07-7336
Zephyrhills
>
Building Department
>
Permits
>
2007
>
07-7336
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:49:52 PM
Creation date
9/19/2008 10:34:47 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-7336
Building Department - Name
ZEPHYR LLC
Address
5931 GALL BV
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
9
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Zephyrhills Fire Rescue <br />6907 Dairy Road, Zephyrhills, FL 33542 <br /> <br />F ire Marshal <br />Kerry Barnett <br /> <br />Bus (813) 780-0041 <br />Fax (813) 780-0044 <br /> <br />December 17, 2007 <br /> <br />Plan Review Comments <br /> <br />I have reviewed and approved the revision for an interior remodel located at 5931 Gall <br />Blvd. under the following conditions. My comments have been placed below. Please <br />contact me if you have any questions with regards to my comments. <br /> <br />1. Add additional emergency light in corridor entering handicapped restrooms. This <br />light can be back to back with light in women's restroom. <br />2. Add smoke detectors tied into fire alarm system in handicap restroom corridor <br />and corridor entering restrooms. <br />3. Add strobes tied into fire alarm system in all restrooms. Add audible devices <br />where necessary ( corridors). <br />4. Add exit light in conference room for direction of egress from conference room. <br />5. Add horn/strobe device in conference room tied into alarm system. <br />6. If there is a direct exit to outside from conference room, fire alarm pull station <br />required. <br />7. Certified fire extinguishers shall be properly located within 75' travel distance. <br />8. Sprinkler system, if applicable, shall have plans submitted for modification. <br />9. Fire alarm system addition requires permit and plans for scope of work, specs <br />details and battery cales. This is necessary to ensure devices are compatible with <br />current system. <br /> <br />Inspections required: <br /> <br />1. Building final. <br />2. Additional inspections will be required due to fire alarm and if necessary, the <br />sprinkler system. <br /> <br />Note: If no current sprinkler system, sprinkler system not required at this time <br />because remodeled area is less than the required percentage of an existing 5000 sq It <br />building. Additional future remodeling could require the building to retrofit for a <br />sprinkler system. <br />