<br />Zephyrhills Fire Rescue <br />6907 Dairy Road, Zephyrhills, FL 33542 <br /> <br />F ire Marshal <br />Kerry Barnett <br /> <br />Bus (813) 780-0041 <br />Fax (813) 780-0044 <br /> <br />November 21, 2007 <br /> <br />I have reviewed and approved the plans for construction for the addition to Nestle Waters <br />(Zephyrhills Plant) located at 4330 20th Street. I have attached the comments for the plan <br />approval. If there are any questions please contact my office at 813-780-0041. <br /> <br />1. Per previous meetings, south entrance road shall have hydrants installed at <br />500' intervals. <br />2. Per NFP AI, fire safety practices shall be in place during construction. <br />3. Per previous meetings, knox key switch required on all access gates. Knox <br />boxes will also be required at locations to be determined later by Fire Marshal. <br />These locations will be different access points in to the building. Application <br />supplied. <br />4. Fire rated doors installed in 2 hour wall shall be a rating of 1 ~ hours. Pump <br />room door shall also be rated to a 45 minute rating for a 1 hour separation. <br />5. Install additional exit lighting in EIW corridors at each intersection leading to <br />exterior exit. Exit signs provide additional directions to where these egress <br />points are located. Install additional exit sign at west door north of pump <br />room. <br />6. Paint lines on floor showing locations of egress where no storage is to be <br />located. Same as existing building. <br />7. Separate fire alarm plans are required to be submitted for permit. <br />8. Separate sprinkler plans are required to be submitted for permit. As of this <br />time, already received documentation that current fire pump is capable of <br />performing within guidelines with the addition to the sprinkler system. Advise <br />contractor that FDC connections will need to be placarded in reflective <br />background so that these can easily be located in darkness. <br />9. Emergency escape plans shall be placed throughout building showing <br />direction of egress travel to nearest exit. <br />10. Separate plans shall be required for relocation of propane. Permit required. <br />Specs/details required for plan submittal shall be tank information, piping, <br />emergency shutoffs, protection in place, etc... <br />11. All penetrations in any fire separations, end of sleeves shall be filled with <br />minimum W' fire rated caulk. <br />12. Emergency shunt for electric required outside the building. Shunt shall be <br />placarded same as FDC's so it is easily read in darkness. <br />