Laserfiche WebLink
4TIL 73077.02-109-47 <br /> Architectural Testing Page4of7 <br /> Test Specimen Description: (Continued) <br /> Screen Construction: The screen was constructed from extruded aluminum with plastic <br /> comer connectors. <br /> Installation: The flange of the window was set into a #2 Spruce- Pine -Fir wood buck onto a <br /> bed of silicone. The window was secured with #8 x 1 -1/2" flat head screws through the <br /> jambs, head and sill located 4" from each corner and spaced 30" on center. The exterior <br /> perimeter was sealed with silicone. <br /> Test Results: The results are tabulated as follows: <br /> Paragraph Title of Test - Test Method Results Allowed <br /> Test Specimen #1: <br /> 1.4.2.1 Structural Performance Test per ASTM E 330 <br /> (Loads were held for 10 seconds) <br /> 1.4.2.1.1 25.0 psf (positive) No damage No damage <br /> 1.4.2.1.2 12.5 psf (negative) No damage No damage <br /> 1.4.2.2 Air Infiltration Test per ASTM E 283 <br /> 1.57 psf (25 mph) 0.11 cfm/ft 0.5 cfm/ft max. <br /> 1.4.2.3 Water Resistance Test per ASTM E 547 <br /> (with and without insect screen) <br /> 2.86 psf No leakage No leakage <br /> AAMA 1704 -01: <br /> 3.1.1 Clear Opening Width 47 -3/4" 20" <br /> 3.1.2 Clear Opening Height 26 -7/8" 24" <br /> 3.1.3 Clear Opening Area 8.9 ft 5.0 ft <br /> 3.2.1 Locks and Latches 4 lbf 5 lbf <br /> 3.2.2 Operable Sash 15 lbf 20 lbf <br /> 3.2.3 Removable Screen 3 lb 20 lb <br /> S d 4Lbb99LZi`L • N /9L :vI '.LS /BL :bL Boot ZL 2ltlH(nH.L) Wo2ld <br />