Laserfiche WebLink
<br />. <br />Chasey Lane Townhomcs, LLC <br />Chasey Lane Townhomes <br />P A File No. CS51-0030492-055 <br />, <br /> <br />SPEClFIC CONDITIONS CONTINUED: <br />6. All collection/transmission systems shall be constructed using the pipe diameters designated in the <br />drawings and specifications included with the permit application for this project and approved by the <br />Department. Pursuant to Section 33.43 of the "Recommended Standards Jor Wastewater Facilities," <br />1990 ed. (incorporated into Chapter 62-604 of the Florida Administrative Code by reference), <br />oversize sewers shall not be approved to justify using flatter slopes. <br /> <br />7. If historical or archaeological artifacts, such as Indian canoes, are discovered at any time within the <br />project site, the permittee shall immediately notify the DEP Southwest District office and the Bureau <br />of Historic Preservation, Division of Archives, History and Records Management, R.A. Gray <br />Building, Tallahassee, Florida 32301, telephone number (904) 487-2073. <br /> <br />8. All components of the lift station, i.e. the wetwell, valve ~ox, and electrical control panel will be <br />locked or otherwise secured against unauthorized access. <br /> <br />9. Upon completion of construction and prior to placing the system into use, the perrrlittee or his <br />engineer-of-record shall submit to this Department the following documents: <br /> <br />(a) Domestic Wastewater CollectionlTransmission Systems Certification of Completion of <br />Construction [DEP Form 62-604.300(7)(b)], together with a copy of the record drawings for the <br />system; and <br /> <br />(b) Certification by the Professional Engineer-of-Record shall be construed to mean conformance to <br />the General Technical Guidance for Collection Systems and Transmission Facilities [62-604, <br />F.A.C.], particularly the pertinent sections of the Recommended Standards for Sewage Works and <br />also WPCF MOP9. <br /> <br />Department acceptance and written approval of these documents shall be required prior to placing the <br />system into service. <br /> <br />10. The system shall be inspected for any sediment debris and flushec1 - . . to connection to the <br />designated WWTP. <br /> <br />11. The permittee shall be aware of and operate under the attached "General Permit Conditions #1 <br />through #15". General Permit Conditions are binding upon the permittee and enforceable pursuant to <br />Chapter 403 of the Florida Statutes. <br /> <br />r#- <br /> <br /> <br />Jef S. Gree well, P.E. <br />Wa er Facilities Administrator <br />Southwest District <br />3804 Coconut Palm Drive <br />Tampa, FL 33619-1352 <br /> <br />Page 2 of2 <br />