA3uild~r:. . u.s. HOMES --~ I
<br />tR32.'3 rnQ\S'-' e Rd I \:i:.20, un',-\- \G~ Permlttmg Office: &.--'-'-t 0'" 2ee~rh, 'IS
<br />:3~~~hl\'5. r~ 3ol?'.>42. Pe~mi~~umber: -7\0(".0-_.
<br />i....e ~nc...o(" ~ Junsdlctlon Number: t..o ll(oDCJ
<br />Central __________________ '___________________ J
<br />
<br />FORM. 600A-2004R
<br />
<br />Project Name:
<br />Address:
<br />City, State:
<br />Owner:
<br />Climate Zone:
<br />
<br />I, New construction or existing New
<br />2. Single family or multi-family Multi-family
<br />3. Number of units, if multi-family 2
<br />4, Number of Bedrooms 2
<br />5. Is this a worst case? Yes
<br />6, Conditioned floor area (fF) 1531 fF
<br />7. Glass type I and area: (Label reqd. by 13-104.4.5 ifnot default)
<br />a, U-factor: Description Area
<br />(or Single or Double DEFAULT) 7a(Sngle Default) 153.0 ft2
<br />b. SHGC:
<br />(or Clear or Tint DEFAULT)
<br />8. Floor types
<br />a, Slab-On-Grade Edge Insulation
<br />b, Raised Wood, Post or Pier
<br />c, N/A
<br />9. Wall types
<br />a. Concrete, Int Insul, Exterior
<br />b. Concrete, Int Insul, Adjacent
<br />c. N/A
<br />d, N/A
<br />e, N/A
<br />10. Ceiling types
<br />a. Under Attic
<br />b. N/A
<br />c, N/A
<br />II. Ducts
<br />a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 150.0 ft
<br />b. N/A
<br />
<br />7b,
<br />
<br />(Clear) 153.0 ft2
<br />
<br />R=O.O, 134.0(p) ft
<br />R=11.0, 124.0ft2
<br />
<br />R=4.1, 390.0 ft2
<br />R=4.l, 1668,0 ft,
<br />
<br />R=30.0, 828.0 fF
<br />
<br />EnergyGauge@ 4.5.2
<br />
<br />]2, Cooling systems
<br />a, Central Unit
<br />
<br />Cap: 28.8 kBtu/hr
<br />SEER: 13.00
<br />
<br />b. N/A
<br />
<br />c, N/A
<br />
<br />13, Heating systems
<br />a, Electric Heat Pump
<br />
<br />Cap: 27,8 kBtuIhr
<br />HSPF: 8.00
<br />
<br />b, N/A
<br />
<br />c, N/A
<br />
<br />14. Hot water systems
<br />a. Electric Resistance
<br />
<br />Cap: 40,0 gallons
<br />EF: 0,92
<br />
<br />b. N/A
<br />
<br />c, Conservation credits
<br />(HR-Heat recovery, Solar
<br />DHP-Dedicated heat pump)
<br />15, HY AC credits
<br />(CF-Ceiling fan, CY-Cross ventilation,
<br />HF-Whole house fan,
<br />PT - Progranunable Thermostat,
<br />MZ-C-Multizone cooling,
<br />MZ-H-Multizone heating)
<br />
<br />PT, _
<br />
<br />Glass/Floor Area: 0.10
<br />
<br />PASS
<br />
<br />Total as-built points: 15651
<br />Total base points: 17367
<br />
<br />OWNER/AGENT:
<br />DATE:
<br />
<br />
<br />I hereby certify that the plans and s
<br />this calculation are in complian i
<br />Code,
<br />PREPARED BY:
<br />
<br />DATE:
<br />
<br />I hereby certify that this bui
<br />with the Florida Energy Code.
<br />
<br />1 Predominant glass type, For a
<br />
<br />BUILDING OFFICIAL:
<br />DATE: IO~(S -f7)
<br />
<br />
<br />Review of the plans and
<br />specifications covered by this
<br />calculation indicates compliance
<br />with the Florida Energy Code.
<br />Before construction is completed
<br />this building will be inspected for
<br />compliance with Section 553.908
<br />Florida Statutes,
<br />
<br />pe and areas, see Summer & Winter Glass output on pages 2&4.
<br />EnergyGauge@ (Version: FLRCSB v4.5,2)
<br />
|