<br />
<br />A
<br />
<br />EXTERIOR
<br />
<br />INTI:RIOR
<br />
<br />PRESSURE TREATED
<br />~BUCKSTRIP (MiN. 2$'
<br />AS SHOWN)
<br />
<br />SHIM AS NEEDED
<br />WINDOW
<br />fASTENER
<br />
<br />.~
<br />. :q'"
<br />~ ...:~~.
<br />EXTERIOR
<br />
<br />flLL INTI:RIOR VOID Wffit
<br />MINIMAL EXPANDING fOAM
<br />- If PER CODE
<br />
<br />INST ALLA nON DET A1LS FOR FIN WINDOWS IN
<br />WINDZONES OF 150Y1PH OR LESS (DETAIL B)
<br />
<br />Installation fasteners for windows should be a
<br />
<br />minimum It" nail or It" wood screws, with an embedment of
<br />at least 1 ", Fasteners should be located at a maximum of 4"
<br />from each corner and 18" O.C. for screws and 9" O.C. for
<br />nails. It is recommended that all screws or nails be sealed to
<br />prevent infiltration of air and water. Product may be shimmed
<br />as necessary.
<br />Flexible flashing should be installed in a
<br />weatherboard fashion. The top layer should overlay any layer
<br />beneath it. The weather resistant barrier should then cover the
<br />flexible flashing at the header. The application of the weather
<br />resistant barrier will vary based on when it is installed. Ifit is
<br />installed after the window, it should be tucked under the sill
<br />
<br />Ifusing It" thick or greater wood buckstrips (not shown): flashing and overlap the jambs and head flashing,
<br />Window installation fasteners should be a minimum #8 Xl" I '1WR [j) AillR1C^"
<br />!\RCllIT'cCl1.;RAL
<br />wood screws, installed through the window into the buckstrip. j ~~~CNRf:S
<br />Window may be shimmed as necessary, provided a minimum """'DEll
<br />1 e wtn ow ~lcte In IS awmg \s mten c or use on typIC constructIOn. It 13 t e responsi i It) 0 0 t.-TS to e:termme i tt IS app lea e. A lua as g, vapor
<br />barriers, etc. may be specified by the project dTchitoct. Wind and design pressures 'vary within each S:8te ~d count)'. All products manufactured by Nu.A..ir Inc. meet a
<br />minim= of 110 mph (RJO DP) wind load requirements (per AAM.. 101); please check local hui1ding codes for exact requiremems. Aoove detail. ,hown for Single Hung
<br />window. For installation of Awning. Honzontal Roller, or Picture/Designer window! use the same specifications as :lhown above for the Single Hung, provided that an
<br />rc- W1ched fTame installation holes ~e utilized and with !.he above mentioned s....'Tew size e and s aein .
<br />
<br />I~STALLAnON DETAILS FOR FLA."JGE W1J\DOWS IN
<br />WINDZO~ES OF 150MPH OR LESS (DETAIL A)
<br />
<br />Buckstrips must be set in a bead of sealant. The exterior joint
<br />bet\veen the buckstrip and masonry must also be sealed.
<br />Buckstrips shall run the entire length of the rough opening. A
<br />buckstrip is not necessary at the sill ifit is pre-cast. All gaps
<br />must be sealed. Buckstrips should be pressure treated yellow
<br />pine, spruce or comparable lumber. In accordance with the
<br />Florida Building Code, a taper, or bevel on the buck is
<br />acceptable if the window frame is fully supported by the
<br />buckstrip at both the interior and exterior.
<br />
<br />If using i" thick wood buckstrips:
<br />Installation fasteners should be a minimwn f5" X 2i" masonry
<br />screws, installed through the window and buckstrip, into the
<br />masonry. Window may be shimmed as necessary, provided a
<br />minimwn screw embedment of li" is maintained in the
<br />masonry. Fasteners should be located a ma'(imwn of 4" from
<br />each corner and maximum of 18" O.c. It is recommended that
<br />fasteners not be installed through the sill of the window. The
<br />actual size of the buckstrips should be no less than t" X 2*".
<br />
<br />JAMBS
<br />
<br />
<br />
<br />,F NECESSARY,
<br />USE SHIMS
<br />WHEN
<br />INSTAlliNG TO
<br />KEEP PLUMB ole
<br />l.EYEL
<br />
<br />NO
<br />FASTENERS
<br />THROUGH
<br />Sill.
<br />
<br />. SEAUlNT BEAD
<br />
<br />SILL
<br />
<br />
<br />HEADER
<br />
<br /><l.
<br />
<br />PRESSURE TREATED
<br />~BUCKSTRIP (MIN. 2$'
<br />AS SHOWN)
<br />
<br />SHIM AS NEEDED
<br />WINDOW
<br />fASTENER
<br />flLL INTI:RIOR VOID WITH
<br />MiNIMAL EXPANDING fOAM
<br />- IF PER CODE
<br />
<br />EXTERIOR
<br />
<br />JAMBS
<br />
<br />IF NECESSARY,
<br />USE SHIMS
<br />WHEN
<br />INSTAlliNG TO
<br />KEEP PLUMB ole
<br />l.EYEL
<br />
<br />
<br />
<br />NO
<br />FASTENERS
<br />THROUGH
<br />SIU.
<br />
<br />. SEAUINT BEAD
<br />
<br />SILL
<br />
<br />
<br />iNSTALLATION DETAILS FOR ~ON-IMPACT, FLANGE, Se'oiGLE
<br />HUNG WIl\DOWS IN WI~DlONES OF 150MPH OR LESS (per mc 2001)
<br />
<br />Buckstrips must be set in a bead of sealant. The exterior joint
<br />between the buckstrip and masonry must also be sealed.
