My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
07-7149
Zephyrhills
>
Building Department
>
Permits
>
2007
>
07-7149
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:32:40 PM
Creation date
8/6/2008 8:03:20 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-7149
Building Department - Name
SOWA,JOHN
Address
39020 9TH AV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />.; <br /> <br /> <br />OFFICIAL TEST RESULTS <br /> <br />. Paragrapb Number Title of Test <br />2.1.7 Comer Weld Test: <br />Frame comer <br />Vent comer <br /> <br />Measured <br /> <br />95 pounds (422 N) <br />50 pounds (222 N) <br /> <br />Note; The break did not extend along entire weld line. <br /> <br />2.1.8 Forced Entry Resistance Test: <br />AAMA 1303.5-1976, Paragraph <br />3.1.1 Test A through 3.1.5 Test G <br /> <br />No entry <br /> <br />2.2.1.5.1 <br />Starting Force: <br />Operating Force: <br /> <br />10 pounds (44 N) <br />13 pounds (57 N) <br /> <br />2.2.1.5.2 Deglazing Test: (ASTM E98?-88) <br />No ~ement at <br />Horizontal Rails <br />Vertical Rails <br />Percent Deglazement <br /> <br />SO pounds (222 N) <br />70 pounds (311 N) <br />S percent <br /> <br />SECTION 4. OPTIONAL PERFORMANCE CLASS: <br /> <br />4.3 <br /> <br />Water Resistance Test (ASTM ES47-961E331) <br />no leakage at <br /> <br />9.00psf(430Pa) <br /> <br />4.4.2 Unifonn Structural Load Test: (ASTM E330-96) <br />Positive Load 90.0 psf (4309 Pa) <br />Deflcctlon Permaaot Set <br />Reading at meeting rail 2.803" (71.28mm) 0.072" (1.83mm) <br />Reading at frame jamb 0.240" (6.JOmm) 0.005" (0. 13mm) <br />Readin2 at frame sill 0.390" (9.92mm) 0_015" (0.38mm) <br /> <br />4.42. Unifonn Structural Load Test: (ASTM E330-96) <br />Negative Load 97.5 psf (4668 Pal <br />Reading at meeting rail 3.280" (83.4hnm) 0.113" (2.87mm) <br />Reading at frame jamb 0.363" (9.23mm) 0.020" (0.5 lmm) <br />Reading at frame sill 0.485" (12.33mm) 0.026" (0.66mm) <br /> <br />Lab. Number 4551 <br />March 30, 2005 <br />Report Number 11 <br />File Numbel 05-116 <br />Page 3 of 4 <br />0-6985 <br /> <br />Allowed <br />Passed <br /> <br />Passed <br /> <br />None Allowed <br /> <br />25 (111) maximum <br />25 (Ill) maximum <br /> <br />Passed <br /> <br />SO (222) minimum <br />70 (311) minimwn <br />99 maximum <br /> <br />Passed <br />5.25 (251) minimum <br /> <br />Passed <br />52.5 (2514) minimum <br /> <br />0.233 (5.92) maximum <br /> <br />Passed <br />52.5 (2514) minimum <br />0233 (5.92) maximum <br /> <br />Note: At conclusion of above tests, there was no apparent damage to unit, glass or fasteners and the vents were <br />operable. <br /> <br />Temperature: 67.0 F <br />Barometer Reading: 29.95 <br /> <br />Testing Began - February 24, 2UU5 <br />Test Completed - February 24, 200S <br />Report Expires - February 24, 2009 <br /> <br />t!:!.~ <br />
The URL can be used to link to this page
Your browser does not support the video tag.