Laserfiche WebLink
<br />TENT/VENDOR CHECKLIST <br /> <br />The AHJ shall be permitted to regulate all outdoor events such as carnivals and fairs as it <br />pertains to access for emergency vehicles; access to fire protection equipment; placement <br />of stands, concession booths, and exhibits; and the control of hazardous conditions <br />dangerous to life and property. NFPA 1, Section 10,16.2 <br /> <br />Event coordinator(s) shall provide the vendors a checklist of what is expected of them at <br />the event. However, individual vendors within the special event shall be held responsible <br />for their individual vending space. Those that do not comply with the guidelines of this <br />checklist for their vending arrangement are subject to immediate denial within <br />participation of the permitted event. <br /> <br />Plot Plan showing setup. If part of an overall event, this shall be supplied <br />by the event coordinator. <br />Notarized letter from property owner stating their approval. <br />Proof of liability insurance. <br />If tent is greater than 10 x 10, flame retardant certification is required. If <br />multiple lOx 10 tents are placed together to create one large space under <br />canopy, than a flame retardant certification shall be required on all tents, <br />No smoking signs must be placed outside entrances. <br />If there is to be wire fencing or chain link: fencing, this fence shall be set <br />back from the tent at least 5 feet and have at least 2 exits. <br />If tent has sides, the sides shall be in the up position unless there is <br />inclement weather, than 2 sides must be in the up position. <br />Adjacent tents shall be spaced a minimum of five (5) feet to provide an <br />area to be used as a means of emergency egress. If stake lines are used to <br />secure the tent, than the five (5) feet shall be measured from the stake line, <br />The ground enclosed by any tent and ground not less than 120" outside the <br />tent shall be cleared of all flammable or combustible material or <br />vegetation that is not used for necessary support equipment. <br />If lighting is installed in tent, it shall be in the way that bulbs are not in <br />direct contact with the tent. Bulb/lamp cages shall be used. <br />If power is supplied by generator, generator shall be a minimum of 5 feet <br />from the tent and shall be isolated from contact with the public by either <br />physical guards, fencing, or an enclosure, Fuel containers shall not be <br />stored within close proximity of any ignition source. <br />Any extension cords used shall be placed or positioned to not cause a <br />trip/fall hazard. <br />A minimum of one portable fire extinguisher with a rating of not less than <br />2-A: 1 O-B:C shall be provided if there is any type of ignition source present <br />within or associated with the tent. (See note at bottom) <br />If an LP (propane) tank is used by the vendor it shall be positioned outside <br />the footprint of the tent. <br />