<br />Buckstrips shall run the entire length of the rough opening. A
<br />buckstrip is not necessary at the sill if it is pre-cast. All gaps must
<br />be sealed. Buckstrips should be pressure treated yellow pine,
<br />spruce or comparable lumber. In accordance with the Florida
<br />Building Code, a taper, or bevel on the buck is acceptable if the
<br />window frame is fully supported by the buckstrip at both the
<br />interior and exterior.
<br />Ifusing t" thick wood buckstrips:
<br />Installation fasteners should be a minimum f5" X 21" masonry
<br />screws, installed through the window and buckstrip, into the
<br />masonry. Window may be shimmed as necessary, provided a
<br />minimum screw embedment of It" is maintained in the masonry.
<br />Fasteners should be located a maximum of 4" from each comer
<br />and ma'(imum of 18" O.c. It is recommended that fasteners not be
<br />installed through the sill of the window. The actual size of the
<br />buckstrips should be no less than t" X 2i".
<br />If using l~" thick or greater wood buckstrips (not shown):
<br />Window installation fasteners should be a minimum #10 X I!"
<br />wood screws, installed through the wiodow into the buckstrip.
<br />Window may be shimmed as necessary, provided a minimum
<br />screw embedment of It" is maintained in the buckstrip. Window
<br />fasteners should be located a maximum of 4" front each comer and
<br />maximum of 18" O.C. It is recommended that fasteners not be
<br />installed through the sill of the window. The actual size of the
<br />buckstrips should be no less than 1~" X 2*". Buckstrips should be
<br />installed using minimum ~" X 21" masonry screws, to maintain
<br />It" embedment, and be 18" O.C.
<br />
<br />j'~WR. [j)~~~~~RAL
<br />M........\....1".ACTt;!U:.S
<br />ASSOC1A nON
<br />\iE\tHER
<br />
<br />The window depicted in this drawing is intended for use on typical construction. [t is the
<br />responsibility of others to determine if it is applicable. Additional flashing, vapor barriers, etc.
<br />may be specified by the project architect. \Vind and design pressures vary within each state and
<br />county. All products manufactured by NuAir Inc. meet a minimum of 110 mph (R30 DP) wind
<br />load requirements (per AAYfA 10 I); please check local building codes for exact requirements.
<br />
<br />Tampa, FL .(800) 282-6627.www.NuAircom
<br />
<br />
<br />INTI:RIOR
<br />
<br />INTI:RIOR
<br />
<br />PRESSURE TREATED
<br />BUCKSTRIP (MIN. 2$'
<br />AS SHOWN)
<br />
<br />flLL INTI:RIOR VOID Wffit
<br />MINIMAL EXPANDING FOAM
<br />- IF PER CODE
<br />
<br />JAM BS
<br />
<br />NO
<br />FASTENERS
<br />THROUGH
<br />SILL
<br />
<br />If NECESSARY,
<br />USE SHIMS
<br />WHEN
<br />INSTAlliNG TO
<br />KEEP PLUMB ole
<br />l.EYEL
<br />
<br />. SEAUINT BEAD
<br />
<br />SILL
<br />
<br />:>
<br />:c
<br />
<br />
<br />1I1 ,.....\t}JUCA.\j
<br />ARCHITECT\.., R.A1.
<br />MA......L1-'r\CTI...RES
<br />ASSOCIA no~
<br />\iJ::..\o1lJtR
<br />
<br />The window depicted in this drawing is intended for use 00 typical construction. It is the
<br />responsibility of others to determine if it is applicable, Additional flashing, vapor barriers, etc.
<br />may be specified by the project architect. Wind and design pressures vary withio each state and
<br />county. All products manufactured by NuAir Inc. meet a minimum of 110 mph (R30 DP) wind
<br />load requirements (per AA\1A 1 OJ); please check local building codes for exact requirements.
<br />
<br />4'fWR
<br />
<br />n
<br />>>
<br />:e
<br />~
<br />
<br />D
<br />..,.
<br />
<br />:0
<br />D
<br />
<br />..
<br />
<br />Tampa. FL -(800) 282-6627.www.NuAircom
<br />
<br />C
<br />aJ
<br />-:t
<br />
<br />
<br />fU)(IBLE
<br />FlASHING
<br />
<br />..,.
<br />.-
<br />
<br />WEATHER -
<br />RESISTANT-
<br />BARRIER
<br />
<br /><:)
<br />::J
<br />
<br />a
<br />31
<br />a
<br />z:
<br />I
<br />
<br />flLL INTI:RIOR VOID W1ll-t
<br />MINIMAL EXPANDING fOAM
<br />- IF PER C0DE
<br />
<br />~
<br />:n
<br />-
<br />>-
<br />-'
<br />
<br />IF NECESSARY,
<br />USE SHIMS
<br />WHEN
<br />INSTAlliNG TO
<br />KEEP PLUMB ole
<br />l.EVEL
<br />
<br />I
<br />.l-
<br />I
<br />J.J
<br />-'
<br />~
<br />z:
<br />:n
<br />~
<br />~
<br />
<br />JAMBS
<br />
<br />FINISHED
<br />SILL
<br />
<br />EXTERIOR
<br />FACADE
<br />
<br />-
<br />~
<br />z:
<br />z:
<br />J.J
<br />-'
<br />-
<br />.-
<br />>>
<br />:D
<br />~
<br />:;)
<br />
<br />:n
<br />-
<br />:n
<br />:.:::
<br />g
<br />-'
<br />:c
<br />-
<br />
<br />. SEAUINT BEAD
<br />o SEALANT BEAD IF FlASHING IS NOT ADHESNE
<br />
<br />
<br />IMT ALLA TION DETAILS FOR NON-I~PACT, FLMGE, A 'NNI~G
<br />WI:--IDOWS IN WI~DlO~ES OF 150MPH OR LESS (per FBC 2001)
<br />
<br />Buckstrips must be set in a bead of sealant. The exterior joint
<br />between the buckstrip and masonry must also be sealed.
