Laserfiche WebLink
uata Zt31 <br /> t I <br /> MOM!, 111.0■11•MM/1■16MMOMMENSIMMO01/aelailmi. <br /> Engineered Systems <br /> •I <br /> IPF Series TM <br /> Dual Point Identification <br /> Device c <br /> • D P 2PID <br /> Description £ <br /> The IP Fire Series'' control system provides for Analog Loop Modules <br /> (ALM's) that may be installed throughout a protected facility in any <br /> number up to the IPF system maximum of 50 modules. IPF Series ' ALM <br /> modules offer analog addressable signaling line (SLC) circuits that may Features <br /> each have up to 126 detectors or 126 addressable control devices in <br /> any combination. ° Dual Class A/B Input Circuits <br /> The AsBuilt Dual Priority Input Device (DXP -2PID) is an addressable • on a Monitors dry d address conta <br /> dual switch monitor that is a means of connecting and identifying two • ry interrupt devices <br /> conventional monitor point circuits at the main IPF Series'' system. DXP- fast as t Priority interrupt feature for <br /> 2PID switch monitors connect to the SLC, are programmed via an 8 pin response <br /> DIL switch (1 -7 for addressing, 8 for Class A/B), are polarity insensitive • Dual LED's visible through the <br /> and are used to monitor one or two Class A or B (Style D or B) circuits. fascia plate label <br /> • Field programmable <br /> The DXP -2PID are designed to monitor the state of one or more single- • Fully supervised <br /> pole, volt -free contacts connected on a single pair of cables on two ° Plate mounted for <br /> separate circuits. <br /> surface/flush mounting in 4" <br /> AsBuilt DXP -2PID switch monitors are available for surface /flush square boxes <br /> mounting in 4" square boxes. ° LED for polling /alarm <br /> 1/ annunciation <br /> DIL switch addressing <br /> In standby mode, the DXP -2PID monitors its internal circuitry for status <br /> of the device itself and supervises both input circuits for faults. In the <br /> event a fault is detected, the DXP -2PID will report a trouble to the IPF <br /> Series ' fire control. <br /> The DXP -2PID incorporates the priority interrupt feature on each of its <br /> two available circuits. Priority interrupt is used where a fast response is <br /> required (as with pull stations). Priority input devices produce output <br /> states of normal, off - normal and alarm. These devices do not produce <br /> pre -alarm output states. <br /> Terminal Block Assignments <br /> TB1 L1 — Loop In /Out Listings <br /> TB5 L2 — Loop In/Out UL File: S7003 <br /> L1 and L2 non - polarized <br /> TB3 Switch Monitor Circuit Class A or B <br /> These devices all use end of line monitoring resistance of 47k' !. <br /> Product Data Sheet Number Rev /Revision Date <br /> IPF Series Dual PID 2816 1.211/1/2009 IP FIRE SERIES <br /> © Copyright 2008 AsBuilt Engineered Systems, Inc. <br />