My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-7164
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-7164
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:48:27 PM
Creation date
5/7/2008 9:49:23 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-7164
Building Department - Name
GALL BV LAND TRUST
Address
6020/6030/6038 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />GENERAL LIMITATIONS: <br /> <br />1. Fire classificatioo is not part of this acceptance. refer to a current Approved Roofing Materials <br />Directory for fire ratings of. this product. <br />2. Insulation may be"instaIled in multiple layers. The tint layer shall be attached in compliance with <br />Product Control Approval guidelines. All other layers shall be adhered in a full1Jl()pping of approved <br />asphalt applied within the EVT range and at a rate of 20-40 Ibs./sq.. or mechanically attached using. <br />the fastening pattern of the top layer . <br />3. All standard panel $izes.are . acceptable for mechaniCal attachment. When applied in approved <br />aspbalt. panel size shall be 4' x 4' maxilDUIIl. <br />4. An overlay. and/or recovery board insulation panel is required on all applications over closed cell <br />foam insulations when the base sheet is fully mopped. Ii no recovery board is used the base sheet <br />shall be applied using spot mopping with approved' ~haIt., 12" diameter circles, 24" o.c.; or strip <br />mopped 8" ribbons in three rows, one at each sidelap md one down the center of the sheet allowing a <br />continuous 8Ie& of ventilation. Encircling of the strips is nqt acceptable. A 6" break shall be placed <br />every 12' in each ribbon to allow cross ventilation. AsP,haIt application of either system shall be at a <br />minimum nue of I2lbsJsq. Note: Spot attaclaed syStems shaD be 6mited to a JIIR,QmuDl design <br />. pl'eIIIIIft of ~ psf. ' . <br />5. Fasteoer spacing for insulation attachment is based on a Miniumm Characteristic Force (F) value of <br />275 lbf.. as tested in compliance with Testing AppliCation Standard TAS IOS. lithe fastener value, <br />. as field-tested, are below 'ITS lb!. insulation attachment shall not be acceptable. <br />6. Fastener spacing for mechanical attachment of anchoilbase sheet or membrane attachment is based on <br />a minimum fastener resistance value in coojunction with the maximum design value listed within a <br />specific system. Should the fastener resistance be less than that required. as ~etennined by the <br />Building Official, a revised fastener spacing. prepared, signed and sealed by a Florida registered <br />Professional Engineer. Registered Architect, or Registered Roof Consultant may be submitted. Said <br />revised fastener spacing shall utilize the withdrawal resistaJice value taken from Testing Application <br />Standards TAS 105 and.calculations in compliance with Roofing Application Standard RAS 117. <br />7. Perimeter and. comer areas shall comply with the enhanced uplift pressure requirements of these <br />areas. Fastener densities shall be increased for both insulation and base sheet as calculated in <br />compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed <br />by a Florida registered Professional Engineer, Registered ArchiteCt, or Registered Roof Consultant <br />(When this limitation is spedftcaDy referred within this NOA, General Limitation #9 will not be <br />appJieable.) <br />8. All attachment and sizing of perimeter nailers, metal profile. and/or flashing termination designs shall <br />conform with Roofing Application Standard RAS III and applicable wind load requirements. <br />9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. <br />field, perimeters. and corners). Neither rational analysis, nor extrapolation shall be permitted for <br />enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). <br />(Wbea this limitation Is speeif'IC8Uy referred within this NOA, General limitation #7 wlll not be <br />applicable.) <br />10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building <br />Code and Rule 9B-72 of the Florida Administrative Code. <br />END OF THIS ACCEPTANCE <br /> <br />e <br /> <br />NOA No.: 03-0827.01 <br />Expiration Date: 01102108 <br />Approval Date: 05106I04 <br />Page 30 of 30 <br />
The URL can be used to link to this page
Your browser does not support the video tag.