<br />Buckstrips shall run the entire length of the rough opening. A
<br />buckstrip is not necessary at the sill if it is pre-cast. All gaps must
<br />be sealed. Buckstrips should be pressure treated yellow pine,
<br />spruce or comparable lumber. In accordance with the Florida
<br />Building Code, a taper, or bevel on the buck is acceptable if the
<br />window frame is fully supported by the buckstrip at both the
<br />interior and exterior.
<br />I fusing t" thick wood buckstrips:
<br />Installation fasteners should be a minimum ii" X 2t" masonry
<br />screws, installed through the window and bucks trip, into the
<br />masonry. Window may be shimmed as necessary, provided a
<br />minimwn screw embedment of It" is maintained in the masonry.
<br />Fasteners should be located a maximum of 4" from each comer
<br />and ma'(imum of 18" O.C. [t is recommended that fasteners not be
<br />installed through the sill of the window. The actual size of the
<br />buckstrips should be no less than i" X 2i".
<br />If using l~" thick or greater wood buckstrips (not shown):
<br />Window installation fasteners should be a minimum #10 X It"
<br />wood screws, installed through the wiodow into the buckstrip.
<br />Window may be shimmed as necessary, provided a minimum
<br />screw embedment of It" is maintained in the buckstrip. Window
<br />fasteners should be located a maximum of 4" from each corner and
<br />maximum of 18" O.C. It is recommended that fasteners not be
<br />installed through the sill of the window. The actual size of the
<br />buckstrips should be no less than I!" X 2i". 13uckstrips should be
<br />installed using minimwn f5" X 21" masonry screws, to maintain
<br />It" embedment, and be 18" O,C.
<br />
<br />iNSTALLATIO:o-l DETAILS FOR NONIMPACT, FI:--I, HORIl. ROL-
<br />LER WINDOWS 1:--1 WINDlONES OF 150MPH OR LESS (per FI3C 2001)
<br />
<br />Window Installation:
<br />
<br />Installation fasteners for windows should
<br />
<br />be a minimwn 11", 4d naIl or 6 x I!" drywall screw,
<br />
<br />with an embedment of at least It". Fasteners
<br />should be located at a maximum of 4" from each
<br />corner and 18" O.C. for screws and 9" O.C. for
<br />nails.
<br />[t is recommended that all screws or
<br />nails be sealed to prevent infiltration of air and
<br />water. Product may be shimmed as necessary.
<br />
<br />Weatherproofing:
<br />
<br />Flexible tlashing should be installed in a
<br />weatherboard fashion. The top layer should overlay
<br />any layer beneath it. The weather resistant barrier
<br />should then cover the flexible flashing at the
<br />header.
<br />1ne application of the weather resistant
<br />barrier will vary based on when it is installed. Ifit
<br />is installed after the window, it should be tucked
<br />under the sill flashing and overlap the jambs and
<br />head flashing.
<br />
<br />lI1"MbRJCA"
<br />ARCHlTECTLRAL
<br />M.....~U1-I'Cn.RES
<br />ASSOCLJ.. nUN
<br />ME\lHER
<br />
<br />The window depicted in this drawing is intended for use on typical construction. [t is the
<br />responsibility of others to detennine if it is applicable. Additional tlashing, vapor barriers, etc.
<br />may be specified by the project architect. Wind and design pressures vary within each state and
<br />county, All products manufactured by NuAir Inc, meet a minimum of 110 mph (R30 DP) wind
<br />load requirements (per AA\1A 101); please cbeck loeal building codes for exact requirements.
<br />
<br />it "L WR
<br />
<br />Tampa, FL -(800) 282-6627-www.NuAir.com
<br />
<br />.~
<br />
<br />io!!:
<br />
<br />
<br />
<br />screw embedment ofl" is maintained in the buckstrip. Window
<br />fasteners should be located a maximum of 4" from each comer
<br />and maximum of 18" O.C. It is recommended that fasteners not
<br />be installed through the sill of the window. The actual size of
<br />the buckstri ps should be no less than 1 t" X 2 t". Buckstrips
<br />should be installed using minimum f5" X 21" masonry screws,
<br />to maintain It" embedment, and be 18" O,C.
<br />
<br />B
<br />
<br />fU)(IBLE
<br />FL4SHING
<br />
<br />WEATHER
<br />RESISTANT
<br />BARRIER
<br />
<br />EXTERIOR
<br />
<br />WEATHER
<br />RESISTANT
<br />BARRIER
<br />IBLE WEATHER
<br />FL4SHING RESISTANT
<br />BARRIER
<br />
<br />EXTERIOR
<br />FACADE
<br />
<br />JAMBS
<br />
<br />
<br />
<br />fU)(IBLE
<br />FL4SHING
<br />
<br />WEATHER
<br />RESISTANT-
<br />BARRIER
<br />
<br />FlI..L INTI:RIOR VOID Wffit
<br />MINIMAL EXPANDING fOAM
<br />- IF PER CODE
<br />
<br />IF NECESSARY.
