My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-7404
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-7404
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:31:45 PM
Creation date
8/13/2008 8:58:23 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
08-7404
Building Department - Name
NESTLE WATERS NA, INC
Address
4330 20TH STREET
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br />..:s,..: -.- <br /> <br /> <br />The AUTOPULSE'! 542R is a six zone FACP lor single and dual hazard <br />agent releasing applications. The AUTOPULSE 542R provides reliable <br />lire detection, signaling and protection lor commercial, industrial and <br />institutional buildings requiring agent-based releasing. The AUTOPULSE <br />542R is compatible with System Sensor's i3 detectors which are <br />conventional smoke detectors that can transmit a maintenance trouble <br />signal to the FACP indicating the need for cleaning and a superviSOry <br />'freeze' signal when the ambient temperature falls below the detector <br />rating of approximately 45 of (7.22 OC), In addition, the control panel is <br />compatible with conventional input devices such as two-wire smoke <br />detectors, four-wire smoke detectors, pull stations, waterflow devices, <br />tamper switches and other normally-open contact devices. Refer to <br />Device Compatibility Document for a complete listing of compatible <br />devicQs." <br /> <br />Four outputs are programmable as NACs (Notification Appliance <br />Circuits) or releasing circuits. Three programmable Form-C relays <br />(factory programmed for Alarm, Trouble and SuperviSOry) and 24 VDC <br />special application resettable and non-resettable power outputs are also <br />included on the main circuit board. The AUTOPULSE 542R supervises <br />all wiring, AC voltage, battery charger and battery level. <br /> <br />Activation of a compatible smoke detector or any normally open fire <br />alarm initiating device will activate audible and visual signaling devices, <br />illuminate an indicator, display alarm information on the panel's LCD, <br />sound the piezo sounder at the FACP, activate the FACP alarm relay <br />and operate an optional module used to notify a remote station or initiate <br />an auxiliary controllunction. . <br /> <br />The AUTOPULSE 542R(E) releasing panel offers the same features as <br />the AUTOPULSE 542R but allows connection to 220/240 VAC, Unless <br />otherwise specified, the information in this data sheet applies to both the <br />110/120 VAC and 220/240 VAC versions of the panels, <br /> <br />", <br /> <br /> <br />. Designed for agent releasing standards NFPA 12, 12A, 12B and 2001 <br />. Disable/Enable control per input zone and output zone <br />. Extensive transient protection <br />. Dual hazard operation <br />. Adjustable pre-discharge, discharge and waterflow delay timers <br />. Cross-zone (double-intertock) capability <br />. Six programmable Style B (Class B) iDCs (Initiating Device Circuit) <br />. System Sensor 13 series detector compatible <br />. Four programmable Style Y (Class B) output circuits - (special appli- <br />cation power) <br />. Strobe synchronization <br />- System Sensor <br />- Wheelock <br />- Gentex <br />- Faraday <br />- Amseco <br />. Three programmable Form-C relays <br />. 7,0 amps total 24 VDC output current <br />. Resettable and non-resettable output power <br />. Built-in Programmer <br />. Short circuit RAC supervision <br /> <br /> <br />00,.,.11 <br /> <br />. ANN-BUS for connection to optional (up to eighttOlal of any of the <br />following): <br />- N-ANN-80 Remote LCD Annunciator <br />- N-ANN-I/O LED Driver <br />- N-ANN-S/PG Printer Module <br />- N-ANN-RL Y Relay Module <br />_ N-ANN-LED Annunciator Module <br />. 80-character LCD display (backlit) <br />. Real-time clock/calendar with daylight savings time control <br />. History log with 256 event storage <br />. Piezo sounder for alarm, trouble and supervisory <br />. 24 volt operation <br />. Low AC voltage sense <br />. Outputs programmable for: <br />- Releasing Circuits <br />. NACs programmable for: <br />- Silence Inhibit <br />- Auto-Silence <br />- Strobe Synchronization <br />_ Selective Silence (horn-strobe mute) <br />- Temporal or Steady Signal <br />- SilenceabJe or Non-silenceable <br />- Release Stage Sounder <br />. Automatic battery charger with charger supervision <br />. Optional Dress Panel DP-510SO (red) <br />. Optional Trim Ring TR-CE (red) lor semi-flush mounting the cabinet <br />. Optional CAC-5X Class A Converter Module for Outputs and IDCs <br />. Optional 4XTM Municipal Box Transmitter Module <br />. Optional Digital Alarm Communicators (411, 411UD, 411UDAC) <br />
The URL can be used to link to this page
Your browser does not support the video tag.