My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
08-7402
Zephyrhills
>
Building Department
>
Permits
>
2008
>
08-7402
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/6/2009 4:47:55 PM
Creation date
10/16/2008 10:50:30 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
07-7402
Building Department - Name
NESTLE WATER NA, INC
Address
4330 20TH STREET
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
96
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />@) PQ!!!Jition <br /> <br />FIG. 1 <br />SWITCH TERMINAL <br />CONNECTIONS <br />CLAMPING PLATE <br />TERMINAL <br /> <br />~/ <br /> <br /> <br />G/ <br />()l!IGO'" <br /> <br />owe. ,g2J-] <br /> <br />CAUTION: <br />An un insulated section of a <br />single conductor should not <br />be looped around the termi- <br />nal and serve as two sepa- <br />rate connections. The wire <br />must be severed, thereby <br />providing supervision of the <br />connection in the event that <br />the wire becomes dislodged <br />from under the terminal. <br /> <br />FIG. 2 <br /> <br />VSR-F <br />VANE TYPE WATERFLOW <br />ALARM SWITCH WITH RETARD <br /> <br />OPTIONAL TAMPER SWITCH ~ DO NOT LEAVE COVER OFF FOR <br />~ EXTENDED PERIOD OF TIME <br /> <br /> <br />RETARD ADJUSTMENT: ~ <br />TO CHANGE TIME TURN KNOB (EITHER DIRECTION) .0 <br />FOR DESIRED TIME DELAY. USE THE MINIMUM <br />AMOUNT OF RETARD NECESSARY TO PREVENT <br />FALSE ALARMS. A "S" SETTING IS USUALLY <br />ADEOUATE FOR THIS, FACTORY IS SET TO "S", <br /> <br /> <br />TO INSTALL. DRILL HOLE AS INDICATED: <br />PIPE SIZE HOLE SIZE <br /> <br />2" 10 2 1/2" I 1/4" +1/8" -1/16" <br />(50mm 10 65mm) (33mm i2mm) <br /> <br />3" 10 8" 2" ;'1/8" <br />(80mm 10 20Dmm) 50mm ;,2mm) <br /> <br />Cover Tamper <br />(with cover in place) <br /> <br />n~ <br /> <br />C NO NC <br />(WHT) (RED) (BlK) <br /> <br />DWG. #761-30 <br /> <br />FIG. 3 TYPICAL ELECTRICAL CONNECTIONS <br /> <br />2 SETS Dr <br />NOAMAUY OPEN COHACTS <br />CLOSE ON AlA/h, <br /> <br />rn <br />~ <br /> <br />THE Me '-NO NO ~S <br />ON THE SWITCH ARt fOR <br />MI #tl.JlRW CONDITION. <br />THE CONtACTS ARE: R[\I(RSra <br />"EN THE 0E'o'ICt IS ... <br />THE ~oll CQfOrlOH.. <br /> <br /> <br />NOTES: <br />1. The Model VSR-F has two <br />switches, one can be used to <br />operate a central station, pro- <br />prietary or remote signaling <br />unit, while the other contact is <br />used to operate a local audible <br />or visual annunciator. <br />2, A condition of LPC Approval of <br />this product is that the electri- <br />cal entry must be sealed to <br />exclude moisture. <br />3. For supervised circuits see <br />"Switch Terminal Connec- <br />tions" drawing and caution <br />note (Fig, 1), <br /> <br />TIGHTEN NUTS <br />ALTERNATELY TO AN <br />EVENTUAL 5DFT.-LBS (6B nom) <br />OF TORQUE <br /> <br />MOUNT ON PIPE SO <br />ARROW ON SADDLE <br />POINTS IN DIRECTION <br />OF WATERFLOW <br /> <br />ROLL PADDLE IN <br />OPPOSITE DIRECTION <br />OF WATERFLOW <br /> <br />FIG. 4 <br /> <br />To remove knockouts: Place <br />screwdriver at edge of knock- <br />outs, not in the center. <br /> <br /> <br />APPLICATION WARNING I <br />Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches <br />that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or <br />chemical suppression systems. <br /> <br />TESTING <br />The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in <br />accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends <br />quarterly or more frequently). <br />If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for <br />test purposes. If there are no provisions for testing the operation of the flow detection device on the system, application of the <br />VSR-F is not recommended or advisable, <br />A minimum flow of 10 gpm (38 Lpm) is required to activate this device. <br />IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be <br />tested in accordance with the testing instructions. <br /> <br />PRINTED IN USA <br /> <br />PAGE 2 OF 2 <br /> <br />MKT,#8800001-REVW <br />MFG, #5400761 - 7/02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.