<br />USE SHIMS
<br />WHEN
<br />INSTAlliNG TO
<br />KEEP PLUMB ole
<br />l.EYEL
<br />
<br />EXTERIOR
<br />
<br />WEATHER
<br />RESISTANT
<br />BARRIER
<br />IBLE WEATHER
<br />FL4SHING RESISTANT
<br />BARRIER
<br />
<br />EXTERIOR _
<br />fACADE
<br />
<br />flNISHED
<br />SILL
<br />
<br />JAMBS
<br />
<br />WINDOW
<br />fASTENER
<br />
<br />. SEALANT BEAD
<br />OSEAUINT BEAD IF FlASHING IS NOT ADHESNE
<br />
<br />HEADER
<br />
<br />WINDOW
<br />FASTENER
<br />WOOD
<br />FRAME
<br />HEADER
<br />
<br />flLL INTI:RIOR VOID W1ll-t
<br />MINIMAL D:PANDING FOAM
<br />- IF PER CODE
<br />
<br />If NECESSARY,
<br />USE SHIMS
<br />Wl-IEN
<br />INSTAlliNG TO
<br />KEEP PLUMB ole
<br />l.EYEL
<br />
<br />flNISHED
<br />SILL
<br />
<br />. SEALANT BEAD
<br />OSEAUINT BEAD IF FlASHING IS NOT ADHESNE
<br />
<br />Ii'iSTALLATIO:o-l DETAILS FOR NON-IMPACT, FIN, SINGLE
<br />HUl\G WI~DOWS IN WINDlOl\ES OF 150MPH OR LESS (per mc 20(1)
<br />
<br />Window Installation:
<br />
<br />Installation fasteners for windows should
<br />be a minimum I!", 4d nail or 6 it I!" drywall screw,
<br />with an embedment of at least I!". Fasteners
<br />should be located at a maximum of 4" from each
<br />corner and 18" O.C. for screws and 9" O.C. for
<br />nails.
<br />It is recommended that all screws or
<br />nails be sealed to prevent infiltration of air and
<br />water. Product may be shimmed as necessary.
<br />
<br />Weatherprooting:
<br />
<br />Flexible l1ashing should be installed in a
<br />weatherboard fashion. 1ne top layer should overlay
<br />any layer beneath it. The weather resistant barrier
<br />should then cover the flexible flashing at the
<br />header.
<br />The application of the weather resistant
<br />barrier will vary based on when it is installed. Ifit
<br />is installed after the window, it should be tucked
<br />under the sill flashing and overlap the jambs and
<br />head flashing.
<br />
<br />!'~ t4AR 1I1~=~
<br />, ~ ASSOClAl101\i
<br />MEM8Ell
<br />
<br />The window depicted in this drawing is intended for use on typical construction. It is the
<br />responsibility of others to determine ifit is applicable. Additional flashing, vapor barriers, etc.
<br />may be specified by the project architect. Wind and design pressures vary within each state and
<br />county. All products manufactured by NuAir Inc. meet a minimum of 110 mph (R30 DP) wind
<br />load requirements (per AAMA 101); please check local building codes for exact requirements.
<br />
<br />
<br />Tampa, FL .(800) 282-6627.www.NuAircom
<br />
<br />
<br />fU)(IBLE
<br />FVSHING
<br />
<br />WEATHER
<br />RESISTANT
<br />BARRIER
<br />
<br />EXTERIOR
<br />fACADE
<br />
<br />RIGID FlASHING ~
<br />(OPT.. BY OTHERS)
<br />
<br />flLL INTI:RIOR VOID W1ll-t
<br />MiNIMAL D:PANDING fOAM
<br />- IF PER CODE
<br />
<br />IF NECESSARY,
<br />USE SHIMS
<br />WHEN
<br />INSTAlliNG TO
<br />KEEP PLUMB ole
<br />l.EYEL
<br />
<br />.
<br />~F1..D(IBLE
<br />FL4SHING
<br />
<br />flNISHED
<br />SILL
<br />
<br />EXTERIOR
<br />
<br />JAMBS
<br />
<br />EXTERIOR
<br />fACADE
<br />
<br />. SEALANT BEAD
<br />OSEAUINT BEAD IF FlASHING IS NOT ADHESNE
<br />
<br />
<br />I~STALLATIO:-l DETAlLS FOR NON-IMPACT, FIN, AW~I~G
<br />WIl\DOWS IN WI~DlONES OF 150MPH OR LESS (per FBC 200 I)
<br />
<br />Window Installation:
<br />
<br />Installation fasteners for windows should
<br />be a minimum 1!-", 4d nail or 6 x I!" drywall screw,
<br />with an embedment of at least I!". Fasteners
<br />should be located at a ma1\.imum of 4" from each
<br />comer and 18" O.C. for screws and 9" O.C. for
<br />nails.
<br />[t is recommended that all screws or
<br />nails be sealed to prevent infiltration of air and
<br />water. Product may be shimmed as necessary.
<br />
<br />Weatherprooting:
<br />
<br />Flexible flashing should be installed in a
<br />weatherboard fashion. The top layer should overlay
<br />any layer beneath it. The weather resistant barrier
<br />should then cover the flexible flashing at the
<br />header.
<br />The application of the weatber resistant
<br />barrier will vary based on when it is installed. Ifit
<br />is installed after the window, it should be tucked
<br />under the silll1ashing and overlap the jambs and
<br />head flashing.
<br />
<br />[j) A.\t1EH.JCAN
<br />ARCHI'-'::...cn.RAl
<br />IW. Nl:FA(''1'\..;RES
<br />ASSOCIA'llO]lt,'
<br />Ml:;M8J:.:R
<br />
<br />The window depicted in this drawing is intended for use on typical construction. It is the
<br />responsibility of others to determine if it is applicable. Additional flashing, vapor barriers, etc.
<br />may be specified by the project architect. Wind and design pressures vary within each state and
<br />county. All products manufactured by NuAir Inc. meet a minimum of 110 mph (R30 DP) wind
<br />load requirements (per AA.\1A 10 I); please check local building codes for exact requirements.
