Laserfiche WebLink
<br />TFP.171 <br /> <br />Page 5 of 8 <br /> <br /> . <br /> SPRINKLER FINISH (See Note 8) <br />K TYPE TEMP. BULB NATURAL I CHROME II WHITE*** LEAD <br /> LIQUID BRASS PLATED POLYESTER COATED <br /> 135OF/57OC Orange <br /> PENDENT 155OF/68OC Red <br /> (TY3231) 1, 2, 3, 4, 5, 6, 7 1,2,3,5 <br /> and 175OF179OC Yellow <br /> UPRIGHT 200oF/93OC Green <br />5,6 (TY3131) 286OF/141OC Blue <br />1/2' <br />NPT 135OF/57OC Orange <br /> RECESSED 155OF/68OC Red <br /> PENDENT 1,2,4,5 N/A <br /> (TY3231)* 175OF179OC Yellow <br /> Figure 9 200oF/93OC Green <br /> 135OF/57"C Orange <br /> RECESSED 155OF/68OC Red <br /> PENDENT 1, 2, 3, 4, 5 1,2,4,5 N/A <br /> (TY3231)" 175OF179OC Yellow <br /> Figure 10 200oF/93OC Green <br /> 135OF/57OC Orange <br /> PENDENT 155OF/68OC Red <br /> (TY4231) 1,2,5 <br /> and 175OF179OC Yellow 1,2,3,4,5,6,7 <br /> UPRIGHT 200oF/93OC Green <br />8,0 (TY4131) 286OF/141OC Blue <br />314' <br />NPT 135OF/57OC Green <br /> RECESSED 155OF/68OC Orange <br /> PENDENT 1,2,4,5 N/A <br /> (TY4231)* 175OF179OC Red <br /> Figure 11 200oF/93OC Yellow <br /> 135OF/57OC Orange <br /> RECESSED 155OF/68OC Red <br /> PENDENT 1,2,3,4,5 N/A <br /> (TY4231)** 175OF179OC Yellow <br /> Figure 12 200oF/93OC Green <br /> <br />NOTES: <br />1. Listed by Underwriters Laboratories, Inc. (UL) as Quick Response Sprinklers. <br />2. Listed by Underwriters Laboratories, Inc. for use in Canada (C-UL) as Quick Response Sprinklers. <br />3. Approved by Factory Mutual Research Corporation (FM) as Quick Response Sprinklers. <br />4, Approved by the Loss Prevention Certification Board (LPCB Ref. No. 007k/04) as Quick Response Sprinklers; however, the <br />LPCB does not rate the thermal sensitivity of recessed sprinklers. <br />5. Approved by the City of New York under MEA 354-01-E. <br />6. VdS Approved (For details contact Tyco Fire & Building Products, Enschede, Netherlands, Tel. 31-53-428-4444/Fax 31-53-428-3377). <br />7. Approved by the Loss Prevention Certification Board (LPCB Ref, No, 094a/06) as Quick Response Sprinklers. <br />8, Where Polyester Coated and Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as <br />Corrosion Resistant Sprinklers. Where Lead Coated Sprinklers are noted to be FM Approved, the sprinklers are FM Approved as a <br />Corrosion Resistant Sprinklers. <br />* Installed with Style 10 (1/2" NPT) or Style 40 (3/4' NPT) 3/4" Total Adjustment Recessed Escutcheon, as applicable. <br />** Installed with Style 20 (1/2' NPT) or Style 30 (314' NPT) 1/2' Total Adjustment Recessed Escutcheon, as applicable. <br />..* Frame and Deflector only. Listings and approvals apply to color (Special Order). <br />N/A: Not Available <br /> <br />TABLE B <br />LABORATORY LISTINGS AND APPROVALS <br />5.6 AND 8.0 K-FACTOR SPRINKLERS <br />