Laserfiche WebLink
<br />- :>.; <br /> <br /> <br />PROGRAMMING AND SOFTWARE: <br /> <br />. Custom English labels (per point) may be manually entered or <br />selected from an intemallibrary file <br /> <br />. Programmable Abort operation <br /> <br />. Three programmable Form-C relay outputs <br /> <br />. Pre-programmed and custom application templates <br /> <br />.. Continuous fire protection during online programming at the front <br />panel <br /> <br />. Program Check automatically catches common errors not linked to <br />any zone or input point <br /> <br />USER INTERFACE: <br />. Integral 80-character LCD display with backlighting. <br />. Real-time clock/calendar with automatic daylight savings adjustments. <br />. ANN-Bus for connection to remote annunciators. <br />. Audible or silent walk test capabilities. <br />. Piezo sounder for alann, trouble, and supervisory. <br /> <br />CON11lOL5 AND INDICATORS <br /> <br />LED INDICATORS <br />. FIRE ALARM (red) <br />. SUPERVISORY (yellow) <br />. TROUBLE (yellow) <br />. AC POWER (green) <br />. ALARM SILENCED (yellow) <br />. DISCHARGED (red) <br />. PRE-DISCHARGE (red indicator) <br />. ABORT{yellow indicator) <br /> <br />CONTROL BUTTONS <br />. ACKNOWLEDGE <br />. ALARM SILENCE <br />. SYSTEM RESET (tamp test) <br />. DRILL <br /> <br />AC Power-TB1 <br />. AUTOPULSE 542R: 120 VAC. 50/60 Hz, 2.3 amps <br />. AUTOPULSE S42R{E): 240 VAC, 50 Hz, 1.15 amps <br />. Wire size: minimum #14 AWG (2,O mm2) with 600V insulation <br />. Supervised, nonpower-Iimited <br /> <br />Battery (sealed lead acid only) - J12: <br /> <br />. Maximum Charging Circuit - Normal Flat Charge: 27.6 VDC @ <br />1.4 amp Supervised. nonpower-limited <br /> <br />. Maximum Charger Capacity: 26 Amp Hour battery (two 18 Amp <br />Hour batteries can be housed in the FACP cabinet. Larger batteries <br />require separate battery box such as the BB-26 or BB-55). <br /> <br />. Minimum Battery Size: 7 Amp Hour <br /> <br />Initiating Device Circuits - 104 ana I 00 <br />. Alann Zones 1 - 5 on TB4 <br />. Alarm Zone 6 on TB6 <br />. Supervised and power-limited circuitry <br />. Style B (Class B) or Style Z (Class A) with optional converter module <br />. Normal Operating Voltage: Nominal 20 VDC <br />. Alarm Current: 15 mA minimum <br />. Short Circuit Current: 40 mA maximum <br />. Maximum Loop Resistance: 100 Ohms <br />. End-of-Llne Resistor: 4.7K Ohms. 1/2 watt (Part No. 71252) <br />. Standby Current: 4 mA <br /> <br />Notification Applance and Releasing Clrcult(s) - TBS and TB7 <br />. Four output circuits <br />. Style Y (Class B) or Style Z (Class A) with optional converter module <br />. Special application power <br />. Supervised and power-limited circuitry <br />. Normal Operating Voltage: Nominal 24 VDC <br />. Maximum Signaling Current: 7.0 amps (3.0 amps maximum per <br />NAC) <br />. End-of-L1ne Resistor: 4.7K Ohms. 1/2 watt (Part No. 71252) <br />. Maximum Wiring Voltage Drop: 2 VDC <br />Refer to the Device Compatibility Document for compatible listed <br />devices. <br /> <br />Form-C Relays - Programmable - TB8 <br /> <br />. Relay 1 (factory default programmed as Alarm Relay) <br />. Relay 2 (factory default programmed as fail-safe Trouble Relay) <br />. Relay 3 (factory default programmed as Supervisory Relay) <br />. Relay Contact Ratings: <br />- 2 amps @ 30 VDC (resistive) <br />- 2 amps @ 30 VAC (resistive) <br /> <br />Auxiliary Trouble Input - J6 <br /> <br />The Auxiliary Trouble Input is an open collector circuit which can be <br />used to monitor external devices for trouble conditions. It can be <br />connected to the trouble bus of a peripheral, such as a power supply, <br />which is compatible with open collector circuits, <br /> <br />Special Application Resettable Power - TB9 <br /> <br />. Operating Voltage: Nominal 24 VDC <br /> <br />. Maximum Available Current: 500 mA - appropriate for powering <br />4-wire smoke detectors (see Note 1) <br /> <br />. Power-limited circuitry <br /> <br />Note 1: Total current for resettable power, nonresettable power and <br />output circuits must not exceed 7.0 amps. <br /> <br />Special Application Resettable or Nonresettable Power - TB9 <br />. Operating Voltage: Nominal 24 VDC <br />. Maximum Available Current: 500 mA (see Note 1) <br />. Power-limited circuitry <br />. Jumper selectable by JP31 for resettable or nonresettable power <br />