<br />
<br />!'LWR
<br />
<br />Tampa, FL .(800) 282-6627.www.NuAircom
<br />
<br />
<br />fU)(IBLE
<br />FL4SHING
<br />
<br />WEATHER -
<br />RESISTANT
<br />BARRIER
<br />
<br />flLL INTI:RIOR VOID W1ll-t
<br />MINIMAL D:PANDING FOAM
<br />- IF PER COOE
<br />
<br />IF NECESSARY,
<br />USE SHIMS
<br />WHEN
<br />INSTAlliNG TO
<br />KEEP PLUMB ole
<br />l.EYEL
<br />
<br />WEATH
<br />RESISTANT
<br />BARRIER
<br />EXTERIOR FL4S~~ Js~sf~
<br />JAM B S BARRIER
<br />EXTERIOR
<br />rACADE
<br />
<br />
<br />flNISHED
<br />SIlL
<br />
<br />WINDOW
<br />fASTENER
<br />
<br />. SEALANT BEAD
<br />OSEAUINT BEAD IF FlASHING IS NOT ADHESNE
<br />
<br />
<br />INSTALLATION DETAILS FOR l\ON-I~PACT, FIN, FIXED
<br />Wll\DOWS IN WI~DlONES OF 150MPH OR LESS (per FBC 2001)
<br />
<br />Window Installation:
<br />
<br />Installation fasteners for windows should
<br />be a minimum l~", 4d nail or 6)( It" drywall screw,
<br />with an embedment of at least It". Fasteners
<br />should be located at a maximum of 4" from each
<br />corner and 18" O.C. for screws and 9" O.C. for
<br />nails.
<br />It is recommended that all screws or
<br />nails be sealed to prevent infiltration of air and
<br />water. Product may be shimmed as necessary.
<br />
<br />Weatherproofing:
<br />
<br />Flexible flashing should be installed in a
<br />weatherboard fashion. The top [ayeI' should overlay
<br />any layer beneath it. The weather resistant banier
<br />should then cover the t1exible flashing at the
<br />header.
<br />The application of the weather resistant
<br />barrier will vary based on when it is installed. If it
<br />is installed after the window, it should be tucked
<br />under the sill flashing and overlap the jambs and
<br />head flashing.
<br />
<br />1I1 'MEJOC^"
<br />AllCHlTOCn.:RA.L
<br />,!l.l....:...-L;l,Acn:tu:s
<br />-\SSOC1A nON
<br />MEMBER
<br />
<br />The \\indow depicted in this drawing is intended for use on typical construction. It is the
<br />responsibility of others to determine if it is applicable. Additional flashing, vapor barriers, etc.
<br />may be specified by the project architect. Wind and design pressures vary within each state and
<br />county. All products manufactured by NuAir loco meet a minimum of 110 mph (R30 DP) wind
<br />load requirements (per AA.\1A 101); please check local building codes for exact requirements.
<br />
<br />!'LWR
<br />
<br />HEADER
<br />
<br />.'<1"
<br />
<br />SERlES
<br />0H2/3 HR
<br />
<br />_J\ ~OR
<br />~.V" .
<br />: '<l.~V/I/'H
<br />< '. "l.
<br />
<br />....,4
<br />4;'
<br />'.~ .
<br />EXTERIO: ~
<br />
<br />I
<br />.'.~
<br />(~ I
<br />~ . INTI:RIOR
<br />
<br />PRESSURE TREATED
<br />~UCKSTRIP (MIN. 2$'
<br />AS SHOWN)
<br />
<br />" SHIM AS NEEDED
<br />WiNDOW
<br />fASTENER
<br />
<br />--
<br />
<br />" '"
<br />L
<br />~
<br />v
<br />flLL INTI:RIOR VOID W1ll-t
<br />MINIMAL EXPANDING fOAM
<br />- IF PER CODE
<br />
<br />J7l
<br />:J.-. <
<br />.~
<br />
<br />.,~.~
<br />-q , '. .
<br />-~E:XTIRIOR
<br />
<br />^
<br />
<br />
<br />~
<br />V'
<br />...,... NO
<br />fASTENERS
<br />TI-iROVGH
<br />SILL
<br />
<br />^
<br />
<br />
<br />
<br />/~
<br />
<br />JAM BS
<br />
<br />IF NECESSARY,
<br />USE SHIMS
<br />WHEN
<br />INSTAlliNG TO
<br />KEEP PLUMB ole
<br />l.EVEL
<br />
<br />1..11
<br />
<br />.
<br />
<br />
<br />r'f1 oE:':~::: f. ~j
<br />
<br />..' . . ~ P~E~CAST4 .. . "TtAT. POIJ~ >
<br />'. A^ CONCRETE SILL <) . . A^ CONCRETE SILl. <)
<br />v I I V ,
<br />SILL
<br />
<br />.
<br />
<br />. SEAUlNT BEAD
<br />
<br />I
<br />
<br />Ili'iSTALLATION DETAILS FOR :-.IO~.lMPACT, FLA.\lGE, HOR1L ROL-I
<br />LER Wl1\DOWS [:-I WI1\DZONES OF 150MPH OR LESS (per FBC 20(1)
<br />
<br />Buckstrips must be set in a bead of sealant. The exterior joint
<br />between the buckstrip and masonry must also be sealed.
<br />Buckstrips shall run the entire length of the rough opening. A
<br />buckstrip is not necessary at the sill if it is pre-cast. All gaps must
<br />be sealed. Buckstrips should be pressure treated yellow pine,
<br />spruce or comparable lumber, In accordance with the Florida
<br />Building Code, a taper, or bevel on the buck is acceptable if the
<br />window frame is fully supported by the buckstrip at both the
<br />interior and exterior.
<br />Ifusing 1" thick wood buckstrips:
<br />Installation fasteners should be a minimum f5" X 2t" masonry
<br />screws, installed through the window and buckstrip, into the
<br />masonry. Window may be shimmed as necessary, provided a
<br />minimum screw embedment of It" is maintained in the masonry.
<br />Fasteners sbould be located a maximum of 4" from each comer
<br />and maximum of 18" O.C. It is recommended that fasteners not be
<br />installed through the sill of the window. The actual size of the
<br />buckstrips should be no less than t" X 2*".
<br />rfusing 1~" thick or greater wood buckstrips (not sho\\u):
<br />Window installation fasteners should be a minimum #10 X I!"
<br />wood screws, installed through the window into the bucks trip.
