Laserfiche WebLink
90764.01- 401 -47 <br /> Architectural Testing Page 5 of 10 <br /> Test Results: The temperature during testing was 27 °C (80.6 °F). The results are tabulated as <br /> follows: <br /> Paragraph Title of Test - Test Method Results Allowed <br /> Test Specimen #1: H -LC30 1118 x 1905 (44 x 75) <br /> 5.3.1 Operating Force per ASTM E 2068 <br /> Initiate motion 40 N (9 lbf) Report Only <br /> Maintain motion 36 N (8 lbf) 155 N (35 lbf) <br /> Locks 9 N (2 lbf) 100 N (22.5 lbf) <br /> 5.3.2.1 Air Leakage Resistance per ASTM E 283 <br /> 75 Pa (1.6 psf) 0.25 L /s /m 1.5 L /s /m <br /> (0.05 cfm /ft (0.3 cfm /ft max. <br /> Note #1: The tested specimen meets (or exceeds) the performance levels specified in <br /> AALIA/WDMA /CSA 101 /I.S.2/A440- -05 for air leakage resistance. <br /> 5.3.3.2 Water Penetration Resistance per ASTM E 547 See Note #2 <br /> 5.3.4.2 Uniform Load Deflection per ASTM E 330 See Note #2 <br /> 5.3.4.3 Uniform Load Structural per ASTM E 330 See Note #2 <br /> Note #2: The client opted to start at a pressure higher than the minimum required Those <br /> results are listed under "Optional Performance". <br /> 5.3.5 Forced Entry Resistance per ASTM F 588 <br /> Type: A Grade: 10 <br /> Disassembly Test No entry No entry <br /> Test Al through A7 No entry No entry <br /> Sash Manipulation Test No entry No entry <br /> Lock Hardware Manipulation Test No entry No entry <br /> 5.3.6.2 Thermoplastic Corner Weld Test Meets as stated Meets as stated <br />