Laserfiche WebLink
<br />Page 4 of 8 <br /> <br /> SPRINKLER FINISH (See Note 7) <br />K TYPE TEMP, BULB NATURAL I CHROME II WHITE'" <br /> LIQUID BRASS PLATED POLYESTER <br /> 135DF/57OC Orange <br /> PENDENT 155OF/68DC Red <br /> (TY1231) 1,2,3,5 <br /> and 175OFn9OC Yellow <br /> UPRIGHT 200oF/93OC Green <br />2.8 (TY1131) 286OF/141OC Blue <br />1/2' <br />NPT 135DF/57OC Orange <br /> RECESSED 155OF/68DC Red <br /> PENDENT <br /> (TY1231)* 175OFn9DC Yellow <br /> Figure 5 200DF/93OC Green 1,2,5 <br /> 135OF/57OC Orange <br /> RECESSED 155DF/68OC Red <br /> PENDENT <br /> (TY1231)- 175OFn9OC Yellow <br /> Figure 6 200oF/93OC Green <br /> 135OF/57OC Orange <br /> PENDENT 155OF/68OC Red <br /> (TY2231 ) <br /> and 175OFn9OC Yellow <br /> UPRIGHT 200oF/93OC Green <br />4.2 (TY2131) 286OF/141OC Blue <br />1/2' 1,2 <br />NPT 135OF/57OC Orange <br /> RECESSED 155OF/68OC Red <br /> PENDENT <br /> (TY2231 )* 175OFn9OC Yellow <br /> Figure 7 200oF/93OC Green <br /> 135OF/57OC Orange <br /> RECESSED 155OF/68OC Red <br /> PENDENT <br /> (TY2231)- 175OFn9OC Yellow <br /> Figure 8 200oF/93OC Green <br /> <br />NOTES: <br />1, Listed by Underwriters Laboratories. Inc, (UL) as Quick Response Sprinklers. <br />2, Listed by Underwriters Laboratories, Inc, for use in Canada (C-UL) as Quick Response <br />Sprinklers. <br />3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprin- <br />klers, <br />5, Approved by the City of New York under MEA 354-01-E. <br />7, Where Polyester Coated Sprinklers are noted to be UL and C-UL Listed, the sprin- <br />klers are UL and C-UL Listed as Corrosion Resistant Sprinklers. <br />* Installed with Style 10 (1/2* NPT) or Style 40 (3/4' NPT) 3/4' Total Adjustment <br />Recessed Escutcheon, as applicable. <br />.. Installed with Style 20 (1/2" NPT) or Style 30 (3/4" NPT) 1/2' Total Adjustment <br />Recessed Escutcheon, as applicable. <br />... Frame and Deflector only. Listings and approvals apply to color (Special Order), <br />N/A: Not Available <br /> <br />TABLE A <br />LABORA TORY LISTINGS AND APPROVALS <br />2.8 AND 4,2 K-FACTOR SPRINKLERS <br /> <br />held horizontally, a small air bubble <br />should be present. The diameter of the <br />air bubble is approximately 1/16 inch <br />(1.6 mm) for the 1350F/57"C to 3/32 <br />inch (2,4 mm) for the 2860F/1410C <br />temperature ratings, <br /> <br />A leak tight 1/2 inch NPT sprinkler joint <br />should be obtained with a torque of 7 <br />to 14 ft.lbs. (9.5 to 19,0 Nm). A maxi- <br />mum of 21 ft. Ibs. (28,5 Nm) of torque <br />may be used to install sprinklers with <br />1/2 NPT connections. A leak tight 3/4 <br /> <br />TFP17,1 <br /> <br />inch NPT sprinkler joint should'be ob- <br />tained with a torque of 10 to 20 ft.lbs, <br />(13,4 to 26,8 Nm). A maximum of 30 <br />fUbs. (40,7 Nm) of torque is to be used <br />to install sprinklers with 3/4 NPT con- <br />nections. Higher levels of torque may <br />distort the sprinkler inlet and cause <br />leakage or impairment of the sprinkler. <br /> <br />Do not attempt to make-up for insuffi- <br />cient adjustment in the escutcheon <br />plate by under- or over-tightening the <br />sprinkler. Readjust the position of the <br />sprinkler fitting to suit, <br /> <br />The Series TV -FRS Pendent and Up- <br />right Sprinklers must be installed in <br />accordance with the following instruc- <br />tions. <br /> <br />Step 1. Pendent sprinklers are to be <br />installed in the pendent position, and <br />upright sprinklers are to be installed in <br />the upright position. <br /> <br />Step 2. With pipe thread sealant ap- <br />plied to the pipe threads, hand tighten <br />the sprinkler into the sprinkler fitting. <br /> <br />Step 3. Tighten the sprinkler into the <br />sprinkler fitting using only the W- Type <br />6 Sprinkler Wrench (Ref. Figure 13). <br />With reference to Figures 1, 2, 3, and <br />4, the W- Type 6 Sprinkler Wrench is to <br />be applied to the sprinkler wrench <br />flats. <br /> <br />The Series TV-FRS Recessed Pen- <br />dent Sprinklers must be installed in <br />accordance with the following instruc- <br />tions. <br /> <br />Step A. After installing the Style 10. <br />20, 30, or 40 Mounting Plate, as appli- <br />cable, over the sprinkler threads and <br />with pipe thread sealant applied to the <br />pipe threads, hand tighten the sprin- <br />kler into the sprinkler fitting. <br /> <br />Step S. Tighten the sprinkler into the <br />sprinkler fitting using only the W- Type <br />7 Recessed Sprinkler Wrench (Ref. <br />Figure 14). With reference to Figure 1, <br />2, 3, and 4, the W-Type 7 Recessed <br />Sprinkler Wrench is to be applied to <br />the sprinkler wrench flats. <br /> <br />Step C. After the ceiling has been in- <br />stalled or the finish coat has been ap- <br />plied, slide on the Style 10, 20, 30, or <br />40 Closure over the Series TV-FRS <br />Sprinkler and push the Closure over <br />the Mounting Plate until its flange <br />comes in contact with the ceiling, <br />