<br />Window may be shimmed as necessary, provided a minimum
<br />screw embedment of It'' is maintained in the buckstrip. Window
<br />fasteners should be located a maximum of 4" from each comer and
<br />maximum of 18" O.C. It is recommended that fasteners oot be
<br />installed through the sill of the window. The actual size of the
<br />buckstrips should be no less than It" X 2i". Buckstrips should be
<br />installed using minimum f5" X 2i" masonry screws, to maintain
<br />1*" embedment, and be 18" O.C.
<br />
<br />THERMA-TRU INSTALLATION
<br />
<br />KEY DIFFERENCES CHECK LIST
<br />
<br />Rouqh openings o.re 1/4' sMo.ller on euch side und 114' sMo.ller on the
<br />heo.aer thun sto.ndo.rd TherMu- Tru rough opening diMensions,
<br />
<br />Use only 0. Mo.xiMUM of 1/4' thick shiMS,
<br />
<br />Predrill the jo.Mbs und heo.ders using 1/8' drill bit, Predrilling
<br />increo.ses structuro.l perf or Munce,
<br />
<br />Use only 2-1/2' wood screws (#8 o.nd #10) when securing the pre
<br />hung fruMe to the rough opening buck. Drywo.ll screws) deck screws)
<br />o.nd no.ils o.re insufficient o.nchors) o.nd should not be substituted for
<br />wood screws,
<br />
<br />Be certo.in of the nUMber o.nd plo.ceMent of o.ll screws securing the fro.Me
<br />to the rouq,h opening buck, Consult the o.rchitect or engineer of record
<br />concerning rusiening the buck to the rest of the building structure,
<br />
<br />CONTRACTOR TO PROVIDE A 1 x P,T, BUCK STRIP CONT, AT
<br />OPENING SIDES AND HEADER,
<br />
<br />** 1 x BUCK STRIPS ~ILL BE ACCEPTABLE PROVIDED THE
<br />3/16' DIA FLATHEAD TAPCONS ARE PROVIDED SPACED AS
<br />SHOYJN, THE T APCONS ARE TO BE CONTINUOUS THRU THE
<br />DOOR FRAME/. 1 x P,T, BUCK STRIP AND HAVE A MINIMUM
<br />OF 1 1/4' EMBEDMENT INTO THE MASONRY JAMBS,
<br />
<br />~' I # A 18 1ii1A1~, .c~~
<br />a l.. '.MIlT- l1A1=OClAT\ON
<br />
<br />Tampa, FL.(800) 282-6627.www.NUAirco: Mr.""">
<br />
<br />The window depicted in this drawing is intendcd for use on typical construction. It is the
<br />responsibility of others to detennine if it is applicable. Additional flashing, vapor barriers, etc.
<br />may be specified by the project architect. Wind and design pressures vary within each state and
<br />county. All products manufactured by NuAir loc. meet a minimum of 11 0 mph (R30 DP) wind
<br />load requirements (per AA.\1A 101); please check local building codes for exact requirements.
<br />
<br />SERIES 900 I
<br />PW & DPW
<br />
<br />--^ .I~OR
<br />~'V" .
<br />
<br />:'<l.~1
<br /><'. ."""
<br />>. ..,
<br />
<br />.....:~/
<br />. :.q." ....:;
<br />~~.
<br />- - vim:RloR
<br />
<br />I HEADER I
<br />~L1 . .<1'" .', ~
<br />l~ . . 4j
<br />I.~,// I
<br />EXTERIOR ~ ~ . INTI:RIOR
<br />· ' , , :'\ PRESSURE TREATED
<br />"~~ ,,,- "- BUCKSTRIP (MIN. 2$'
<br />" , AS SHOWN)
<br />---1
<br />SHIM AS NEEDED
<br />WINDOW
<br />fASTENER
<br />
<br />I
<br />
<br />r
<br />
<br />FU. INTI:RIOR VOID WI1H
<br />MINIMAL EXPANDING fOAM
<br />- IF PER CODE
<br />
<br />JAMBS
<br />
<br />IF NECESSARY,
<br />USE SHIMS
<br />WHEN
<br />INSTAWNG TO
<br />KEEP PLUMB &:
<br />l..EYE1..
<br />
<br />--J,Y
<br />
<br />/:1
<br />
<br />NO
<br />fASTENERS
<br />THROUGH ---1 r
<br />SILL J
<br />/ ~
<br />~~j
<br />
<br />~
<br />'=' I.
<br />,-- - - -
<br />r----
<br />(...,.: ."". ::. :.:
<br />
<br />~l
<br />
<br />'6
<br />. ~'<:1 6
<br />>. . . P~E-CAST >
<br />< '. 4^ CONCRETE SILL <
<br />v
<br />
<br />.(> .'
<br />
<br />. . 1v.T. pouRl:1) >
<br />A^ CONCRETE SILL <
<br />v
<br />
<br />. SEAUlNT BEAD
<br />
<br />SILL
<br />
<br />INSTALLAT10N DETAlLS FOR NO~-IMPACT, FLANGE, FIXED
<br />WINDOWS IN WI~DlONES OF IS0MPH OR LESS (per FBC 2001)
<br />
<br />I
<br />
<br />Buckstrips must be set in a bead of sealant. The exterior joint
<br />between the buckstrip and masonry must also be sealed.
<br />Buckstrips shall run the entire length of the rough opening. A
<br />buckstrip is not necessary at the sill ifit is pre-cast. All gaps must
<br />be sealed. Buckstrips should be pressure treated yellow pine,
<br />spruce or comparable lumber. In accordance with the Florida
<br />Building Code, a taper, or bevel on the buck is acceptable if the
<br />window frame is fully supported by tbe buckstrip at both the
<br />interior and exterior.
<br />
<br />[f using l" thick wood bucks trips:
<br />Installation fasteners should be a minimum Jt, X 2t" masonry
<br />screws, installed through the window and buckstrip, into the
<br />masonry. Window may be shimmed as necessary, provided a
<br />
<br />minimum screw embedment of It" is maintained in the masonry.
