Laserfiche WebLink
<br />@ PQ!!!Jition <br /> <br />VSR-F <br />VANE TYPE WATERFLOW <br />ALARM SWITCH WITH RETARD <br /> <br /> <br />U.S. Pat. No. 3921989 <br />Canadian Pat. No. 1009680 <br />Other Patents Pending <br />Potter Electric, Rd., 1990 <br /> <br />UL, ULCandCSFMListed, FMandLPCBApproved,NYMEA <br />Accepted, CE Marked <br /> <br />Service Pressure: Up to 450 PSI (31 BAR) <br /> <br />Minimum Flow Rate for Alarm: 10 GPM (38 LPM) <br /> <br />Maximum Surge: 18 FPS (5,5 m/s) <br /> <br />Contact Ratings: Two sets of SPDT (Form C) <br />15.0Amps at 125/250VAC <br />2.0 Amps at 30VDC Resistive <br /> <br />Conduit Entrances: Two knockouts provided for 1/2" conduit <br /> <br />Environmental Specifications: <br />. Suitable for indoor or outdoor use with factory installed <br />gasket and die-cast housing. <br />. NEMA 4/IP54 Rated Enclosure - use with appropriate <br />conduit fitting. <br />. Temperature Range: 40oF/120oF, 4,50C/490C <br />. Non-corrosive sleeve factory installed in saddle. <br /> <br />Caution: This device is not intended for applications in explosive <br />environments. <br /> <br />Sizes Available: Steel Pipe schedules 1 0 thru 40, sizes 2" thru 8" <br />BS 1387 pipe 50mm thru 200mm <br />Note: For copper or plastic pipe use Model VSR-CF. <br /> <br />Service Use: <br />Automatic Sprinkler NFPA-13 <br />One or two family dwelling NFPA-13D <br />Residential occupancy up to four stories NFPA-13R' <br />National Fire Alarm Code NFPA-72 <br /> <br />Optional: Cover Tamper Switch Kit, Stock No. 0090018 <br /> <br />GENERAL INFORMATION <br /> <br />The Model VSR-F is a vane type waterflow switch for use on <br />wet sprinkler systems. It is UL Listed and FM Approved for <br />use on steel pipe; schedules 10 through 40, sizes 2" thru 8" <br />(50mm thru 200mm). <br /> <br />LPC approved sizes are 2" thru 8" (50mm thru 200mm). <br /> <br />The unit may also be used as a sectional waterflow detector <br />on large systems. <br /> <br />The unit contains two single pole, double throw, snap action <br />switches and an adjustable, instantly recycling pneumatic re- <br />tard. The switches are actuated when a flow of 10 gallons per <br />minute (38 LPM) or more occurs downstream of the device, <br />The flow condition must exist for a period of time necessary to <br />overcome the selected retard period. <br /> <br />ENCLOSURE: The unit is enclosed in a general purpose, die- <br />cast housing. The cover is held in place with two tamper resis- <br />tant screws which require a special key for removal. A field in- <br />stallable cover tamper switch is available as an option which <br />may be used to indicate unauthorized removal of the cover. See <br />bulletin no. 5400775 for installation instructions of this switch, <br /> <br />INSTALLATION: See Fig.2 <br /> <br />These devices may be mounted on horizontal or vertical pipe. <br />On horizontal pipe they should be installed on the top side of the <br />pipe where they will be accessible, The units should not be in- <br />stalled within 6" (15cm) of a fitting which changes the direction of <br />the waterflow or within 24" (60 cm) of a valve or drain. <br /> <br />Drain the system and drill a hole in the pipe using a circular saw <br />in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices <br />require a hole with a diameter of 1 1/4" + 1/8" - 1/16" (33mm <br />:t2mm). All other sizes require a hole with a diameter of 2" :1:1/8" <br />(50mm :t2mm). <br /> <br />Clean the inside pipe of all growth or other material for a dis- <br />tance equal to the pipe diameter on either side of the hole. <br /> <br />Roll the vane so that it may be inserted into the hole; do not bend <br />or crease it. Insert the vane so that the arrow on the saddle <br />points in the direction of the waterflow. Install the saddle strap <br />and tighten nuts alternately to an eventual 50 ft-Ibs, (68 n-m) of <br />torque (see Fig. 2). The vane must not rub the inside of the pipe <br />or bind in any way. <br /> <br />Specifications subject to change without notice, <br /> <br />PRINTED IN USA <br /> <br />Potter Electric Signal Company' 2081 Craig Road, SI. Louis, MO, 63146-4161 . Phone: 800-325-3936/Canada 888-882-1833. www.pottersignal.com <br /> <br />PAGE 1 OF 2 <br /> <br />MKT, #8800001 - REV W <br />MFG, #5400761 - 7/02 <br />