Laserfiche WebLink
73077.02 - 109 -47 <br /> Architectural Testing Page 5of7 <br /> Test Results: (Continued) <br /> Paragraph Title of Test - Test Method Results Allowed <br /> Test Specimen #1: (Continued) <br /> Optional Performance: 24 CFR 3280.305 <br /> Uniform Load Structural per ASTM E 330 <br /> (Loads were held for 10 seconds) <br /> 48.0 psf (positive) No damage No damage <br /> 48.0 psf (negative) No damage No damage, <br /> Test Specimen #2: <br /> AAMA 1704 -01: <br /> 3.1.1 Clear Opening Width 31 -1/2" 20" <br /> 3.1.2 Clear Opening Height 26 -7/8" 24" <br /> 3.1.3 Clear Opening Area 5.9 ft 5.0 ft <br /> 3.2.1 Locks and Latches 3 lbf 5 lbf <br /> 3.2.2 Operable Sash 18 lbf 20 lbf <br /> 3.2.3 Removable Screen 2 lb 20 lb <br /> Optional Performance: 24 CFR 3280,305 <br /> Uniform Load Structural per ASTM E 330 <br /> (Loads were held for 10 seconds) <br /> 58.0 psf (positive) No damage No damage <br /> 58.0 psf (negative) No damage No damage. <br /> • <br /> 9 d 8SLZSt''NleL: L'15 /eL: i sooz NVH(flH.L) HO2ld <br />