<br />Fasteners should be located a maximum of 4" from each comer
<br />and maximum of 18" O.C. The actual size of the buckstrips should
<br />
<br />be no less than l" X 2k".
<br />
<br />[fusing It" thick or greater wood buckstrips (not sho\\-n):
<br />Window installation fasteners should be a minimum # 10 X I!"
<br />wood screws, installed through the window into the buckstrip.
<br />Window may be shimmed as necessary, providcd a minimum
<br />
<br />screw embedment of 1*" is maintained in the buckstrip. Window
<br />fasteners should be located a maximum of 4" from each comer and
<br />maximum of 18" O.c. The actual size of the bucks trips should be
<br />
<br />no less than I!" X ;ts.'. Buckstrips should be installed using
<br />minimum Jt. X 2t" masonry screws, to maintain
<br />d" embedment, and be 18" O.C.
<br />
<br />e' ,
<br />~t- r
<br />
<br />
<br />,
<br />
<br />tf' ,
<br />4 3'
<br />
<br />
<br />
<br />
<br />
<br />, 6
<br />
<br />6' 6'
<br />
<br />I I
<br />
<br />I I
<br />
<br />SPACE
<br />EVENL Y
<br />
<br />
<br />
<br />
<br />6' 6'
<br />
<br />6'
<br />
<br />I I I I I I I I I I 6'
<br />
<br />
<br />lir~tf1rrm !~
<br />
<br />SINGLE DOOR
<br />
<br />SINGLE DOOR ~ I SIDELITES
<br />
<br />SINGLE DOOR VI SIDELITE
<br />
<br />'j'~!4AR [j)~~~
<br />, ~ ....SSOClAnON
<br />. MEMBEJl
<br />Tampa, FL .(800) 282-6627.www.NuAircom
<br />
<br />The window depicted in this drawing is intended for use on typical construction. [t is the
<br />responsibility of others to determine if it is applicable. Additional tlashing, vapor barriers, etc.
<br />may be specified by the project architect. Wind and design pressures vary within each state and
<br />county. All products manufactured by NuAir Inc. meet a minimum of 110 mph (R30 DP) wind
<br />load requirements (per AA.\1A 10 l); please check local building codes for exact requirements.
<br />
<br />SERIES 200 I
<br />HEADER & 500 SOD
<br />A ^
<br />
<br />W/d~~~~~
<br />./ / /h~ IJ J / / '/
<br />
<br />EXTt:RIOR
<br />INTERIOR PRESSURE
<br />~-~~
<br /><~~ / ~ER
<br />/j//
<br />~~ ~..
<br />~~ ...
<br />~~-
<br />~ .. AfTER
<br />< ~ INSTAl.u.OON. SEAL
<br />JAMBS ~~r\
<br />
<br />~ AND JAMB 1,1 \-W
<br />EXTt:RIOR --e-
<br />"
<br />
<br />INTI:RIOR
<br />
<br />.
<br />
<br />'-I ~
<br />
<br />PII
<br />- ~
<br />
<br />SHIM
<br />I>S
<br />NEEDED
<br />
<br />......-L.
<br />'""""'T
<br />
<br />l
<br />1
<br />
<br />,
<br />.@ :;. ~ :"
<br />,
<br />
<br />-~:
<br />
<br />,
<br />
<br />'i;
<br />
<br />,
<br />
<br />MiNIMUM
<br />1~'
<br />REcOM-
<br />MOlDED
<br />
<br />..
<br />
<br />H
<br />
<br />H
<br />
<br />w
<br />c
<br />
<br />. ~
<br />,<>
<br /><l
<br />
<br />flLL INTI:RIOR VOID W1ll-t
<br />MiNIMAL EXPANDING fOAM
<br />- IF PER CODE
<br />
<br />A
<br />IF NECESSARY,
<br />. 4 USE SHIMS WHEN
<br />. . INSTAlliNG TO _.1
<br />. KEEP PLUMB ole~
<br />. -
<br />TRACK
<br />
<br />~ 4:
<br />
<br />. SEALANT BEAD
<br />
<br />- L...t\ .
<br />v
<br />
<br />ilIiST ALLA nON DETAILS FOR NON-L\tP ACT, SLlDlNG GLASS
<br />DOORS 1:--1 WINDlONES OF 150MPH OR LESS (per FBC 20(1)
<br />
<br />Buckstrips must be set in a bead of sealant. The exterior joint
<br />between the bucks trip and masonry must also be sealed.
<br />Buckstrips shall run the entire length of the rough opening,
<br />except door sill. All gaps must be sealed. Buckstrips should be
<br />pressure treated yellow pine, spruce or comparable lumber. In
<br />accordance with the Florida Building Code, a taper, or bevel
<br />on tbe buck is acceptable if the door frame is fully supported
<br />by the buckstrip at both the interior and exterior.
<br />
<br />I
<br />
<br />
<br />
<br />
<br />6'
<br />
<br />
<br />,
<br />
<br />SPACE
<br />EVENL Y
<br />
<br />[fusingt" thick wood buckstrips:
<br />Installation fasteners should be a minimum f5" X 2t" masonry
<br />screws, installed through the door frame and buckstrip, into the
<br />masonry. Door may be shimmed as necessary, provided a
<br />minimum screw embedment of It'' is maintained in the
<br />masonry. Fasteners should be located a maximum of 4" from
<br />each comer and maximum of 18" O.C. The width of the
<br />buckstrips should be no less than the frame frame of the door.
<br />
<br />Ifusing 1~" thick or greater wood buckstrips (not shown):
<br />Door installation fasteners should be a minimum #10 X It"
<br />wood screws, installed through the window into the buckstrip.
<br />Door may be shimmed as necessary, provided a minimum
<br />screw embedment of It" is maintained in the buckstrip. Door
<br />fasteners should be located a maximum of 4" from each corner
<br />and maximum of 18" O.C. The width of the buckstrips should
<br />be no less than the frame frame of the door. Buckstrips should
<br />be installed using minimum f5" X 2i" masonry screws, to
<br />maintain 1t" embedment, and be 18" O.C.
<br />
<br />DOUBLE DOOR ~ I SIDELITES
<br />
<br />DOUBLE DOOR
<br />
<br />~ '~WR lI1,"",.RJCAN
<br />ARCHJTECiLRAl.
<br />MANUFAcrt.'1U;S
<br />! ASSOCLArlON
<br />a . \frMllJ:Jl
<br />
<br />Tampa, FL.(800) 282-6627-www.NuAircom
<br />
<br />The door depicted in this drawing is intended for use on typical construction. It is the
<br />responsibility of others to determine if it is applicable. Additional !lashing, vapor barriers, etc.
<br />may be specified by the project architect. Wind and design pressures vary within each state and
<br />county. All products manufactured by NuAir Inc. meet a minimum of liD mph (R30 DP) wind
<br />load requirements (per AA.\1A 101); please check local building codes for exact requirements.
<br />
<br />SERIES 200 I
<br />& 500 SOD
<br />
<br />HEADER
<br />^
<br />
<br />Y/~ @; ~
<br />
<br />INTI:RIOR
<br />
<br />.
<br />
<br />. INTI:RIOR
<br />SHIM
<br />AS
<br />NEEDED
<br />
<br />A
<br />~/.
<br />~ /~'"
<br /><~ -1
<br />~ .- J::S
<br />
<br />/',./ . - AfTER
<br />~ ~ INSTAl.u.nON, SEAL
<br />HORIZONTAL JOINT~
<br />EXTtRIOR BETWEEN TRACK
<br />AND JAMB
<br />.
<br />,
<br />
<br />flLL INTI:RIOR VOID Wffit t.. V"
<br />MINIMAL EXPANDING fOAM ...
<br />- IF PER CODE
<br />
<br />. SEALANT BEAD
<br />
<br />PI
<br />
<br />..
<br />~
<br />
<br />..
<br />-
<br />
<br />'-"
<br />
<br />1i::...Ii : J.
<br />"", ~ I
<br />:' :
<br />': -^v--. '
<br />-, I
<br />" ,
<br />I ,
<br />::~ ~ ia-
<br />
<br />.:
<br />
<br />MIN:MUM
<br />1i"
<br />RECOM-
<br />MENDED
<br />
<br />H
<br />
<br />~
<br />
<br />~
<br />
<br />.<>
<br /><::
<br />1~1EC~,
<br />USE SHIMS WHEN
<br />INSTAlliNG TO . A
<br />. KEEP PLUMB &. LEYEL"
<br />. 1\ L-
<br />TRACK
<br />
<br />..6
<br />
<br />ilIiST ALLA nON DETAILS FOR NON-L\tPACT, SLlDlNG GLASS
<br />DOORS I~ WINDlONES OF 150MPH OR LESS (per FBC 2001)
<br />
<br />I
<br />
<br />Sliding Glass Door Installation:
<br />
<br />[nstallation fasteners for jambs and
<br />header should be a minimum #10 x It" screw.
<br />Installation fasteners for the track should be a
<br />minimum It" masonry screw. All fasteners should
<br />have an embedment of at least It". Fasteners
<br />should be located at a maximum of 4" from each
<br />corner and 18" O.C. for screws.
<br />It is recommended that all screws be
<br />sealed to prevent infiltration of air and water.
<br />Product may be shimmed up to t" if necessary.
<br />
<br />& CREATED 01-02-02
<br />
<br />120
<br />SEC.
<br />
<br />MPH
<br />GUST
<br />
<br />3
<br />
<br />Weatherprooting:
<br />
<br />D E DAN5CO
<br />
<br />ENGINEERING, FA.
<br />p.o. eox 3400 - APOL.L.O ee~ - FL.ORIDA - 33&12
<br />~ - (8t3) 646 0166 FAX - (813) 646 ~ca8
<br />E6 ...at"" iC\ 11-IESE DRA'MNGS AND DESIGNS ARE TI-lE JOINT PRQP[RTY Of DANSCO ENGINEERING. PA. AND 11-IE
<br />"'tQ IV ~ ClIENT ON 11-IIS PRO-ECT. ANY REPROOUCTlON OR UNAU11-IORIZED USE IS PROHIBITED - 2003
<br />
<br />Flexible flashing should be installed in a
<br />weatherboard fashion. The top layer should overlay
<br />any layer beneath it. The weather resistant barrier
<br />should then cover the flexible flashing at the
<br />header.
<br />The application of the weather resistant
<br />barrier will vary based on when it is installed. Ifit
<br />is installed after the door, it should be tucked under
<br />the sill flashing and overlap the jambs and head
<br />flashing.
<br />
<br />LENNAR t40MES
<br />
<br />ecALE NOTED
<br />DATE 01/02
<br />
<br />DRAU.N B.Y.
<br />
<br />TAMPA DIVl810N
<br />
<br />'j'~!4AR [j)~=~
<br />, ~ .....SSOCIA nON
<br />. MEMBER
<br />
<br />Tampa, FL .(800) 282-6627-www.NuAircom
<br />
<br />The door depicted in this drawing is intended for use on typical construction. It is the
<br />responsibility of others to determine if it is applicable. Additional !lashing, vapor barriers, etc.
<br />may be specified by the project architect. Wind and design pressures vary within each state and
<br />county. All products manufactured by NuAir Inc. meet a minimum of 110 mph (R30 DP) wind
<br />load requirements (per AA.\1A 101); please check local building codes for exact requirements.
<br />
<br />DOOR 4 WINDOW INSTALLATIONS
<br />
<br />DE Joe NO. Ft1 - &021
<br />
<br />8DW2-N
<br />
|